Color transcranial ''power'' Doppler ultrasound of intracranial aneurysms

被引:52
作者
Wardlaw, JM
Cannon, JC
机构
[1] Department of Clinical Neurosciences, Western General Hospital, Edinburgh
[2] Department of Clinical Neurosciences, Western General Hospital, Edinburgh EH4 2XU, Crewe Road
关键词
subarachnoid hemorrhage; aneurysm; transcranial Doppler ultrasound;
D O I
10.3171/jns.1996.84.3.0459
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
''Color Doppler energy'' (or ''power Doppler''), a new color Doppler ultrasound technique that is independent of flow direction and very sensitive to movement, was assessed for its use in the identification of intracranial aneurysms in patients with recent subarachnoid hemorrhage immediately prior to using cerebral angiography. Features that identified aneurysms using this technique included the appearance of abnormal color where no normal artery was expected, abnormal bulging of an artery, and greater ''expansibility'' of the aneurysm in comparison to an adjacent normal vessel. in this exploratory study, 30 of 33 aneurysms were correctly identified in 35 patients with a good bone window. Color Doppler energy is considerably more sensitive to intracranial blood flow than conventional color Doppler imaging. Color Doppler energy is a useful research tool; if these preliminary results are verified in larger series, in addition to examination for vasospasm, the technique could be used for identification and follow up of aneurysms.
引用
收藏
页码:459 / 461
页数:3
相关论文
共 9 条
[1]   TRANSCRANIAL COLOR-CODED REAL-TIME SONOGRAPHY IN THE EVALUATION OF INTRACRANIAL NEOPLASMS AND ARTERIOVENOUS-MALFORMATIONS [J].
BECKER, G ;
PEREZ, J ;
KRONE, A ;
DEMUTH, K ;
LINDNER, A ;
HOFMANN, E ;
WINKLER, J ;
BOGDAHN, U ;
SMITH, RR .
NEUROSURGERY, 1992, 31 (03) :420-428
[2]   DIAGNOSIS AND MONITORING OF SUBARACHNOID HEMORRHAGE BY TRANSCRANIAL COLOR-CODED REAL-TIME SONOGRAPHY [J].
BECKER, G ;
GREINER, K ;
KAUNE, B ;
WINKLER, J ;
BRAWANSKI, A ;
WARMUTHMETZ, M ;
BOGDAHN, U .
NEUROSURGERY, 1991, 28 (06) :814-820
[3]  
Becker G, 1993, TRANSCRANIAL DOPPLER, P51
[4]   MEASUREMENT OF BLOOD PERFUSION IN TISSUE USING DOPPLER ULTRASOUND [J].
DYMLING, SO ;
PERSSON, HW ;
HERTZ, CH .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (05) :433-444
[5]   TRANSCRANIAL COLOR-CODED SONOGRAPHY OF THE BASAL CEREBRAL-CIRCULATION - REFERENCE DATA FROM 115 VOLUNTEERS [J].
MARTIN, PJ ;
EVANS, DH ;
NAYLOR, AR .
STROKE, 1994, 25 (02) :390-396
[6]   PULSATILE INCREASES IN ANEURYSM SIZE DETERMINED BY CINE PHASE-CONTRAST MR-ANGIOGRAPHY [J].
MEYER, FB ;
HUSTON, J ;
RIEDERER, SS .
JOURNAL OF NEUROSURGERY, 1993, 78 (06) :879-883
[7]   A UNIFIED APPROACH TO MODELING THE BACKSCATTERED DOPPLER ULTRASOUND FROM BLOOD [J].
MO, LYL ;
COBBOLD, RSC .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (05) :450-461
[8]   TRANSCRANIAL COLOR-CODED DUPLEX SONOGRAPHY OF INTRACEREBRAL HEMATOMAS IN ADULTS [J].
SEIDEL, G ;
KAPS, M ;
DORNDORF, W .
STROKE, 1993, 24 (10) :1519-1527
[9]  
TSUCHIYA T, 1991, AM J NEURORADIOL, V12, P497