Airborne influenza virus detection with four aerosol samplers using molecular and infectivity assays: considerations for a new infectious virus aerosol sampler

被引:108
作者
Fabian, P. [1 ,3 ]
McDevitt, J. J. [1 ,3 ]
Houseman, E. A. [2 ]
Milton, D. K. [1 ,3 ]
机构
[1] Harvard Univ, Sch Publ Hlth, Dept Environm Hlth, Boston, MA 02115 USA
[2] Harvard Univ, Sch Publ Hlth, Dept Biostat, Boston, MA 02115 USA
[3] Univ Massachusetts, Dept Work Environm, Lowell, MA USA
关键词
Influenza; Air sampler; Biosampler; Compact Cascade Impactor; Teflon filter; Gelatin filter; RELATIVE-HUMIDITY; SERRATIA-MARCESCENS; EXHALED BREATH; AIR SAMPLES; TRANSMISSION; IMPACTION; SENSITIVITY; COLLECTION; SURVIVAL; BACTERIA;
D O I
10.1111/j.1600-0668.2009.00609.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
P>As a first step in conducting studies of airborne influenza transmission, we compared the collection performance of an SKC Biosampler, a compact cascade impactor (CCI), Teflon filters, and gelatin filters by collecting aerosolized influenza virus in a one-pass aerosol chamber. Influenza virus infectivity was determined using a fluorescent focus assay and influenza virus nucleic acid (originating from viable and non-viable viruses) was measured using quantitative PCR. The results showed that the SKC Biosampler recovered and preserved influenza virus infectivity much better than the other samplers - the CCI, Teflon, and gelatin filters recovered only 7-22% of infectious viruses compared with the Biosampler. Total virus collection was not significantly different among the SKC Biosampler, the gelatin, and Teflon filters, but was significantly lower in the CCI. Results from this study show that a new sampler is needed for virus aerosol sampling, as commercially available samplers do not efficiently collect and conserve virus infectivity. Applications for a new sampler include studies of airborne disease transmission and bioterrorism monitoring. Design parameters for a new sampler include high collection efficiency for fine particles and liquid sampling media to preserve infectivity.Practical Implications New air samplers are needed to study infectious airborne viruses and learn about airborne disease transmission. As a first step in designing a new air sampler to collect influenza virus we evaluated four commercial samplers and determined necessary design parameters for a new collector.
引用
收藏
页码:433 / 441
页数:9
相关论文
共 44 条
[21]   AIRBORNE MICRO-ORGANISMS - SURVIVAL TESTS WITH 4 VIRUSES [J].
HARPER, GJ .
JOURNAL OF HYGIENE, 1961, 59 (04) :479-+
[22]   Reduced influenza viral neutralizing activity of natural human trimers of surfactant protein D [J].
Hartshorn, Kevan L. ;
White, Mitchell R. ;
Tecle, Tesfaldet ;
Tornoe, Ida ;
Sorensen, Grith L. ;
Crouch, Erika C. ;
Holmskov, Uffe .
RESPIRATORY RESEARCH, 2007, 8 (1)
[23]   Sampling methodologies and dosage assessment techniques for submicrometre and ultrafine virus aerosol particles [J].
Hogan, CJ ;
Kettleson, EM ;
Lee, MH ;
Ramaswami, B ;
Angenent, LT ;
Biswas, P .
JOURNAL OF APPLIED MICROBIOLOGY, 2005, 99 (06) :1422-1434
[24]   A new method for sampling and detection of exhaled respiratory virus aerosols [J].
Huynh, Kerrianne N. ;
Oliver, Brian G. ;
Stelzer, Sacha ;
Rawlinson, William D. ;
Tovey, Euan R. .
CLINICAL INFECTIOUS DISEASES, 2008, 46 (01) :93-95
[25]   Use of polyurethane foam as the impaction substrate/collection medium in conventional inertial impactors [J].
Kavouras, IG ;
Koutrakis, P .
AEROSOL SCIENCE AND TECHNOLOGY, 2001, 34 (01) :46-56
[26]   Influence of relative humidity on particle size and UV sensitivity of Serratia marcescens and Mycobacterium bovis BCG aerosols [J].
Ko, G ;
First, MW ;
Burge, HA .
TUBERCLE AND LUNG DISEASE, 2000, 80 (4-5) :217-228
[27]   Size and UV germicidal irradiation susceptibility of Serratia marcescens when aerosolized from different suspending media [J].
Lai, KM ;
Burge, HA ;
First, MW .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2004, 70 (04) :2021-2027
[28]   Performance evaluation of commonly used impaction substrates under various loading conditions [J].
Lee, SJ ;
Demokritou, P ;
Koutrakis, P .
JOURNAL OF AEROSOL SCIENCE, 2005, 36 (07) :881-895
[29]   High-throughput, sensitive, and accurate multiplex PCR-microsphere flow Cytometry system for large-scale comprehensive detection of respiratory viruses [J].
Lee, Wai-Ming ;
Grindle, Kris ;
Pappas, Tressa ;
Marshall, David J. ;
Moser, Michael J. ;
Beaty, Edward L. ;
Shult, Peter A. ;
Prudent, James R. ;
Gern, James E. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2007, 45 (08) :2626-2634
[30]   High temperature (30°C) blocks aerosol but not contact transmission of influenza virus [J].
Lowen, Anice C. ;
Steel, John ;
Mubareka, Samira ;
Palese, Peter .
JOURNAL OF VIROLOGY, 2008, 82 (11) :5650-5652