Evaluation of the THRESHOLD(R) trainer for inspiratory muscle endurance training: Comparison with the weighted plunger method

被引:32
作者
Johnson, PH [1 ]
Cowley, AJ [1 ]
Kinnear, WJM [1 ]
机构
[1] UNIV NOTTINGHAM HOSP,DEPT RESP MED,NOTTINGHAM NG7 2UH,ENGLAND
关键词
respiratory muscles; threshold loading; training; weighted plunger;
D O I
10.1183/09031936.96.09122681
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Inspiratory muscle training (IMT) has been shown to enhance exercise performance. The weighted plunger (WP) system of inspiratory threshold loading is the most commonly used method of IMT, but is expensive and cumbersome. We have evaluated a commercially available portable spring-loaded IMT device, the THRESHOLD(R) trainer. The WP and THRESHOLD(R) trainer devices were evaluated with their opening pressures set, in random order, at 10, 20, 30 and 40 cmH(2)O. Using an air-pump, pressure at the valve inlet was recorded at the point at which the valve opened, and at airflow rates of 20, 40, 60, 80 and 100 L . min(-1). Ten THRESHOLD(R) trainers were then compared using the same opening pressures and airflow rates, Finally, 10 patients with stable chronic heart failure (CHF) inspired, in random order, through the WP and THRESHOLD(R) trainer for 4 min each. The pressure-time product (PTP) was calculated for each 4 min period, to compare the work performed on inspiring through each device. The mean measured opening pressures for the WP set at 10, 20, 30 and 40 cmH(2)O, were 9.0, 19.3, 27.9 and 39.2 cmH(2)O, respectively, and there was little change over the range of flow tested. Corresponding values for the THRESHOLD(R) trainer were 7.5, 16.9, 26.2 and 39.1 cmH(2)O, with the pressure being closer to the set pressure as now increased to that seen in clinical practice. The 10 different trainers tested performed very similarly to one another. Work performed (as measured by PTP) on inspiring through the WP and THRESHOLD(R) trainer was not significantly different. Although less accurate than the weighted plunger, the THRESHOLD(R) trainer is an inexpensive device of consistent quality. In a clinical setting it would be a satisfactory option for inspiratory muscle training in most patients, but less so in patients with very low inspiratory flow rates.
引用
收藏
页码:2681 / 2684
页数:4
相关论文
共 11 条
[1]   MEASUREMENT OF INSPIRATORY MUSCLE PERFORMANCE WITH INCREMENTAL THRESHOLD LOADING - A COMPARISON OF 2 TECHNIQUES [J].
BARDSLEY, PA ;
BENTLEY, S ;
HALL, HS ;
SINGH, SJ ;
EVANS, DH ;
MORGAN, MDL .
THORAX, 1993, 48 (04) :354-359
[2]   A THRESHOLD LOADING DEVICE FOR TESTING OF INSPIRATORY MUSCLE PERFORMANCE [J].
EASTWOOD, PR ;
HILLMAN, DR .
EUROPEAN RESPIRATORY JOURNAL, 1995, 8 (03) :463-466
[3]   VENTILATORY RESPONSES TO INSPIRATORY THRESHOLD LOADING AND ROLE OF MUSCLE FATIGUE IN TASK FAILURE [J].
EASTWOOD, PR ;
HILLMAN, DR ;
FINUCANE, KE .
JOURNAL OF APPLIED PHYSIOLOGY, 1994, 76 (01) :185-195
[4]   SUSTAINED MAXIMUM VOLUNTARY VENTILATION [J].
FREEDMAN, S .
RESPIRATION PHYSIOLOGY, 1970, 8 (02) :230-&
[5]   INSPIRATORY MUSCLE TRAINING - WHERE ARE WE [J].
GOSSELINK, R ;
DECRAMER, M .
EUROPEAN RESPIRATORY JOURNAL, 1994, 7 (12) :2103-2105
[6]   INSPIRATORY MUSCLE TRAINING IN CHRONIC AIR-FLOW LIMITATION - COMPARISON OF 2 DIFFERENT TRAINING LOADS WITH A THRESHOLD DEVICE [J].
LISBOA, C ;
MUNOZ, V ;
BEROIZA, T ;
LEIVA, A ;
CRUZ, E .
EUROPEAN RESPIRATORY JOURNAL, 1994, 7 (07) :1266-1274
[7]   EVIDENCE OF REDUCED RESPIRATORY MUSCLE ENDURANCE IN PATIENTS WITH HEART-FAILURE [J].
MANCINI, DM ;
HENSON, D ;
LAMANCA, J ;
LEVINE, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (04) :972-981
[8]   COMPARISON OF 2-MINUTE INCREMENTAL THRESHOLD LOADING AND MAXIMAL LOADING AS MEASURES OF RESPIRATORY MUSCLE ENDURANCE [J].
MCELVANEY, G ;
FAIRBARN, MS ;
WILCOX, PG ;
PARDY, RL .
CHEST, 1989, 96 (03) :557-563
[9]   RESPIRATORY MUSCLE PERFORMANCE IN NORMAL ELDERLY SUBJECTS AND PATIENTS WITH COPD [J].
MORRISON, NJ ;
RICHARDSON, J ;
DUNN, L ;
PARDY, RL .
CHEST, 1989, 95 (01) :90-94
[10]   MEASURING VENTILATORY MUSCLE ENDURANCE IN HUMANS AS SUSTAINABLE INSPIRATORY PRESSURE [J].
NICKERSON, BG ;
KEENS, TG .
JOURNAL OF APPLIED PHYSIOLOGY, 1982, 52 (03) :768-772