A multilayer optical test strip for copper determination in human plasma

被引:2
作者
Capitán-Vallvey, LF
Cano-Raya, C
del Valle, CE
Ramos, MDF
de Orbe-Payá, I
Avidad, R
González, VR
机构
[1] Univ Granada, Dept Analyt Chem, E-18071 Granada, Spain
[2] Univ Granada, Dept Appl Math, E-18071 Granada, Spain
关键词
copper determination; strip test; single-use optical sensor; human plasma analysis;
D O I
10.1081/AL-120003165
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new procedure to determine copper has been proposed using an irreversible and disposable multilayer optical test strip. Two layers form the sensing zone: a copper sensitive and a dialysis layer. The test strip is characterised to be a disposable polyester sheet contained in a circular film 6 mm in diameter and 25 mum in thickness, with all reagents necessary to produce a selective response. The sensing zone was formed by Nafion as polymer, bathocuproine as a chromogenic reagent and p-anisidine as reducer. When it is applied to determination of copper in plasma samples, another layer of hydrogel D-6 is put on this membrane to eliminate the interference of proteins. When the test strip was introduced for 60 min into a plasma sample an orange colour developed. The absorbance at 475 nm was used as the analytical signal. The test strip responded linearly in the range 0.05-1.00 mg L-1. The reproducibility in the measurement of copper at 3.0 mg L-1, was 7.8%. The procedure was applied to the determination of copper in different samples of plasma validating results against a reference method used in clinical laboratory. The method is simple, inexpensive, selective and sensitive.
引用
收藏
页码:615 / 633
页数:19
相关论文
共 39 条
  • [21] ISAACSON E, 1966, ANAL NUMERICAL METHO, P295
  • [22] Multilayer potassium sensor based on solid-state coextraction
    Krause, C
    Werner, T
    Wolfbeis, OS
    [J]. ANALYTICAL SCIENCES, 1998, 14 (01) : 163 - 167
  • [23] The urine test strip of the future
    Kutter, D
    [J]. CLINICA CHIMICA ACTA, 2000, 297 (1-2) : 297 - 304
  • [24] LUO S, 2000, Patent No. 6051437
  • [25] Malçik N, 2000, QUIM ANAL, V19, P94
  • [26] MARCZENKO Z, 1986, SEPARATION SPECTROPH, P262
  • [27] LED-COMPATIBLE COPPER(II)-SELECTIVE OPTRODE MEMBRANE-BASED ON LIPOPHILIZED ZINCON
    OEHME, I
    PROKES, B
    MURKOVIC, I
    WERNER, T
    KLIMANT, I
    WOLFBEIS, OS
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 350 (7-9): : 563 - 567
  • [28] Optical sensors for determination of heavy metal ions
    Oehme, I
    Wolfbeis, OS
    [J]. MIKROCHIMICA ACTA, 1997, 126 (3-4) : 177 - 192
  • [29] POPPE W, 1986, Patent No. 4592893
  • [30] PRZYBYLOWICZ EP, 1976, Patent No. 3992158