Pulmonary Embolism Detection with Dual-Energy CT: Experimental Study of Dual-Source CT in Rabbits

被引:97
作者
Zhang, Long-Jiang [1 ]
Zhao, Yan-E [1 ]
Wu, Sheng-Yong [3 ]
Yeh, Benjamin M. [2 ]
Zhou, Chang-Sheng [1 ]
Hu, Xiao-Bo [1 ]
Hu, Qiu-Ju [1 ]
Lu, Guang-Ming [1 ]
机构
[1] Nanjing Univ, Jinling Hosp, Dept Med Imaging, Sch Clin,Coll Med, Nanjing 200012, Jiangsu, Peoples R China
[2] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
[3] Med Imaging Inst Tianjin, Tianjin, Peoples R China
关键词
COMPUTED-TOMOGRAPHY PERFUSION; CORONARY-ARTERY-DISEASE; MULTIDETECTOR-ROW CT; ELECTRON-BEAM CT; INITIAL-EXPERIENCE; LUNG PERFUSION; PORCINE MODEL; DIAGNOSTIC-ACCURACY; BLOOD-FLOW; VISUALIZATION;
D O I
10.1148/radiol.2521081682
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate feasibility and added value of dual-energy computed tomography (CT) in diagnosis of pulmonary embolism (PE). Materials and Methods: This institutional animal experimental committee-approved study was performed in accordance with animal care guidelines. Eight New Zealand rabbits underwent standard unenhanced and contrast material-enhanced dual-source CT. Gelatin sponge particles were injected into the pulmonary artery, and rabbits underwent contrast-enhanced dual- source CT pulmonary angiography, from which blood-flow (BF) and fusion images were created. Immediately after dual- source CT, rabbits were sacrificed, their lungs were removed and fixed in 10% formalin, and detailed pathologic determination of location and number of lung lobes with PE was performed. Two rabbits were excluded: One died during the procedure. In the other, the catheter tip was retained in the left inferior pulmonary artery. This caused marked postembolization CT image artifacts in adjacent regions. Six rabbits were included in final analysis. Two radiologists without knowledge of pathologic results evaluated five pulmonary lobes in each rabbit and recorded whether PE was present. Pathologic results served as the reference standard. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the techniques were calculated. Weighted kappa values were calculated to evaluate agreement between modalities. Results: Pathologic analysis revealed PE in 18 of 30 pulmonary lobes. Conventional CT angiography was used to correctly identify PE in 12 lobes and absence of emboli in 18 lobes, which corresponded to sensitivity, specificity, PPV, and NPV of 67%, 100%, 100%, and 67%, respectively. A kappa value of 0.65 indicated good correlation with pathologic findings. On BF images, segments with an embolic region showed low perfusion compared with segments with a normal pulmonary region. BF images and fused images correctly showed PE in 16 of 18 pulmonary lobes and absence of emboli in 11 of 12 lobes, which corresponded to sensitivity, specificity, PPV, and NPV of 89%, 92%, 94%, and 85%, respectively, in detection of PE. A kappa value of 0.80 indicated good correlation with pathologic findings. Conclusion: Dual-source CT can depict normal and abnormal blood perfusion distribution in a rabbit's lung. Abnormal pulmonary blood distribution, as shown at dual-source CT, improves detection of acute PE in rabbits.
引用
收藏
页码:61 / 70
页数:10
相关论文
共 40 条
[11]   Computed tomography densitometry of the lung: a method to assess perfusion defects in acute pulmonary embolism [J].
Groell, R ;
Peichel, KH ;
Uggowitzer, MM ;
Schmid, F ;
Hartwagner, K .
EUROPEAN JOURNAL OF RADIOLOGY, 1999, 32 (03) :192-196
[12]   Characterization of human renal stones with MDCT: Advantage of dual energy and limitations due to respiratory motion [J].
Grosjean, Romain ;
Sauer, Benoit ;
Guerra, Rui Matias ;
Daudon, Michel ;
Blum, Alain ;
Felblinger, Jacques ;
Hubert, Jacques .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (03) :720-728
[13]   CT perfusion imaging of the lung in pulmonary embolism [J].
Herzog, P ;
Wildberger, JE ;
Niethammer, M ;
Schaller, S ;
Schoepf, UJ .
ACADEMIC RADIOLOGY, 2003, 10 (10) :1132-1146
[14]   Usefulness of noninvasive cardiac imaging using dual-source computed tomography in an unselected population with high prevalence of coronary artery disease [J].
Heuschmid, Martin ;
Burgstahler, Christof ;
Reimann, Ania ;
Brodoefel, Harald ;
Mysal, Ines ;
Haeberle, Ellen ;
Tsiflikas, Ilijas ;
Claussen, Claus D. ;
Kopp, Andreas F. ;
Schroeder, Stephen .
AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (04) :587-592
[15]   Diagnosis of pulmonary embolism: Comparison of CT angiography and MR angiography in canines [J].
Hurst, DR ;
Kazerooni, EA ;
Stafford-Johnson, D ;
Williams, DM ;
Platt, JF ;
Cascade, PN ;
Prince, MR .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1999, 10 (03) :309-318
[16]   Diagnostic accuracy of dual-source computed tomography in the diagnosis of coronary artery disease [J].
Johnson, Thorsten R. C. ;
Nikolaou, Konstantin ;
Busch, Stephanie ;
Leber, Alexander W. ;
Becker, Alexander ;
Wintersperger, Bernd J. ;
Rist, Carsten ;
Knez, Andreas ;
Reiser, Maximilian F. ;
Becker, Christoph R. .
INVESTIGATIVE RADIOLOGY, 2007, 42 (10) :684-691
[17]   Material differentiation by dual energy CT: initial experience [J].
Johnson, Thorsten R. C. ;
Krauss, Bernhard ;
Sedlmair, Martin ;
Grasruck, Michael ;
Bruder, Herbert ;
Morhard, Dominik ;
Fink, Christian ;
Weckbach, Sabine ;
Lenhard, Miriam ;
Schmidt, Bernhard ;
Flohr, Thomas ;
Reiser, Maximilian F. ;
Becker, Christoph R. .
EUROPEAN RADIOLOGY, 2007, 17 (06) :1510-1517
[18]   Computed tomography perfusion of the liver: Assessment of pure portal blood flow studied with CT perfusion during superior mesenteric arterial portography [J].
Kojima, H ;
Tanigawa, N ;
Komemushi, A ;
Kariya, S ;
Sawada, S .
ACTA RADIOLOGICA, 2004, 45 (07) :709-715
[19]   Pulmonary embolism: an unsuspected killer [J].
Laack, TA ;
Goyal, DG .
EMERGENCY MEDICINE CLINICS OF NORTH AMERICA, 2004, 22 (04) :961-+
[20]   White matter thresholds for ischemic penumbra and infarct core in patients with acute stroke: CT perfusion study [J].
Murphy, Blake D. ;
Fox, Allan J. ;
Lee, Donald H. ;
Sahlas, Demetrios J. ;
Black, Sandra E. ;
Hogan, Matthew J. ;
Coutts, Shelagh B. ;
Demchuk, Andrew M. ;
Goyal, Mayank ;
Aviv, Richard I. ;
Symons, Sean ;
Gulka, Irene B. ;
Beletsky, Vadim ;
Pelz, David ;
Chan, Richard K. ;
Lee, Ting-Yim .
RADIOLOGY, 2008, 247 (03) :818-825