Preoperative examination of potential renal transplant donors: Value of gadolinium-enhanced 3D-MR-Angiography in comparison with DSA and urography.

被引:19
作者
Winterer, JT
Strey, C
Wolffram, C
Paul, G
Einert, A
Altehoefer, C
Uhrmeister, P
Kirste, G
Laubenberger, J
机构
[1] Univ Freiburg, Radiol Klin, Rontgendiagnost Abt, D-79106 Freiburg, Germany
[2] Univ Freiburg, Chirurg Klin, D-7800 Freiburg, Germany
[3] Breisgau Klin, Bad Krozingen, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2000年 / 172卷 / 05期
关键词
3D-MR-angiography; transplantation; anatomy; kidneys; arteries; veins; ureter;
D O I
10.1055/s-2000-667
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess a contrast-enhanced standardized MRA protocol for the presurgical evaluation of potential renal transplant donors. Methods: Twenty-three potential donors for renal transplantations were examined with gadolinium-enhanced, two-phase MR angiograms (1.5 T) and DSA/urography for the number of renal arteries, the presence of aberrant arterial and venous branches, renal artery stenoses and anatomy of the renal collecting system and ureters. The diagnostic value was assessed by evaluating different image processing modalities and interobserver variability. Results: Using maximum intensity projections (MIP) together with multiplanar reformatting (MPR), accessory arteries were detected with a sensitivity/specificity of 100%/98%. Depending on diagnostic experience, exclusive evaluation of MIP yielded a sensitivity/specificity of 67-100%/95-100%. Using MIP/MPR, venous depiction was good in 80%, with MIP solely in 30-40%. At least the proximal third of the ureter was visible in 67%. Conclusion: MPR/MIP evaluation of two-phase, contrast-enhanced MRA provides an excellent depiction of renal vessel anatomy for presurgical evaluation of renal transplant donors. Exclusive MIP assessment is less reliable and depends strongly on the examiner's experience. For sufficient visualization of the ureters, either additional measurements or low-dose diuretic injection have to performed.
引用
收藏
页码:449 / 457
页数:9
相关论文
共 29 条
[1]  
ABLES DP, 1978, AM J ROENTGENOL, V131, P813
[2]   Preoperative evaluation of living renal donors with gadolinium-enhanced magnetic resonance angiography [J].
Bakker, J ;
Ligtenberg, G ;
Beek, FJA ;
van Reedt Dortland, RWH ;
Hené, RJ .
TRANSPLANTATION, 1999, 67 (08) :1167-1172
[3]   THE LIVING DONOR IN KIDNEY-TRANSPLANTATION [J].
BAY, WH ;
HEBERT, LA .
ANNALS OF INTERNAL MEDICINE, 1987, 106 (05) :719-727
[4]   EVALUATION OF LIVING RENAL DONORS - THE CURRENT PRACTICE OF US TRANSPLANT CENTERS [J].
BIA, MJ ;
RAMOS, EL ;
DANOVITCH, GM ;
GASTON, RS ;
HARMON, WE ;
LEICHTMAN, AB ;
LUNDIN, PA ;
NEYLAN, J ;
KASISKE, BL .
TRANSPLANTATION, 1995, 60 (04) :322-327
[5]   Renal artery stenosis: Evaluation with breath-hold, three-dimensional, dynamic, gadolinium-enhanced versus three-dimensional, phase-contrast MR angiography [J].
DeCobelli, F ;
Vanzulli, A ;
Sironi, S ;
Mellone, R ;
Angeli, E ;
Venturini, M ;
Garancini, MP ;
Quartagno, R ;
Bianchi, G ;
DelMaschio, A .
RADIOLOGY, 1997, 205 (03) :689-695
[6]  
DERAUF B, 1987, RADIOL CLIN N AM, V25, P261
[7]   100 LIVING-RELATED KIDNEY DONOR EVALUATIONS USING DIGITAL SUBTRACTION ANGIOGRAPHY [J].
FLECHNER, SM ;
SANDLER, CM ;
HOUSTON, GK ;
VANBUREN, CT ;
LORBER, MI ;
KAHAN, BD .
TRANSPLANTATION, 1985, 40 (06) :675-678
[8]   Evaluating patients with renal failure for renal artery stenosis with gadolinium-enhanced magnetic resonance angiography [J].
Ghantous, VE ;
Eisen, TD ;
Sherman, AH ;
Finkelstein, FO .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1999, 33 (01) :36-42
[9]   Renal artery stenosis: Evaluation with conventional angiography versus gadolinium-enhanced MR angiography [J].
Gilfeather, M ;
Yoon, HC ;
Siegelman, ES ;
Axel, L ;
Stolpen, AH ;
Shlansky-Goldberg, RD ;
Baum, RA ;
Soulen, MC ;
Schnall, MD .
RADIOLOGY, 1999, 210 (02) :367-372
[10]   Renal MR angiography at 1.0 T:: Three-dimensional (3D) phase-contrast techniques versus gadolinium-enhanced 3D fast low-angle shot breath-hold imaging [J].
Hahn, U ;
Miller, S ;
Nägele, T ;
Schick, F ;
Erdtmann, B ;
Duda, S ;
Claussen, CD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (06) :1501-1508