Lung nodules: Dual-kilovolt peak analysis with CT - Multicenter study

被引:17
作者
Swensen, SJ
Yamashita, K
McCollough, CH
Viggiano, RW
Midthun, DE
Patz, EF
Muhm, JR
Weaver, AL
机构
[1] Mayo Clin & Mayo Fdn, Dept Diagnost Radiol, Rochester, MN 55905 USA
[2] Mayo Clin & Mayo Fdn, Div Pulm & Crit Care Med, Rochester, MN 55905 USA
[3] Mayo Clin & Mayo Fdn, Biostat Sect, Rochester, MN 55905 USA
[4] Shiga Hlth Insurance Hosp, Dept Diagnost Radiol, Shiga, Japan
[5] Mayo Clin Scottsdale, Div Pulm & Crit Care Med, Scottsdale, AZ USA
[6] Mayo Clin Scottsdale, Dept Diagnost Radiol, Scottsdale, AZ USA
[7] Duke Univ, Med Ctr, Dept Diagnost Radiol, Durham, NC USA
关键词
lung; CT; nodule; lung neoplasms; diagnosis;
D O I
10.1148/radiology.214.1.r00ja2681
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To test the following hypothesis: The greater the increase in the mean computed tomographic (CT) number of a radiologically indeterminate lung nodule from the CT number on a 140-kVp CT image to that on an 80-kVp CT image, the more likely the nodule is benign (ie, contains calcium). MATERIALS AND METHODS: Two hundred forty indeterminate lung nodules were prospectively studied at four institutions: Mayo Clinic Scottsdale, Ariz (n = 160); Mayo Clinic Rochester, Minn (n = 50); Shiga Health insurance Hospital, Otsu, Japan (n = 25); and Duke University Medical Center, Durham, NC (n = 5). Of the 240 nodules, 157 met the entrance criteria for this study and had a diagnosis. All nodules included were solid, 5-40-mm diameter, relatively spherical, homogeneous, and without visible evidence of calcification or fat. Each nodule was evaluated by using 3-mm-collimation, nonenhanced CT scans with both 140- and 80-kVp x-ray beams. RESULTS: There were 86 (55%) benign and 71 (45%) malignant nodules. The median increase in the nodule mean CT number from the CT number on 140-kVp images to that on 80-kVp images was 2 HU for benign nodules and 3 HU for malignant nodules. This difference was not statistically significant. The area under the receiver operating characteristic curve was 0.505. CONCLUSION: Dual-kilovolt peak analysis with current CT technology does not appear to be helpful in the identification of benign lung nodules.
引用
收藏
页码:81 / 85
页数:5
相关论文
共 26 条
[1]  
ATTIX FH, 1986, INTRO RADIOLOGICAL P, P138
[2]   Resection of pulmonary nodules using video-assisted thoracic surgery [J].
Bernard, A ;
Azorin, J ;
Bellenot, F ;
Bonnette, P ;
Brichon, PY ;
Brutus, P ;
Chapelier, A ;
Charpentier, R ;
Dahan, M ;
Dujon, A ;
Escande, G ;
Faillon, MJ ;
Giudicelli, R ;
Grosdidier, G ;
Grunenwald, D ;
Jancovici, R ;
Joyeux, A ;
Meriot, S ;
Monteau, M ;
Moreau, JL ;
Moreau, P ;
Mouroux, J ;
Pouliquen, E ;
Raut, Y ;
Regnard, JF ;
Riquet, M ;
Valverde, JP ;
Velly, JF ;
Wilhm, JM .
ANNALS OF THORACIC SURGERY, 1996, 61 (01) :202-204
[3]   DUAL KV CT TO DETECT CALCIFICATION IN SOLITARY PULMONARY NODULE [J].
BHALLA, M ;
SHEPARD, JO ;
NAKAMURA, K ;
KAZEROONI, EA .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1995, 19 (01) :44-47
[4]   QUANTITATIVE THEORY OF HOUNSFIELD UNIT AND ITS APPLICATION TO DUAL ENERGY SCANNING [J].
BROOKS, RA .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1977, 1 (04) :487-493
[5]   QUANTIFICATION OF CALCIUM IN SOLITARY PULMONARY NODULES USING SINGLE-ENERGY AND DUAL-ENERGY CT [J].
CANN, CE ;
GAMSU, G ;
BIRNBERG, FA ;
WEBB, WR .
RADIOLOGY, 1982, 145 (02) :493-496
[6]  
Curry TI., 1990, CHRISTENSENS PHYS DI, V4, P61
[7]   LOCALIZED BENIGN AND MALIGNANT FIBROUS TUMORS OF THE PLEURA - A CLINICOPATHOLOGIC REVIEW OF 223 CASES [J].
ENGLAND, DM ;
HOCHHOLZER, L ;
MCCARTHY, MJ .
AMERICAN JOURNAL OF SURGICAL PATHOLOGY, 1989, 13 (08) :640-658
[8]   THE SOLITARY CIRCUMSCRIBED PULMONARY NODULE - STUDY OF 705 CASES ENCOUNTERED - ROENTGENOLOGICALLY IN A PERIOD OF 31/2 YEARS [J].
GOOD, CA ;
WILSON, TW .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1958, 166 (03) :210-215
[9]  
GOOD CA, 1963, RADIOL CLIN NORTH AM, V1, P429
[10]   SOLITARY PULMONARY NODULES - DETECTION OF MALIGNANCY WITH PET WITH 2-[F-18]-FLUORO-2-DEOXY-D-GLUCOSE [J].
GUPTA, NC ;
FRANK, AR ;
DEWAN, NA ;
REDEPENNING, LS ;
ROTHBERG, ML ;
MAILLIARD, JA ;
PHALEN, JJ ;
SUNDERLAND, JJ ;
FRICK, MP .
RADIOLOGY, 1992, 184 (02) :441-444