A wavelet-based ECG delineator:: Evaluation on standard databases

被引:1092
作者
Martínez, JP
Almeida, R
Olmos, S
Rocha, AP
Laguna, P
机构
[1] Univ Zaragoza, Aragon Inst Engn Res, Commun Technol Grp, Zaragoza 50015, Spain
[2] Univ Porto, Fac Ciencias, Dept Matemat Aplicada, P-4169007 Oporto, Portugal
[3] Univ Zaragoza, Aragon Inst Engn Res, Commun Technol Grp, Zaragoza, Spain
关键词
ECG wave delineation; P wave; QRS detection; T wave; wavelets;
D O I
10.1109/TBME.2003.821031
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this paper, we developed and evaluated a robust single-lead electrocardiogram (ECG) delineation system based on the wavelet transform (WT). In a first step, QRS complexes are detected. Then, each QRS is delineated by detecting and identifying the peaks of the individual waves, as well as the complex onset and end. Finally, the determination of P and T wave peaks, onsets and ends is performed. We evaluated the algorithm on several manually annotated databases, such as MIT-BIH Arrhythmia, QT, European ST-T and CSE databases, developed for validation purposes. The QRS detector obtained a sensitivity of Se = 99.66% and a positive predictivity of P+ = 99.56% over the first lead of the validation databases (more than 980,000 beats), while for the well-known MIT-BIH Arrhythmia Database, Se and P+ over 99.8% were attained. As for the delineation of the ECG waves, the mean and standard deviation of the differences between the automatic and manual annotations were computed. The mean error obtained with the WT approach was found not to exceed one sampling interval, while,the standard deviations were around the accepted tolerances between expert physicians, outperforming the results of other well known algorithms, especially in determining the end of T wave.
引用
收藏
页码:570 / 581
页数:12
相关论文
共 48 条
[1]   ECG beat detection using filter banks [J].
Afonso, VX ;
Tompkins, WJ ;
Nguyen, TQ ;
Luo, S .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1999, 46 (02) :192-202
[2]  
AKAY M, 1996, DETECTION ESTIMATION
[3]  
Algra A., 1987, Computers in Cardiology (Cat. No.CH2476-0), P117
[4]  
[Anonymous], 1985, Eur Heart J, V6, P815
[5]  
[Anonymous], 1990, Proceedings Computers in Cardiology
[6]   DSP implementation of wavelet transform for real time ECG wave forms detection and heart rate analysis [J].
Bahoura, M ;
Hassani, M ;
Hubin, M .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1997, 52 (01) :35-44
[7]   Modelling T-end in Holter ECGs by 2-layer perceptrons [J].
Bystricky, W ;
Safer, A .
COMPUTERS IN CARDIOLOGY 2002, VOL 29, 2002, 29 :105-108
[8]   Automatic P-wave analysis of patients prone to atrial fibrillation [J].
Clavier, L ;
Boucher, JM ;
Lepage, R ;
Blanc, JJ ;
Cornily, JC .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2002, 40 (01) :63-71
[9]   Wavelets: The mathematical background [J].
Cohen, A ;
Kovacevic, J .
PROCEEDINGS OF THE IEEE, 1996, 84 (04) :514-522
[10]   Developments in ECG acquisition, preprocessing, parameter measurement, and recording [J].
Daskalov, IK ;
Dotsinsky, IA ;
Christov, II .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1998, 17 (02) :50-58