Range-energy relation, range straggling and response function of CsI(Tl), EGO and GSO(Ce) scintillators for light ions

被引:15
作者
Avdeichikov, V [1 ]
Fomichev, AS
Jakobsson, B
Rodin, AM
Ter-Akopian, GM
机构
[1] Lund Univ, Dept Phys, Box 118, S-22100 Lund, Sweden
[2] Joint Inst Nucl Res, Dubna 141980, Russia
关键词
inorganic scintillators; light ions; range and straggling;
D O I
10.1016/S0168-9002(99)00944-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Range-energy relations and range straggling of H-1,H-2,H-3 and He-4,He-6 isotopes with the energy approximate to 50A MeV are measured for the CsI(Tl), BGO and GSO(Ce) scintillators with an accuracy better than 0.2% and 5%, respectively. The Si-Sci/PD telescope was exposed to secondary beams from the mass separator ACCULINNA. The experimental technique is based on the registration of the "jump" in the amplitude of the photodiode signal for ions passing through the scintillation crystal. Light response of the scintillators for ions 1 less than or equal to Z less than or equal to 4 is measured in energy range (5-50)A MeV, the results are in good agreement with calculations based on Birks model. The energy loss straggling for particles with Delta E/E = 0.01-0.50 and mass up to A = 10 in 256 mu m Delta E silicon detector is studied and compared with theoretical prescriptions. The results allow a precise absolute calibration of the scintillation crystal and to optimize the particle identification by the Delta E-E(Sci/PD) method. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:158 / 166
页数:9
相关论文
共 17 条
[1]  
AIELLO S, 1995, NUCL PHYS A, V583, pC461
[2]  
*AMPH COLL, 1989, NUCL INSTRUM METH A, V281, P528
[3]  
Avdeichikov V, 1997, NUCL PHYS A, V626, p439C
[4]   A method for precise absolute calibration of scintillator/photodiode detectors [J].
Avdeichikov, VV ;
Jakobsson, B ;
van Veldhuizen, EJ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 418 (2-3) :522-525
[5]   CALIBRATION OF THE RESPONSE FUNCTION OF CSI(TL) SCINTILLATORS TO INTERMEDIATE-ENERGY HEAVY-IONS [J].
COLONNA, N ;
WOZNIAK, GJ ;
VEECK, A ;
SKULSKI, W ;
GOTH, GW ;
MANDUCI, L ;
MILAZZO, PM ;
MASTINU, PF .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 321 (03) :529-534
[6]   THE RESPONSE OF A LARGE CSI(TL) DETECTOR TO LIGHT PARTICLES AND HEAVY-IONS IN THE INTERMEDIATE-ENERGY RANGE [J].
FOMICHEV, AS ;
DAVID, I ;
LUKYANOV, SM ;
PENIONZHKEVICH, YE ;
SKOBELEV, NK ;
TARASOV, OB ;
MATTHIES, A ;
ORTLEPP, HG ;
WAGNER, W ;
LEWITOWICZ, M ;
STLAURENT, MG ;
CORRE, JM ;
DLOUHY, Z ;
PECINA, I ;
BORCEA, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 344 (02) :378-383
[7]   THE MASS DEPENDENCE OF CSI(TL) SCINTILLATION RESPONSE TO HEAVY-IONS [J].
HORN, D ;
BALL, GC ;
GALINDOURIBARRI, A ;
HAGBERG, E ;
WALKER, RB ;
LAFOREST, R ;
POULIOT, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 320 (1-2) :273-276
[8]  
Hubert F., 1980, ANN PHYS PARIS S, V5, P1
[9]   CALIBRATION OF CSI(TL) SCINTILLATORS FOR HEAVY-IONS (3-LESS-THAN-OR-EQUAL-TO-Z-LESS-THAN-OR-EQUAL-TO-54) IN A WIDE ENERGY-RANGE (E/U-LESS-THAN-OR-EQUAL-TO-60 ME V/U) [J].
MASTINU, PF ;
MILAZZO, PM ;
BRUNO, M ;
DAGOSTINO, M ;
MANDUCI, L .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 338 (2-3) :419-424
[10]   SCINTILLATION RESPONSE OF ACTIVATED INORGANIC CRYSTALS TO VARIOUS CHARGED PARTICLES [J].
MURRAY, RB ;
MEYER, A .
PHYSICAL REVIEW, 1961, 122 (03) :815-&