Effects of mechanical flaws in open-ended coaxial probes for dielectric spectroscopy

被引:17
作者
Popovic, D [1 ]
Okoniewski, M [1 ]
机构
[1] Univ Calgary, Dept Elect & Comp Engn, Calgary, AB T2N 1N4, Canada
关键词
dielectric spectroscopy; mechanical flaws; microwave frequencies; open-ended coaxial probes;
D O I
10.1109/LMWC.2002.803192
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A detailed study of dielectric properties of breast tissue in the 0.1 to 20 GHz frequency range currently under way uses open-ended teflon coaxial probes as sensors. This letter quantifies the effects of small mechanical imperfections at the probe aperture on the measured reflection coefficient. The mechanical flaws in the probe can lead. to significant errors, thus probes. for dielectric spectroscopy of breast tissue have to be carefully manufactured.
引用
收藏
页码:401 / 403
页数:3
相关论文
共 15 条
[1]  
[Anonymous], 589 NBS US DEP COMM
[2]   MEASUREMENT OF RADIO-FREQUENCY PERMITTIVITY OF BIOLOGICAL TISSUES WITH AN OPEN-ENDED COAXIAL LINE .1. [J].
ATHEY, TW ;
STUCHLY, MA ;
STUCHLY, SS .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1982, 30 (01) :82-86
[3]   A comparative study of four open-ended coaxial probe models for permittivity measurements of lossy dielectric biological materials at microwave frequencies [J].
Berube, D ;
Ghannouchi, FM ;
Savard, P .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1996, 44 (10) :1928-1934
[4]   Open-ended metallized ceramic coaxial probe for high-temperature dielectric properties measurements [J].
Bringhurst, S ;
Iskander, MF .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1996, 44 (06) :926-935
[5]   DIELECTRIC-PROPERTIES OF FEMALE HUMAN BREAST-TISSUE MEASURED INVITRO AT 3.2 GHZ [J].
CAMPBELL, AM ;
LAND, DV .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (01) :193-210
[6]  
CHAUDHARY SS, 1984, INDIAN J BIOCHEM BIO, V21, P76
[7]   Microwave detection of breast cancer [J].
Fear, E.C. ;
Stuchly, M.A. .
IEEE Transactions on Microwave Theory and Techniques, 2000, 48 (11 I) :1854-1863
[8]   Three-dimensional FDTD analysis of a pulsed microwave confocal system for breast cancer detection: Design of an antenna-array element [J].
Hagness, SC ;
Taflove, A ;
Bridges, JE .
IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 1999, 47 (05) :783-791
[9]   Two-dimensional FDTD analysis of a pulsed microwave confocal system for breast cancer detection: Fixed-focus and antenna-array sensors [J].
Hagness, SC ;
Taflove, A ;
Bridges, JE .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (12) :1470-1479
[10]   THE MEASURED ELECTRICAL-PROPERTIES OF NORMAL AND MALIGNANT HUMAN TISSUES FROM 50 TO 900 MHZ [J].
JOINES, WT ;
ZHANG, Y ;
LI, CX ;
JIRTLE, RL .
MEDICAL PHYSICS, 1994, 21 (04) :547-550