Automated at-line solid-phase extraction gas chromatographic analysis of micropollutants in water using the PrepStation

被引:15
作者
Hankemeier, T
Steketee, PC
Vreuls, JJ
Brinkman, UAT
机构
关键词
water analysis; sample preparation; automation; environmental analysis; pestide; pesticides; triazines; organophosphorus compounds; large volume injection;
D O I
10.1016/0021-9673(96)00556-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A fully automated at-line solid-phase extraction-gas chromatography procedure has been developed for the analysis of aqueous samples using the PrepStation. The sample extract is transferred from the sample preparation module to the gas chromatograph via an autosampler vial. With flame-ionization detection, limits of determination (S/N=10) of 0.05-0.13 mu g/l were obtained for the analysis of HPLC-grade water when modifying the PrepStation by: (i) increasing the sample volume to 50 ml, (ii) increasing the injection volume up to 50 mu l, and (iii) decreasing the desorption volume to 300 mu l. The HP autosampler had to be modified to enable the automated ''at-once'' on-column injection of up to 50 mu l of sample extract. The amount of packing material in the original cartridge had to be reduced to effect The decrease of the desorption volume. The total set-up did not require any further optimization after having set up the method once. The analytical characteristics of the organonitrogen and organophosphorus test analytes, i.e. recoveries (typically 75-105%), repeatability (2-8%) and linearity (0.09-3.0 mu g/l) were satisfactory. The potential of the system was demonstrated by determining triazines and organophosphorus pesticides in river Rhine water at the 0.6 mu g/l level using flame-ionization and mass-selective detection. No practical problems were observed during the analysis of more than 100 river water samples.
引用
收藏
页码:161 / 174
页数:14
相关论文
共 16 条
[1]   EMPIRICAL PREDICTION OF ORGANIC POLLUTANT SORPTION IN NATURAL SEDIMENTS [J].
BROWN, DS ;
FLAGG, EW .
JOURNAL OF ENVIRONMENTAL QUALITY, 1981, 10 (03) :382-386
[2]  
Fogelman K. D., 1993, Laboratory Robotics and Automation, V5, P103
[3]   ON-COLUMN INJECTION OF LARGE SAMPLE VOLUMES USING THE RETENTION GAP TECHNIQUE IN CAPILLARY GAS-CHROMATOGRAPHY [J].
GROB, K ;
KARRER, G ;
RIEKKOLA, ML .
JOURNAL OF CHROMATOGRAPHY, 1985, 334 (02) :129-155
[4]   MOVEMENTS OF THE SAMPLE PLUG IN THE COLUMN INLET AFTER ON-COLUMN INJECTION IN CAPILLARY GAS-CHROMATOGRAPHY [J].
GROB, K .
JOURNAL OF CHROMATOGRAPHY, 1984, 283 (JAN) :21-35
[5]  
GROB K, 1987, COLUMN INJECTION CAP
[6]  
GROB K, 1991, ONLINE COUPLED LG GC, P209
[7]   ONLINE COUPLING OF SOLID-PHASE EXTRACTION AND GAS-CHROMATOGRAPHY WITH ATOMIC-EMISSION DETECTION FOR ANALYSIS OF TRACE POLLUTANTS IN AQUEOUS SAMPLES [J].
HANKEMEIER, T ;
LOUTER, AJH ;
RINKEMA, FD ;
BRINKMAN, UAT .
CHROMATOGRAPHIA, 1995, 40 (3-4) :119-124
[8]   ONLINE VERSUS OFF-LINE SOLID-PHASE EXTRACTION IN THE DETERMINATION OF ORGANIC CONTAMINANTS IN WATER - ADVANTAGES AND LIMITATIONS [J].
LISKA, I .
JOURNAL OF CHROMATOGRAPHY A, 1993, 655 (02) :163-176
[9]   Analysis of microcontaminants in aqueous samples by fully automated on-line solid-phase extraction gas chromatography mass selective detection [J].
Louter, AJH ;
vanBeekvelt, CA ;
Montanes, PC ;
Slobodnik, J ;
Vreuls, JJ ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 1996, 725 (01) :67-83
[10]  
LOUTER AJH, 1993, J MICROCOLUMN SEP, V5, P3031