Amperometric determination of cholesterol in serum using a biosensor of cholesterol oxidase contained within a polypyrrole-hydrogel membrane

被引:158
作者
Brahim, S
Narinesingh, D
Guiseppi-Elie, A
机构
[1] Univ W Indies, Dept Chem, Fac Agr & Nat Sci, St Augustine, Trinidad Tobago
[2] Virginia Commonwealth Univ, Ctr Bioelect, Dept Chem Engn, Biosensors & Biochips C3B, Richmond, VA 23284 USA
关键词
cholesterol biosensor; cholesterol oxidase; amperometry; poly HEMA/polypyrrole membrane;
D O I
10.1016/S0003-2670(01)01321-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid, two-step method for constructing cholesterol biosensors. by entrapment of cholesterol oxidase (ChOx) within a composite poly(2-hydroxyethyl methacrylate)(p(HEMA))/polypyrrole (p(pyrrole)) membrane has been developed. Platinum electrode-supported polymer films were prepared by UV polymerization of the hydrogel component containing dissolved enzyme followed immediately by electrochemical polymerization of entrapped pyrrole monomer (Py) within the performed hydrogel network. The optimized cholesterol biosensor exhibited a linear response range from 5 x 10(-4) to 1.5 x 10(-2) M and detection limit of 120 muM toward cholesterol. The response time of the biosensor was 30 s. The analytical recovery of cholesterol in serum samples ranged from 97 to 103% with mean coefficients of variation of 3% (within-day analyses) and 3.9% (day-to-day analyses). Up to 60 samples/h can be manually analyzed. The cholesterol biosensor retained 80% of initial activity after 12 months when stored desiccated in the absence of buffer. When applied to the analysis of cholesterol in serum samples of clinical patients, >0.998 correlation was obtained between the biosensor results and those obtained by a standard hospital method using an Abbott V.P, Chemistry Analyzer. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:27 / 36
页数:10
相关论文
共 41 条
  • [1] THE APPLICATION OF CONDUCTING POLYMERS IN BIOSENSORS
    BARTLETT, PN
    BIRKIN, PR
    [J]. SYNTHETIC METALS, 1993, 61 (1-2) : 15 - 21
  • [2] BERGMEYER HU, 1988, METHOD ENZYMAT AN, P168
  • [3] Improvement of the analytical characteristics of an enzyme electrode for free and total cholesterol via laponite clay additives
    Besombes, JL
    Cosnier, S
    Labbe, P
    Reverdy, G
    [J]. ANALYTICA CHIMICA ACTA, 1995, 317 (1-3) : 275 - 280
  • [4] Improvement of poly(amphiphilic pyrrole) enzyme electrodes via the incorporation of synthetic laponite-clay-nanoparticles
    Besombes, JL
    Cosnier, S
    Labbe, P
    [J]. TALANTA, 1997, 44 (12) : 2209 - 2215
  • [5] BRAHIM S, IN PRESS ELECTROANAL
  • [6] BRAHIM S, IN PRESS BIOSENS BIO
  • [7] ENZYME CATALYSIS AT HYDROGEL-MODIFIED ELECTRODES WITH REDOX POLYMER MEDIATOR
    CALVO, EJ
    DANILOWICZ, C
    DIAZ, L
    [J]. JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1993, 89 (02): : 377 - 384
  • [8] FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE
    CASS, AEG
    DAVIS, G
    FRANCIS, GD
    HILL, HAO
    ASTON, WJ
    HIGGINS, IJ
    PLOTKIN, EV
    SCOTT, LDL
    TURNER, APF
    [J]. ANALYTICAL CHEMISTRY, 1984, 56 (04) : 667 - 671
  • [9] Amperometric determination of cholesterol in serum with use of a renewable surface peroxidase electrode
    Charpentier, L
    ElMurr, N
    [J]. ANALYTICA CHIMICA ACTA, 1995, 318 (01) : 89 - 93
  • [10] A CARRAGEENAN HYDROGEL STABILIZED COLLOIDAL GOLD MULTIENZYME BIOSENSOR ELECTRODE UTILIZING IMMOBILIZED HORSERADISH-PEROXIDASE AND CHOLESTEROL OXIDASE CHOLESTEROL ESTERASE TO DETECT CHOLESTEROL IN SERUM AND WHOLE-BLOOD
    CRUBLISS, AL
    STONEHUERNER, JG
    HENKENS, RW
    ZHAO, J
    ODALY, JP
    [J]. BIOSENSORS & BIOELECTRONICS, 1993, 8 (06) : 331 - 337