Microfabricated centrifugal microfluidic systems: Characterization and multiple enzymatic assays

被引:404
作者
Duffy, DC [1 ]
Gillis, HL [1 ]
Lin, J [1 ]
Sheppard, NF [1 ]
Kellogg, GJ [1 ]
机构
[1] Gamera Biosci, Medford, MA 02115 USA
关键词
D O I
10.1021/ac990682c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes a microfluidic system in which fluids are pumped by centrifugal force through microscopic channels defined in a plastic disk in order to perform complex analytical processes. The channels are created either by casting poly(dimethylsiloxane) against molds fabricated by photolithography or by conventional machining of poly(methyl methyacrylate). The channels have a wide range of diameters (5 mu m-0.5 mm) and depths (16 mu m-3 mm), Fluids are loaded into reservoirs near the center of the disk, the disk is rotated on the shaft of a simple motor at 60-3000 rpm, and the fluids are pumped outward by centrifugal force through microfluidic networks. The control of now in the time domain, i.e., gating, is achieved by the use of passive valves based on capillary forces. Flow rates ranging from 5 nL/s to >0.1 mL/s have been achieved using channels of different dimensions and different rates of rotation. The method of pumping is insensitive to many physicochemical properties of the liquid, such as pH and ionic strength, so it has been possible to pump biological fluids, such as blood and urine, a buffer containing a detergent, and some organic solvents. A system that performs multiple (48) enzymatic assays simultaneously using colorimetric detection on a dedicated instrument has been demonstrated. These integrated assays have been used both to yield the Michaelis constant (K-m) of an enzyme and to determine the dose response of an enzyme to a drug. The fluid pumping and:control embodied in this system may be readily integrated with other analytical components (e.g., heating, detection, and informatics) to form the basis for a microscale total analysis system for use in genomics, proteomics; high-throughput screening, and molecular diagnostics.
引用
收藏
页码:4669 / 4678
页数:10
相关论文
共 37 条
[1]  
Adamson A. W., 1997, PHYS CHEM SURFACES
[2]   Detection system for reaction-rate analysis in a low-volume proteinase-inhibition assay [J].
Ambrose, WP ;
Semin, DJ ;
Robbins, DL ;
Van Orden, A ;
Kashem, MA ;
Hamilton, SA ;
Nelson, RM ;
Jett, JH ;
Keller, RA .
ANALYTICAL BIOCHEMISTRY, 1998, 263 (02) :150-157
[3]   Microchip-based capillary electrophoresis for immunoassays: Analysis of monoclonal antibodies and theophylline [J].
Chiem, N ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1997, 69 (03) :373-378
[4]  
CHIEN S, 1984, HDB PHYSSL
[5]   Rapid prototyping of microfluidic systems in poly(dimethylsiloxane) [J].
Duffy, DC ;
McDonald, JC ;
Schueller, OJA ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :4974-4984
[6]  
DUFFY DC, 1999, UNPUB
[7]   Integrated chip-based capillary electrophoresis [J].
Effenhauser, CS ;
Bruin, GJM ;
Paulus, A .
ELECTROPHORESIS, 1997, 18 (12-13) :2203-2213
[8]  
Foulds N. C., 1990, BIOSENSORS PRACTICAL, P97
[9]   RAPID ELECTROCHEMICAL ASSAY FOR THEOPHYLLINE IN WHOLE-BLOOD BASED ON THE INHIBITION OF BOVINE LIVER ALKALINE-PHOSPHATASE [J].
FOULDS, NC ;
WILSHERE, JM ;
GREEN, MJ .
ANALYTICA CHIMICA ACTA, 1990, 229 (01) :57-62
[10]  
Fung Y.-C., 1993, Biomechanics: Mechanical Properties of Living Tissues, P66, DOI [10.1007/978-1-4757-2257-4_3, DOI 10.1007/978-1-4757-2257-4_3]