Numerical analysis of the inner flow field of a biocentrifugal blood pump

被引:17
作者
Chua, LP [1 ]
Song, GL [1 ]
Lim, TM [1 ]
Zhou, TM [1 ]
机构
[1] Nanyang Technol Univ, Sch Mech & Prod Engn, Singapore 639798, Singapore
关键词
inner flow; centrifugal blood pump; simulation; shear stress;
D O I
10.1111/j.1525-1594.2006.00243.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Implantable ventricular assist devices have been regarded as a promising instrument in the clinical treatment of patients with severe heart failures. In this article, a three-dimensional model of the Kyoto-NTN magnetically suspended centrifugal blood pump was generated and a computational fluid dynamics solution of the inner flow field of the pump including the static pressure distributions, velocity profiles, and the shear stress distributions of the blood was presented. The results revealed that reverse flow generally occurred in the impeller blade channels during the operation of the pump, due to the imbalance of the flow and the pressure gradient generated in the blade channels. The flow pattern at the exit of the blade channels was varying with its angular positions in the pump. The reverse flow at the exit of the impeller blade channels was found to be closely related with the static pressure distribution in the volute passage. Higher pressure in the volute caused severe backflow from the volute into the blade channels. To clarify the effects of a moving impeller on the blood, shear stresses of the blood in the pump were investigated according to the simulation results. The studies indicated that at the beginning of the splitter plate and the cutwater, the highest shear stress exceeded 700 Pa. At other regions such as the inlet and outlet of the impeller blade channels and some regions in the volute passage, shear stresses were found to be about 200 Pa. These areas are believed to have a high possibility of rendering blood trauma.
引用
收藏
页码:467 / 477
页数:11
相关论文
共 14 条
[1]   CENTRIFUGAL BLOOD PUMP WITH A MAGNETICALLY SUSPENDED IMPELLER [J].
AKAMATSU, T ;
NAKAZEKI, T ;
ITOH, H .
ARTIFICIAL ORGANS, 1992, 16 (03) :305-308
[2]  
AKAMATSU T, 1994, P 3 JSME KSME FLUIDS, P305
[3]   Computational flow study of the continuous flow ventricular assist device, prototype number 3 blood pump [J].
Anderson, JB ;
Wood, HG ;
Allaire, PE ;
Bearnson, G ;
Khanwilkar, P .
ARTIFICIAL ORGANS, 2000, 24 (05) :377-385
[4]  
Andrews J, 2000, ARTIF ORGANS, V24, P492
[5]   MODEL FOR A GENERAL MECHANICAL BLOOD DAMAGE PREDICTION [J].
BLUDSZUWEIT, C .
ARTIFICIAL ORGANS, 1995, 19 (07) :583-589
[6]   Measurements of gap pressure and wall shear stress of a blood pump model [J].
Chua, LP ;
Akamatsu, T .
MEDICAL ENGINEERING & PHYSICS, 2000, 22 (03) :175-188
[7]   Computational fluid dynamics of gap flow in a biocentrifugal blood pump [J].
Chua, LP ;
Song, GL ;
Yu, SCM ;
Lim, TM .
ARTIFICIAL ORGANS, 2005, 29 (08) :620-628
[8]   Leakage flow rate and wall shear stress distributions in a biocentrifugal ventricular assist device [J].
Chua, LP ;
Ong, KS ;
Yu, CMS ;
Zhou, TM .
ASAIO JOURNAL, 2004, 50 (06) :530-536
[9]   Leakage flow measurements in a bio-centrifugal ventricular assist device model [J].
Chua, LP ;
Ong, KS ;
Yu, CMS ;
Zhou, TM .
ARTIFICIAL ORGANS, 2003, 27 (10) :942-959
[10]   Medical progress - Implantable left ventricular assist devices [J].
Goldstein, DJ ;
Oz, MC ;
Rose, EA .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (21) :1522-1533