Selective detection of biogenic amines using capillary electrochromatography with an on-column derivatization technique

被引:50
作者
Oguri, S
Yoneya, Y
Mizunuma, M
Fujiki, Y
Otsuka, K
Terabe, S
机构
[1] Aichi Gakusen Univ, Dept Home Econ, Okazaki, Aichi 4448520, Japan
[2] Himeji Inst Technol, Fac Sci, Ako, Hyogo 678129, Japan
关键词
D O I
10.1021/ac025592d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A selective detection method for biogenic amines present in highly complex matrixes was devised by employing both electrokinetic injection and on-column-derivatization capillary electrochromatographic methods. The on-column derivatization capillary electrochromatography system was evaluated by use of a capillary column (total length of 45 cm, effective length of 25 cm) fabricated using a 100-mum (i.d.) fused-silica capillary tube packed with 5-mum (i.d.) ODS particles that were tolerant of an alkaline environment. The column was filled with a run buffer consisting of a derivatization reagent, o-phthalaldehyde/2-mercaptoethanol, in a mixture of borate buffer (pH 10). After electrokinetic injection of a mixture of five biogenic amines (histamine, serotonin, tyramine, putrescine, cadaverine) as a test sample, the free amines entered into the anodic site of the capillary column and started to travel along the column, during which time the analytes reacted with the derivatization reagent, separated out, and were detected with an absorbance at 340 nm when high voltage was applied to the column. When this system was applied to a mixture containing 5 biogenic amines and 17 amino acids, the 5 biogenic amines plus arginine selectively entered into the capillary with the electrokinetic injection and were observed on the electrochromatogram, but none of the amino acids lacking arginine were detected. The designated method was also tested for its ability to determine the presence of biogenic amines in the crude extracts obtained from two types of aged fish.
引用
收藏
页码:3463 / 3469
页数:7
相关论文
共 32 条
[21]  
PORTER CW, 1987, CANCER, V60, P1275, DOI 10.1002/1097-0142(19870915)60:6<1275::AID-CNCR2820600619>3.0.CO
[22]  
2-I
[23]  
RUSSELL DH, 1977, CLIN CHEM, V23, P22
[24]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF HISTAMINE AND 1-METHYLHISTAMINE WITH ON-COLUMN FLUORESCENCE DERIVATIZATION [J].
SAITO, K ;
HORIE, M ;
NOSE, N ;
NAKAGOMI, K ;
NAKAZAWA, H .
JOURNAL OF CHROMATOGRAPHY, 1992, 595 (1-2) :163-168
[25]  
Seiler N, 1970, Methods Biochem Anal, V18, P259, DOI 10.1002/9780470110362.ch5
[26]   THE PHYSIOLOGY AND BIOCHEMISTRY OF POLYAMINES IN PLANTS [J].
SLOCUM, RD ;
KAURSAWHNEY, R ;
GALSTON, AW .
ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 1984, 235 (02) :283-303
[27]  
SORENSON H, 1999, CHROMATOGRAPHY CAPIL
[28]   Instrumentation for capillary electrochromatography [J].
Steiner, F ;
Scherer, B .
JOURNAL OF CHROMATOGRAPHY A, 2000, 887 (1-2) :55-83
[29]  
TAKAMI H, 1979, LANCET, V2, P912
[30]  
UEHARA N, 1980, CANCER, V45, P108, DOI 10.1002/1097-0142(19800101)45:1<108::AID-CNCR2820450120>3.0.CO