Noninvasive positive-pressure ventilation - An experimental model to assess air and particle dispersion

被引:106
作者
Hui, David S.
Hall, Stephen D.
Chan, Matthew T. V.
Chow, Benny K.
Tsou, Jin Y.
Joynt, Gavin M.
Sullivan, Colin E.
Sung, Joseph J. Y.
机构
[1] Chinese Univ Hong Kong, Dept Med & Therapeut, Shatin, Hong Kong, Peoples R China
[2] Chinese Univ Hong Kong, Dept Anesthesia & Intens Care, Shatin, Hong Kong, Peoples R China
[3] Chinese Univ Hong Kong, Dept Architecture, Shatin, Hong Kong, Peoples R China
[4] Univ New S Wales, Sch Mech Engn, Sydney, NSW, Australia
[5] Univ Sydney, Dept Med, Sydney, NSW 2006, Australia
关键词
air and particle dispersion; influenza; noninvasive positive-pressure ventilation;
D O I
10.1378/chest.130.3.730
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Health-care workers are concerned about the risk of acquiring contagious diseases such as severe acute respiratory syndrome and avian influenza after recent outbreaks. We studied exhaled air and particle dispersion through an oronasal mask attached to a human-patient simulator (HPS) during noninvasive positive-pressure ventilation (NPPV). Methods: Airflow was marked with intrapulmonary smoke for visualization. Therapy with inspiratory positive airway pressure (IPAP) was started at 10 cm H2O and gradually increased to IS cur H2O, whereas expiratory positive airway pressure was maintained at 4 cur H2O. A leakage jet plume was revealed by a laser light sheet and images captured by video. Smoke concentration in the plume was estimated from the light scattered by smoke particles. Findings: A jet plume of air leaked through the mask exhaust holes to a radial distance of 0.25 m from the mask during the application of IPAP at 10 cm H2O with some leakage from the nasal bridge. The leakage plume exposure probability was highest about 60 to 80 mm lateral to the median sagittal plane of the HPS. Without nasal bridge leakage, the jet plume from the exhaust holes increased to a 0.40-m radius from the mask, whereas exposure probability was highest about 0.28 m above the patient. When IPAP was increased to IS cm IPAP the vertical plume extended to 0.45 m above the patient with some horizontal spreading along the ward ceiling. Conclusion: Substantial exposure to exhaled air occurs within a 0.5-m radius of patients receiving NPPV. Medical wards should be designed with an architectural aerodynamics approach and knowledge of air/particle dispersion from common mechanical ventilatory techniques.
引用
收藏
页码:730 / 740
页数:11
相关论文
共 45 条
[11]   Transmission of severe acute respiratory syndrome during intubation and mechanical ventilation [J].
Fowler, RA ;
Guest, CB ;
Lapinsky, SE ;
Sibbald, WJ ;
Louie, M ;
Tang, P ;
Simor, AE ;
Stewart, TE .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2004, 169 (11) :1198-1202
[12]   A model for educational simulation of infant cardiovascular physiology [J].
Godwin, JA ;
van Meurs, WL ;
Couto, CDS ;
Beneken, JEW ;
Graves, SA .
ANESTHESIA AND ANALGESIA, 2004, 99 (06) :1655-1664
[13]   Patient simulation for training basic and advanced clinical skills [J].
Good, ML .
MEDICAL EDUCATION, 2003, 37 :14-21
[14]   Investigation of the secondary corner vortex in a benchmark turbulent backward-facing step using cross-correlation particle imaging velocimetry [J].
Hall, SD ;
Behnia, M ;
Fletcher, CAJ ;
Morrison, GL .
EXPERIMENTS IN FLUIDS, 2003, 35 (02) :139-151
[15]  
HALL SD, 2001, THESIS U NEW S WALES
[16]  
Han Fang, 2004, Sleep Breath, V8, P97, DOI 10.1055/s-2004-829634
[17]   Avian influenza A (H5N1) in 10 patients in Vietnam. [J].
Hien, TT ;
Liem, NT ;
Dung, NT ;
San, LT ;
Mai, PP ;
Chau, NVV ;
Suu, PT ;
Dong, VC ;
Mai, LTQ ;
Thi, NT ;
Khoa, DB ;
Phat, LP ;
Truong, NT ;
Long, HT ;
Tung, CV ;
Giang, LT ;
Tho, ND ;
Nga, LH ;
Tien, NTK ;
San, LH ;
Tuan, LV ;
Dolecek, C ;
Thanh, TT ;
de Jong, M ;
Schultsz, C ;
Cheng, P ;
Lim, W ;
Horby, P ;
Farrar, J .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (12) :1179-1188
[18]   Effect of a nonrebreathing exhalation valve on long-term nasal ventilation using a bilevel device [J].
Hill, NS ;
Carlisle, C ;
Kramer, NR .
CHEST, 2002, 122 (01) :84-91
[19]  
HUANG H, 1994, LIMITATIONS IMPROVEM
[20]   Airflows around oxygen masks - A potential source of infection? [J].
Hui, David S. ;
Ip, Margaret ;
Tang, Julian W. ;
Wong, Alexandra L. N. ;
Chan, Matthew T. V. ;
Hall, Stephen D. ;
Chan, Paul K. S. ;
Sung, Joseph J. Y. .
CHEST, 2006, 130 (03) :822-826