Renal artery stenosis: Value of screening with three-dimensional phase-contrast MR angiography with a phased-array multicoil

被引:38
作者
DeCobelli, F [1 ]
Mellone, R [1 ]
Salvioni, M [1 ]
Vanzulli, A [1 ]
Sironi, S [1 ]
Manunta, P [1 ]
Lanzani, C [1 ]
Bianchi, G [1 ]
DelMaschio, A [1 ]
机构
[1] UNIV HOSP, SCI INST H S RAFFAELE, DEPT NEPHROL, I-20132 MILAN, ITALY
关键词
D O I
10.1148/radiology.201.3.8939218
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate screening with three-dimensional (3D) phase-contrast magnetic resonance (MR) angiography with a phased-array multicoil to detect renal artery stenosis. MATERIALS AND METHODS: Fifty consecutive patients suspected of having renovascular disease were prospectively examined with 3D phase-contrast MR imaging with a phased-array multicoil. Findings were correlated with those at intraarterial digital subtraction angiography (DSA) as the standard of reference for grade of stenosis. RESULTS: MR angiography depicted 101 of 103 renal arteries depicted at intraarterial DSA; the two missed arteries were an accessory artery outside the imaging volume and an artery with a stent. At intraarterial DSA, a stenosis was found in 31 of 101 arteries. On the basis of findings at 3D phase-contrast MR angiography, the presence of any degree of stenosis was correctly depicted in 29 of 31 cases and the absence of stenosis was correctly depicted in 66 of 70 cases (accuracy, 94%; sensitivity, 94%; negative predictive value, 97%). Overall accuracy was 97% for correct depiction of severe renal artery stenosis (>50%). CONCLUSION: 3D phase-contrast MR angiography with a phased-array multicoil was an accurate noninvasive screening technique in patients with suspected renal artery stenosis.
引用
收藏
页码:697 / 703
页数:7
相关论文
共 42 条
  • [1] [Anonymous], 1987, ARCH INTERN MED, V147, P820
  • [2] RENAL-ARTERIES - CLINICAL COMPARISON OF 3-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHIC SEQUENCES AND RADIOGRAPHIC ANGIOGRAPHY
    BORRELLO, JA
    LI, DB
    VESELY, TM
    VINING, EP
    BROWN, JJ
    HAACKE, EM
    [J]. RADIOLOGY, 1995, 197 (03) : 793 - 799
  • [3] DETECTION OF RENAL-ARTERY STENOSIS WITH DOPPLER SONOGRAPHY - IT IS MORE COMPLICATED THAN ORIGINALLY THOUGHT
    BUDE, RO
    RUBIN, JM
    [J]. RADIOLOGY, 1995, 196 (03) : 612 - 613
  • [4] MR-IMAGING OF THE ABDOMEN WITH A PHASED-ARRAY MULTICOIL - PROSPECTIVE CLINICAL-EVALUATION
    CAMPEAU, NG
    JOHNSON, CD
    FELMLEE, JP
    RYDBERG, JN
    BUTTS, RK
    EHMAN, RL
    RIEDERER, SJ
    [J]. RADIOLOGY, 1995, 195 (03) : 769 - 776
  • [5] RENAL SCINTIGRAPHY VERSUS RENAL-VEIN RENIN-ACTIVITY FOR IDENTIFYING AND TREATING RENOVASCULAR HYPERTENSION
    CHIARINI, C
    ESPOSTI, ED
    LOSINNO, F
    MONETTI, N
    PAVLICA, P
    SANTORO, A
    STURANI, A
    VECCHI, F
    ZUCCALA, A
    ZUCCHELLI, P
    [J]. NEPHRON, 1982, 32 (01): : 8 - 13
  • [6] RENAL-ARTERY BLOOD-FLOW - QUANTITATION WITH PHASE-CONTRAST MR-IMAGING WITH AND WITHOUT BREATH-HOLDING
    DEBATIN, JF
    TING, RH
    WEGMULLER, H
    SOMMER, FG
    FREDRICKSON, JO
    BROSNAN, TJ
    BOWMAN, BS
    MYERS, BD
    HERFKENS, RJ
    PELC, NJ
    [J]. RADIOLOGY, 1994, 190 (02) : 371 - 378
  • [7] IMAGING OF THE RENAL-ARTERIES - VALUE OF MR ANGIOGRAPHY
    DEBATIN, JF
    SPRITZER, CE
    GRIST, TM
    BEAM, C
    SVETKEY, LP
    NEWMAN, GE
    SOSTMAN, HD
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (05) : 981 - 990
  • [8] Renovascular disease in patients with hypertension: Detection with systolic and diastolic gating in three-dimensional, phase-contrast MR angiography
    deHaan, MW
    Kouwenhoven, M
    Thelissen, GRP
    Koster, D
    Kessels, AGH
    deLeeuw, PW
    vanEngelshoven, JMA
    [J]. RADIOLOGY, 1996, 198 (02) : 449 - 456
  • [9] DONDI M, 1992, J NUCL MED, V33, P2040
  • [10] RENAL-ARTERIES - EVALUATION WITH OPTIMIZED 2D AND 3D TIME-OF-FLIGHT MR-ANGIOGRAPHY
    FELLNER, C
    STROTZER, M
    GEISSLER, A
    KOHLER, SM
    KRAMER, BK
    SPIES, V
    HELD, P
    GMEINWIESER, J
    [J]. RADIOLOGY, 1995, 196 (03) : 681 - 687