Renal artery stenosis: Evaluation with breath-hold, three-dimensional, dynamic, gadolinium-enhanced versus three-dimensional, phase-contrast MR angiography

被引:84
作者
DeCobelli, F
Vanzulli, A
Sironi, S
Mellone, R
Angeli, E
Venturini, M
Garancini, MP
Quartagno, R
Bianchi, G
DelMaschio, A
机构
[1] SAN RAFFAELE SCI INST,UNIV HOSP,DEPT EPIDEMIOL,I-20132 MILAN,ITALY
[2] SAN RAFFAELE SCI INST,UNIV HOSP,DEPT NEPHROL,I-20132 MILAN,ITALY
关键词
gadolinium; magnetic resonance (MR); contrast enhancement; phase imaging; three-dimensional; vascular studies; renal arteries; MR; stenosis or obstruction;
D O I
10.1148/radiology.205.3.9393522
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare breath-hold, three-dimensional, gadolinium-enhanced magnetic resonance (MR) angiography with three-dimensional, phase-contrast MR angiography in the evaluation of renal artery stenosis. MATERIALS AND METHODS: Fifty-five consecutive adult patients with clinical suspicion of renovascular disease were prospectively examined with three-dimensional, phase-contrast MR angiography and breath-hold, three-dimensional MR angiography with injection of a standard dose of gadopentetate dimeglumine to evaluate the number of renal arteries and the presence and degree of stenosis. The standard of reference was intraarterial digital subtraction angiography. RESULTS: Gadolinium-enhanced MR angiography depicted all 105 main renal arteries, whereas phase-contrast MR angiography depicted 104. The number of accessory renal arteries depicted was significantly higher with gadolinium-enhanced (17 of 18) than with phase-contrast (11 of 18) studies (P = .04). Both techniques depicted 27 of the 29 stenoses (sensitivity, 93%; P > .05). Sensitivities, specificities, and accuracies in the diagnosis of hemodynamically significant stenosis (> 50% narrowing) were, respectively, 94%, 96%, and 96% for phase-contrast and 100%, 97%, and 98% for gadolinium-enhanced MR angiography (P > .05). CONCLUSION: Gadolinium-enhanced MR angiography is superior to phase-contrast MR angiography in accessory renal artery depiction. No statistically significant difference in the assessment of stenosis has been found between the two techniques.
引用
收藏
页码:689 / 695
页数:7
相关论文
共 24 条
  • [1] Treatment of ostial renal-artery stenoses with vascular endoprostheses after unsuccessful balloon angioplasty
    Blum, U
    Krumme, B
    Flugel, P
    Gabelmann, A
    Lehnert, T
    BuitragoTellez, C
    Schollmeyer, P
    Langer, M
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (07) : 459 - 465
  • [2] RENAL-ARTERIES - CLINICAL COMPARISON OF 3-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHIC SEQUENCES AND RADIOGRAPHIC ANGIOGRAPHY
    BORRELLO, JA
    LI, DB
    VESELY, TM
    VINING, EP
    BROWN, JJ
    HAACKE, EM
    [J]. RADIOLOGY, 1995, 197 (03) : 793 - 799
  • [3] Carriero A, 1994, Radiol Med, V87, P254
  • [4] IMAGING OF THE RENAL-ARTERIES - VALUE OF MR ANGIOGRAPHY
    DEBATIN, JF
    SPRITZER, CE
    GRIST, TM
    BEAM, C
    SVETKEY, LP
    NEWMAN, GE
    SOSTMAN, HD
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (05) : 981 - 990
  • [5] Renal artery stenosis: Value of screening with three-dimensional phase-contrast MR angiography with a phased-array multicoil
    DeCobelli, F
    Mellone, R
    Salvioni, M
    Vanzulli, A
    Sironi, S
    Manunta, P
    Lanzani, C
    Bianchi, G
    DelMaschio, A
    [J]. RADIOLOGY, 1996, 201 (03) : 697 - 703
  • [6] Renovascular disease in patients with hypertension: Detection with systolic and diastolic gating in three-dimensional, phase-contrast MR angiography
    deHaan, MW
    Kouwenhoven, M
    Thelissen, GRP
    Koster, D
    Kessels, AGH
    deLeeuw, PW
    vanEngelshoven, JMA
    [J]. RADIOLOGY, 1996, 198 (02) : 449 - 456
  • [7] Hepatic arterial-phase dynamic gadolinium-enhanced MR imaging: Optimization with a test examination and a power injector
    Earls, JP
    Rofsky, NM
    DeCorato, DR
    Krinsky, GA
    Weinreb, JC
    [J]. RADIOLOGY, 1997, 202 (01) : 268 - 273
  • [8] RENAL-ARTERIES - EVALUATION WITH OPTIMIZED 2D AND 3D TIME-OF-FLIGHT MR-ANGIOGRAPHY
    FELLNER, C
    STROTZER, M
    GEISSLER, A
    KOHLER, SM
    KRAMER, BK
    SPIES, V
    HELD, P
    GMEINWIESER, J
    [J]. RADIOLOGY, 1995, 196 (03) : 681 - 687
  • [9] BREATH-HOLDING CAPABILITY OF ADULTS - IMPLICATIONS FOR SPIRAL COMPUTED-TOMOGRAPHY, FAST-ACQUISITION MAGNETIC-RESONANCE-IMAGING, AND ANGIOGRAPHY
    GAY, SB
    SISTROM, CL
    HOLDER, CA
    SURATT, PM
    [J]. INVESTIGATIVE RADIOLOGY, 1994, 29 (09) : 848 - 851
  • [10] GEDROYC WMW, 1994, UROL CLIN N AM, V21, P201