摘要
An automated sample preparation module, based upon sequential injection analysis (SIA), has been developed for use within an autonomous pathogen detection system. The SIA system interfaced aerosol sampling with multiplexed microsphere immunoassay-flow cytometric detection. Metering and sequestering of microspheres using SIA was found to be reproducible and reliable, over 24-h periods of autonomous operation. Four inbuilt immunoassay controls showed excellent immunoassay and system stability over five days of unattended continuous operation. Titration curves for two biological warfare agents, Bacillus anthracis and Yersinia pestis, obtained using the automated SIA procedure were shown to be similar to those generated using a manual microtiter plate procedure.
引用
收藏
页码:3492 / 3497
页数:6
相关论文
共 27 条
[1]  
Bergkvist J, 2002, PROTEOMICS, V2, P422, DOI 10.1002/1615-9861(200204)2:4<422::AID-PROT422>3.0.CO
[2]  
2-1
[3]   Rotating rod renewable microcolumns for automated, solid-phase DNA hybridization studies [J].
Bruckner-Lea, CJ ;
Stottlemyre, MS ;
Holman, DA ;
Grate, JW ;
Brockman, FJ ;
Chandler, DP .
ANALYTICAL CHEMISTRY, 2000, 72 (17) :4135-4141
[4]   Renewable microcolumns for solid-phase nucleic acid separations and analysis from environmental samples [J].
Chandler, DP ;
Brockman, FJ ;
Holman, DA ;
Grate, JW ;
Bruckner-Lea, CJ .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2000, 19 (05) :314-321
[5]  
DAVIDSON JW, UCLRLJC149311EXTABS
[6]   Sequential injection renewable separation column instrument for automated sorbent extraction separations of radionuclides [J].
Egorov, O ;
O'Hara, MJ ;
Grate, JW ;
Ruzicka, J .
ANALYTICAL CHEMISTRY, 1999, 71 (02) :345-352
[7]  
Ekström S, 2002, PROTEOMICS, V2, P413, DOI 10.1002/1615-9861(200204)2:4<413::AID-PROT413>3.0.CO
[8]  
2-1
[9]   Automated sample preparation method for suspension arrays using renewable surface separations with multiplexed flow cytometry fluorescence detection [J].
Grate, JW ;
Bruckner-Lea, CJ ;
Jarrell, AE ;
Chandler, DP .
ANALYTICA CHIMICA ACTA, 2003, 478 (01) :85-98
[10]  
HALLBORN J, 2002, BIOTECHNIQUES, V33, pS30