Biomechanical evaluation of a new augmentation method for enhanced screw fixation in osteoporotic proximal femoral fractures

被引:60
作者
von der Linden, P.
Gisep, A. [1 ]
Boner, V.
Windolf, M.
Appelt, A.
Suhm, N.
机构
[1] AO Dev Inst, Davos, Switzerland
[2] AO Res Inst, Davos, Switzerland
[3] Heidelberg Univ, Dept Traumatol, Heidelberg, Germany
关键词
osteoporosis; cement augmentation; high pressure irrigation; hip fracture; cut-out;
D O I
10.1002/jor.20299
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A biomechanical investigation on eight pairs of human cadaver proximal femurs was performed to evaluate the impact of a new augmentation method on the internal fixation of osteoporotic proximal femur fractures. The study focused on enhancing implant purchase to reduce the incidence of implant cut-out in osteoporotic bone. In a left-right comparison, a conventional hip screw fixation (control) was compared to the new cement augmentation method. After bone bed preparation through high pressure irrigation to remove fat, blood, and bone debris, the bones were augmented with low viscosity polymethylmethacrylate (PMMA) cement. Step-wise fatigue testing was performed by cyclically loading the femoral heads in a physiological manner, beginning at 1,500 N and increasing 500 N every 5,000 cycles to 4,000 N, and continuously monitoring head displacement. Failure was defined as > 5.0 mm head displacement. The head displacement at 2,000 N was significantly smaller (p = 0.018) for the augmented group as compared to the conventionally treated bones (0.09 +/- 0.01 mm vs. 0.90 +/- 0.32 mm; mean +/- SEM). The displacement rate at the second load step was significantly higher (p = 0.018) for the conventionally treated bones as compared to the augmented ones. All of the nonaugmented specimens failed during testing, where 50% of the augmented specimens did not fail. The promising results of these experiments suggest that this new standardized irrigation/augmentation method enhances the implant anchorage and offers a potential solution to the problem of implant cut-out in osteoporotic metaphyseal bone. (c) 2006 Orthopaedic Research Society.
引用
收藏
页码:2230 / 2237
页数:8
相关论文
共 43 条
[1]
A modified hip screw incorporating injected cement for the fixation of osteoporotic trochanteric fractures [J].
Augat, P ;
Rapp, S ;
Claes, L .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2002, 16 (05) :311-316
[2]
Baroud G, 2004, BIO-MED MATER ENG, V14, P487
[3]
THE EFFECT OF ADJUNCTIVE METHYLMETHACRYLATE ON FAILURES OF FIXATION AND FUNCTION IN PATIENTS WITH INTERTROCHANTERIC FRACTURES AND OSTEOPOROSIS [J].
BARTUCCI, EJ ;
GONZALEZ, MH ;
COOPERMAN, DR ;
FREEDBERG, HI ;
BARMADA, R ;
LAROS, GS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (07) :1094-1107
[4]
THE VALUE OF THE TIP-APEX DISTANCE IN PREDICTING FAILURE OF FIXATION OF PERITROCHANTERIC FRACTURES OF THE HIP [J].
BAUMGAERTNER, MR ;
CURTIN, SL ;
LINDSKOG, DM ;
KEGGI, JM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (07) :1058-1064
[5]
Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip [J].
Baumgaertner, MR ;
Solberg, BD .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (06) :969-971
[6]
HIP-JOINT LOADING DURING WALKING AND RUNNING, MEASURED IN 2 PATIENTS [J].
BERGMANN, G ;
GRAICHEN, F ;
ROHLMANN, A .
JOURNAL OF BIOMECHANICS, 1993, 26 (08) :969-990
[7]
Hip contact forces and gait patterns from routine activities [J].
Bergmann, G ;
Deuretzbacher, G ;
Heller, M ;
Graichen, F ;
Rohlmann, A ;
Strauss, J ;
Duda, GN .
JOURNAL OF BIOMECHANICS, 2001, 34 (07) :859-871
[8]
Lavage technique in total hip arthroplasty - Jet lavage produces better cement penetration than syringe lavage in the proximal femur [J].
Breusch, SJ ;
Norman, TL ;
Schneider, U ;
Reitzel, T ;
Blaha, JD ;
Lukoschek, M .
JOURNAL OF ARTHROPLASTY, 2000, 15 (07) :921-927
[9]
Breusch SJ, 2000, ORTHOPADE, V29, P260
[10]
The significance of pulsatile lavage for improved in vitro and in vivo cement penetration. [J].
Breusch, SJ ;
Schneider, U ;
Reitzel, T ;
Kreutzer, J ;
Ewerbeck, V ;
Lukoschek, M .
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2001, 139 (01) :52-63