An impedimetric immunosensor for the detection of autoantibodies directed against gliadins

被引:37
作者
Balkenhohl, T. [1 ]
Lisdat, F. [1 ]
机构
[1] Univ Appl Sci Wildau, D-15745 Wildau, Germany
关键词
D O I
10.1039/b609832k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An immunosensor has been developed for the detection of autoantibodies directed against wheat gliadin, a protein fraction of cereal gluten which is involved in celiac disease. The immunosensor is based on the immobilization of gliadins onto gold electrodes covered with a polyelectrolyte layer of poly(4-styrenesulfonic acid sodium salt). The immobilization was monitored by quartz crystal microbalance (QCM) analysis. The antigen - antibody interaction signal was amplified by an incubation step with peroxidase-labeled immunoglobulins and subsequent peroxidase-catalyzed oxidation of 3-amino-9-ethylcarbazole (AEC). Changes in the insulating properties of the electrode layer were measured by electrochemical impedance spectroscopy ( EIS) in the presence of ferri/ferro-cyanide. Impedance spectra could be fitted to a Randles equivalent circuit with high accuracy. Exposing the sensor electrodes to various antigliadin antibody concentrations resulted in proportional changes in the charge transfer resistance. A calibration graph for the detection of antigliadin antibodies was established for antibody concentrations between 10(-8) and 10(-6) M. Finally, the sensor was used for the determination of antigliadin autoantibodies of the IgG and IgA type in several human sera.
引用
收藏
页码:314 / 322
页数:9
相关论文
共 43 条
[1]   A superoxide sensor based on a multilayer cytochrome c electrode [J].
Beissenhirtz, MK ;
Scheller, FW ;
Lisdat, F .
ANALYTICAL CHEMISTRY, 2004, 76 (16) :4665-4671
[2]  
BRADFORD MM, 1976, ANAL BIOCHEM, V72, P248, DOI 10.1016/0003-2697(76)90527-3
[3]   An integrated electrochemical fructose biosensor based on tetrathiafulvalene-modified self-assembled monolayers on gold electrodes [J].
Campuzano, S ;
Gaálvez, R ;
Pedrero, M ;
Manuel de Villena, FJ ;
Pingarrón, JM .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (04) :600-607
[4]   Characterization of polyelectrolyte-protein multilayer films by atomic force microscopy, scanning electron microscopy, and Fourier transform infrared reflection-absorption spectroscopy [J].
Caruso, F ;
Furlong, DN ;
Ariga, K ;
Ichinose, I ;
Kunitake, T .
LANGMUIR, 1998, 14 (16) :4559-4565
[5]   Protein adsorption to organosiloxane surfaces studied by acoustic wave sensor [J].
Cavic, BA ;
Thompson, M .
ANALYST, 1998, 123 (10) :2191-2196
[6]   Impedimetric immunosensors based on the conjugated polymer PPV [J].
Cooreman, P ;
Thoelen, R ;
Manca, J ;
vandeVen, M ;
Vermeeren, V ;
Michiels, L ;
Ameloot, A ;
Wagner, P .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (10) :2151-2156
[7]  
Cousino MA, 1997, ANN CHIM-ROME, V87, P93
[8]   Development of an immunosensor for the detection of vitellogenin using impedance spectroscopy [J].
Darain, F ;
Park, DS ;
Park, JS ;
Shim, YB .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (10) :1245-1252
[9]   Enzyme-catalyzed amplified immunoassay for the detection of Toxoplasma gondii-specific IgG using Faradaic impedance spectroscopy, CV and QCM [J].
Ding, YJ ;
Wang, H ;
Shen, GL ;
Yu, RQ .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (07) :1491-1499
[10]   Multilayer polyelectrolyte films functionalized by insertion of defensin: A new approach to protection of implants from bacterial colonization [J].
Etienne, O ;
Picart, C ;
Taddei, C ;
Haikel, Y ;
Dimarcq, JL ;
Schaaf, P ;
Voegel, JC ;
Ogier, JA ;
Egles, C .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2004, 48 (10) :3662-3669