Respiration correlated cone-beam computed tomography and 4DCT for evaluating target motion in Stereotactic Lung Radiation Therapy

被引:100
作者
Purdie, Thomas G.
Moseley, Douglas J.
Bissonnette, Jean-Pierre
Sharpe, Michael B.
Franks, Kevin
Bezjak, Andrea
Jaffray, David A.
机构
[1] Princess Margaret Hosp, Dept Radiat Phys, Ontario Canc Inst, Toronto, ON M5G 2M9, Canada
[2] Univ Toronto, Dept Radiat Oncol, Toronto, ON M5G 2M9, Canada
关键词
D O I
10.1080/02841860600907345
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
An image-guidance process for using cone-beam computed tomography (CBCT) for stereotactic body radiation therapy (SBRT) of peripheral lung lesions is presented. Respiration correlated CBCT on the treatment unit and four dimensional computed tomography (4DCT) from planning are evaluated for assessing respiration-induced target motion during planning and treatment fractions. Image-guided SBRT was performed for 12 patients (13 lesions) with inoperable early stage non-small cell lung carcinoma. Kilovoltage (kV) projections were acquired over a 360 degree gantry rotation and sorted based on the pixel value of an image-based aperture located at the air-tissue interface of the diaphragm. The sorted projections were reconstructed to provide volumetric respiration correlated CBCT image datasets at different phases of the respiratory cycle. The 4D volumetric datasets were directly compared with 4DCT datasets acquired at the time of planning. For ten of 12 patients treated, the lung tumour motion, as measured by respiration correlated CBCT on the treatment unit, was consistent with the tumour motion measured by 4DCT at the time of planning. However, in two patients, maximum discrepancies observed were 6 and 10 mm in the anterior-posterior and superior-inferior directions, respectively. Respiration correlated CBCT acquired on the treatment unit allows target motion to be assessed for each treatment fraction, allows target localization based on different phases on the breathing cycle, and provides the facility for adaptive margin design in radiation therapy of lung malignancies. The current study has shown that the relative motion and position of the tumour at the time of treatment may not match that of the planning 4DCT scan. Therefore, application of breathing motion data acquired at simulation for tracking or gating radiation therapy may not be suitable for all patients - even those receiving short course treatment techniques such as SBRT.
引用
收藏
页码:915 / 922
页数:8
相关论文
共 24 条
[1]  
Blomgren H, 1998, Journal of Radiosurgery, V1, P63
[2]  
Hof H, 2003, STRAHLENTHER ONKOL, V179, P542, DOI 10.1007/s00066-003-1070-8
[3]   Stereotactic single-dose radiotherapy of Stage I non-small-cell lung cancer (NSCLC) [J].
Hof, H ;
Herfarth, KK ;
Münter, M ;
Hoess, A ;
Motsch, J ;
Wannenmacher, M ;
Debus, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (02) :335-341
[4]   Correlation of lung tumor motion with external surrogate indicators of respiration [J].
Hoisak, JDP ;
Sixel, KE ;
Tirona, R ;
Cheung, PCF ;
Pignol, JP .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (04) :1298-1306
[5]  
*ICRU INT COMM RAD, 1999, 62 ICRU INT COMM RAD
[6]   Flat-panel cone-beam computed tomography for image-guided radiation therapy [J].
Jaffray, DA ;
Siewerdsen, JH ;
Wong, JW ;
Martinez, AA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05) :1337-1349
[7]   A new irradiation unit constructed of self-moving gantry-CT and linac [J].
Kuriyama, K ;
Onishi, H ;
Sano, N ;
Komiyama, T ;
Aikawa, Y ;
Tateda, Y ;
Araki, T ;
Uematsu, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 55 (02) :428-435
[8]  
Lax I., 1998, J Radiosurgery, V1, P135, DOI [DOI 10.1023/B:JORA.0000010898.87146.2E, 10.1023/B:JORA.0000010898.87146.e, DOI 10.1023/B:JORA.0000010898.87146.E, 10.1023/B:JORA.0000010898.87146.2e]
[9]   Measurement of lung tumor motion using respiration-correlated CT [J].
Mageras, GS ;
Pevsner, A ;
Yorke, ED ;
Rosenzweig, KE ;
Ford, EC ;
Hertanto, A ;
Larson, SM ;
Lovelock, DM ;
Erdi, YE ;
Nehmeh, SA ;
Humm, JL ;
Ling, CC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (03) :933-941
[10]  
Moseley DJ, 2004, MED PHYS, V31, P1778