Highly Sensitive Amperometric Cholesterol Biosensor Based on Pt-Incorporated Fullerene-like ZnO Nanospheres

被引:132
作者
Ahmad, Mashkoor [1 ]
Pan, Caofeng [1 ]
Gan, Lin [1 ]
Nawaz, Zeeshan [2 ]
Zhu, Jing [1 ]
机构
[1] Tsinghua Univ, Dept Mat Sci & Engn, Lab Adv Mat,Beijing Natl Ctr Electron Microscopy, State Key Lab New Ceram & Fine Proc, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Dept Chem Engn, Beijing Key Lab Green Chem React Engn & Technol, Beijing 100084, Peoples R China
关键词
HYDROGEN-PEROXIDE; OXIDASE; FILMS; SERUM; NANOPARTICLES;
D O I
10.1021/jp9089497
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A highly sensitive amperometric biosensor based on Pt-incorporated fullerene-like ZnO hybrid nanospheres has been investigated. Pt-ZnO nanospheres (PtZONS) with diameters in the range 50-200 nm have been successfully synthesized by electrodeposition on a glassy carbon electrode (GCE). The Pt nanoparticles in ZnO nanospheres have been identified with high-resolution transmission electron microscopy (HRTEM) and energy dispersive X-ray spectroscopy (EDS). The doped Pt nanoparticles demonstrate the abilities to electrocatalyze the oxidation of hydrogen peroxide and substantially raise the response current. The sensitivity of the PtZONS/GCE to hydrogen peroxide is 147.8 mu A mu M-1 cm(-2), which is much higher than that of a conventional electrode. The PtZONS/GCE was functionalized with cholesterol oxidase (ChOx) by physical adsorption. The enzyme electrode exhibits a very high and reproducible sensitivity of 1886.4 mA M-1 cm(-2) to cholesterol with a response time less than 5 s and a linear range from 0.5 to 15 mu M. Furthermore, it has been revealed that the biosensor exhibits a good anti-interference ability and favorable stability over relatively long-term storage (more than 5 weeks). All these results strongly suggest that the PtZONS not only enhance the sensitivity to cholesterol but also help to eliminate the interference at low applied potential.
引用
收藏
页码:243 / 250
页数:8
相关论文
共 37 条
[1]   Metal-dispersed conducting polymer-coated electrode used for oxidase-based biosensors [J].
Arjsiriwat, S ;
Tanticharoen, M ;
Kirtikara, K ;
Aoki, K ;
Somasundrum, M .
ELECTROCHEMISTRY COMMUNICATIONS, 2000, 2 (06) :441-444
[2]   Electrocatalytic properties of platinum particles incorporated with polypyrrole films in D-glucose oxidation in phosphate media [J].
Becerik, I ;
Kadirgan, F .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1997, 436 (1-2) :189-193
[3]   Amperometric determination of cholesterol in serum using a biosensor of cholesterol oxidase contained within a polypyrrole-hydrogel membrane [J].
Brahim, S ;
Narinesingh, D ;
Guiseppi-Elie, A .
ANALYTICA CHIMICA ACTA, 2001, 448 (1-2) :27-36
[4]  
CHIA YL, 2009, AIP C P, V1137, P123
[5]  
CHRISTINA B, 2004, J AM CHEM SOC, V126, P8028
[6]  
Coleman VA, 2006, ZINC OXIDE BULK, THIN FILMS AND NANOSTRUCTURES: PROCESSING, PROPERTIES AND APPLICATIONS, P1, DOI 10.1016/B978-008044722-3/50001-4
[7]   Gate-refreshable nanowire chemical sensors [J].
Fan, ZY ;
Lu, JG .
APPLIED PHYSICS LETTERS, 2005, 86 (12) :1-3
[8]  
Gregory J.E., 1998, J VAC SCI TECHNOL A, V16, P1926
[9]   Electrochemical oxidation of hydrogen peroxide at platinum electrodes. Part V: inhibition by chloride [J].
Hall, SB ;
Khudaish, EA ;
Hart, AL .
ELECTROCHIMICA ACTA, 2000, 45 (21) :3573-3579
[10]  
HENDJI AN, 1993, SENSOR ACTUAT B-CHEM, V15, P127, DOI 10.1016/0925-4005(93)85038-C