Venovenous extracorporeal membrane oxygenation: The effects of proximal internal jugular cannulation

被引:14
作者
Finer, NN
Tierney, AJ
Ainsworth, W
机构
[1] UNIV ALBERTA,EDMONTON,AB,CANADA
[2] ROYAL ALEXANDRA HOSP CHILDREN,DEPT NEWBORN MED,CAMPERDOWN,NSW,AUSTRALIA
关键词
extracorporeal membrane oxygenation; venovenous; venoarterial;
D O I
10.1016/S0022-3468(96)90836-2
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Venovenous (VV) extracorporeal membrane oxygenation (ECMO) using a double-lumen catheter has become an accepted method of providing ECMO support for critically ill newborn infants. In addition, use of the cephalic jugular catheter can provide augmented venous blood Row, potentially prevent increased cerebral venous pressure, maintain cerebral venous blood flow, and increase ECMO oxygen delivery. The authors compared their experience using VV double-lumen (VVDL) ECMO with a cephalic jugular catheter with their previous experience using venoarterial (VA) ECMO. They compared 15 infants who had meconium aspiration syndrome (MAS) and 12 who had congenital diaphragmatic hernia (CDH) treated with VVDL ECMO with a cephalic jugular catheter with the same number of infants with each condition treated with VA ECMO (historical controls). There were no significant differences between the groups with respect to birth weights, oxygen indexes before ECMO, or ECMO flows at 4 and 24 hours. For infants with MAS treated with VVDL ECMO, the overall duration of ECMO support was significantly shorter (63 hours VVDL v 118 hours VA; P = .001), and the average cephalic flow was 33 mL/kg for infants treated with VVDL support. For infants with CDH, there were no differences in any of the variables evaluated, including total duration (100 hours VVDL v 128 hours VA; P = .06 [NS]), and the average cephalic flow was 39 mL/kg for infants treated with VVDL support. The venous oxygen content was significantly lower in infants with MAS treated with VVDL ECMO than for historical controls treated with VA ECMO at 4 hours of ECMO support (15.8 v 16.7; P less than or equal to .05). No other significant differences were noted for any of the calculated oxygen transport variables comparing VVDL with VA ECMO. Infants with CDH treated with VVDL ECMO were extubated sooner than those treated with VA ECMO (10.3 days VVDL v 15.4 days VA; P = .048). In addition, there was no significant difference in the overall incidence of complications or death. This experience suggests that VVDL ECMO using a cephalic jugular catheter results in shorter ECMO runs and provides support that is comparable to VA ECMO for infants with CDH and MAS while avoiding carotid artery cannulation and ligation. Copyright (C) 1996 by W.B. Saunders Company
引用
收藏
页码:1391 / 1395
页数:5
相关论文
共 15 条
[11]   THE CEREBROVASCULAR RESPONSE TO PROLONGED HYPOXIA WITH CAROTID-ARTERY AND JUGULAR-VEIN LIGATION IN THE NEWBORN LAMB [J].
SHORT, BL ;
BENDER, K ;
WALKER, LK ;
TRAYSTMAN, RJ .
JOURNAL OF PEDIATRIC SURGERY, 1994, 29 (07) :887-891
[12]   INTRACRANIAL VENOUS SYSTEM IN NEWBORNS TREATED WITH EXTRACORPOREAL MEMBRANE-OXYGENATION - DOPPLER US EVALUATION AFTER LIGATION OF THE RIGHT JUGULAR-VEIN [J].
TAYLOR, GA ;
WALKER, LK .
RADIOLOGY, 1992, 183 (02) :453-456
[13]  
TAYLOR GA, 1992, 8 ANN CHILDR NAT MED
[14]  
VANMEURS KP, 1995, J PEDIATR, V125, P304
[15]  
Zwischenberger J B, 1985, Trans Am Soc Artif Intern Organs, V31, P610