Root surface removal with diamond-coated ultrasonic instruments: An in vitro and SEM study

被引:12
作者
Lavespere, JE
Yukna, RA
Rice, DA
LeBlanc, DM
机构
[1] LOUISIANA STATE UNIV,SCH DENT,DEPT PERIODONT,NEW ORLEANS,LA 70119
[2] TULANE UNIV,DEPT BIOMED ENGN,NEW ORLEANS,LA 70118
关键词
dental calculus prevention and control; dental instruments; planing/instrumentation; tooth root; dental plaque prevention and control;
D O I
10.1902/jop.1996.67.12.1281
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ADEQUATE ROOT PREPARATION in periodontal procedures includes the removal of plaque, calculus, and perhaps contaminated cementum and dentin. The purpose of this study was to evaluate and compare the amount of root surface removal and residual surface texture using similarly shaped regular (US) and both fine (FINDIAM) and medium (MEDDIAM) grit diamond-coated ultrasonic inserts. Forty-five (45) premolars extracted for orthodontic reasons were randomly divided into 3 groups of 15 teeth each. They were individually mounted in a jig and instrumented with a standardized 500 gram force while they were moved a precise horizontal distance of 12 mm over a 1.2 second period using specially designed and computer controlled instrumentation. Three measurements were made to the nearest 0.0005 '' at 3 points along the test area before instrumentation and after 10 and 20 strokes. The mean depth of root structure removed was US 5.8 +/- 6.6 mu m, FINDIAM 50.1 +/- 14.2 mu m, MEDDIAM 30.8 +/- 12.1 mu m, after 10 strokes, and US 12.7 +/- 10.9 mu m, FINDIAM 83.3 +/- 20.1 mu m, MEDDIAM 58.7 +/- 17.9 mu m after 20 strokes, respectively. All 3 instruments were different from each other (P < 0.001) in the 10 stroke group, while in the 20 stroke group FINDIAM and MEDDIAM were different from US (P < 0.001), but not from each other. Only FINDIAM showed a significant difference between 10 and 20 stroke values for depth of root removal. Modified loss of tooth substance index SEM scores indicated increasingly greater root surface roughness from US to FINDIAM to MEDDIAM. Substantially greater root surface removal and greater residual root surface roughness occurred with diamond-coated ultrasonic inserts under standardized in vitro conditions. These results suggest that caution should be used with diamond-coated ultrasonic instruments during periodontal root planing procedures.
引用
收藏
页码:1281 / 1287
页数:7
相关论文
共 51 条
[31]   CEMENTAL RESPONSE TO ULTRASONIC + HAND INSTRUMENTATION [J].
MOSKOW, BS ;
BRESSMAN, E .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1964, 68 (05) :698-&
[32]   ROLE OF DISEASED ROOT CEMENTUM IN HEALING FOLLOWING TREATMENT OF PERIODONTAL-DISEASE - AN EXPERIMENTAL-STUDY IN THE DOG [J].
NYMAN, S ;
SARHED, G ;
ERICSSON, I ;
GOTTLOW, J ;
KARRING, T .
JOURNAL OF PERIODONTAL RESEARCH, 1986, 21 (05) :496-503
[33]   ROLE OF DISEASED ROOT CEMENTUM IN HEALING FOLLOWING TREATMENT OF PERIODONTAL-DISEASE - A CLINICAL-STUDY [J].
NYMAN, S ;
WESTFELT, E ;
SARHED, G ;
KARRING, T .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1988, 15 (07) :464-468
[34]   TOTAL CEMENTUM REMOVAL - A REALISTIC OBJECTIVE [J].
OLEARY, TJ ;
KAFRAWY, AH .
JOURNAL OF PERIODONTOLOGY, 1983, 54 (04) :221-226
[35]   THE IMPACT OF RESEARCH ON SCALING AND ROOT PLANING [J].
OLEARY, TJ .
JOURNAL OF PERIODONTOLOGY, 1986, 57 (02) :69-75
[36]   SURFACE CHARACTERISTICS OF TEETH FOLLOWING PERIODONTAL INSTRUMENTATION - SCANNING ELECTRON-MICROSCOPE STUDY [J].
PAMEIJER, CH ;
STALLARD, RE ;
HIEP, N .
JOURNAL OF PERIODONTOLOGY, 1972, 43 (10) :628-&
[37]  
RIFFLE AB, 1952, J PERIODONTOL, V23, P170
[38]   AN INVITRO INVESTIGATION ON THE LOSS OF ROOT SUBSTANCE IN SCALING WITH VARIOUS INSTRUMENTS [J].
RITZ, L ;
HEFTI, AF ;
RATEITSCHAK, KH .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1991, 18 (09) :643-647
[39]   EFFECT OF ROOT ROUGHNESS ON PLAQUE ACCUMULATION AND GINGIVAL INFLAMMATION [J].
ROSENBERG, RM ;
ASH, MM .
JOURNAL OF PERIODONTOLOGY, 1974, 45 (03) :146-150
[40]   ANALYSIS OF ROOT SURFACE CHANGES IN PERIODONTAL-DISEASE - REVIEW [J].
RUBEN, MP ;
SHAPIRO, A .
JOURNAL OF PERIODONTOLOGY, 1978, 49 (02) :89-91