共 30 条
Influence of graphene oxide filler content on the dentin bond integrity, degree of conversion and bond strength of experimental adhesive. A SEM, micro-Raman, FTIR and microtensile study
被引:29
作者:
Bin-Shuwaish, Mohammed S.
[1
]
Maawadh, Ahmed M.
[1
]
Al-Hamdan, Rana S.
[1
]
Alresayes, Saad
[2
]
Ali, Thamer
[3
]
Almutairi, Basil
[1
]
Vohra, Fahim
[2
]
Abduljabbar, Tariq
[2
]
机构:
[1] King Saud Univ, Dept Restorat Dent Sci, Coll Dent, Riyadh 11545, Saudi Arabia
[2] King Saud Univ, Dept Prosthet Dent Sci, Coll Dent, Riyadh, Saudi Arabia
[3] King Saud Univ, Coll Dent, Gen Dent, Riyadh, Saudi Arabia
关键词:
graphene oxide;
dentin bond;
resin adhesive;
degree of conversion;
Micr-Raman Spectroscopy;
bond strength;
ALCOHOL BLEND NANOCOMPOSITES;
ETCH-AND-RINSE;
MECHANICAL-PROPERTIES;
PHOTOPOLYMERIZATION;
SOLVENT;
TIME;
D O I:
10.1088/2053-1591/abcba7
中图分类号:
T [工业技术];
学科分类号:
120111 [工业工程];
摘要:
The study aimed to evaluate the effect of graphene oxide (GO) nano-filler content in experimental dental adhesive on its degree of conversion (DC), microtensile bond strength (mu TBS) and structural reliability, using Fourier transform infrared spectroscopy (FTIR), Micro-Raman spectroscopy and Scanning electron microscopy (SEM). A resin adhesive was fabricated (control adhesive - CA) and fabricated GO nano-particles were added at 0.5% and 2.0% (m/m) to produce adhesives GOA1 and GOA2 respectively. One hundred and two teeth (specimens) were prepared for dentin exposure and conditioned with 36% phosphoric acid. Specimens in each group (n = 34) were treated with formulated adhesives (CA, GOA1 & GOA2) and photo-polymerized for 20 s followed by composite build up. Sixty specimens were used for mu TBS testing in the adhesive groups (CA, GOA1 & GOA2), with half exposed to thermocycling (TC) whereas the remaining half (n = 10) stored in distilled water. Seven specimens each were assessed using SEM and Micro-Raman spectroscopy, in each adhesive group (n = 7). DC for the adhesives was assessed using FTIR. The means of mu TBS and DC were analyzed using ANOVA and post hoc Tukey multiple comparisons test. GO nano-filler content showed significant influence on the adhesive mu TBS in comparison to controls (p < 0.01). Ageing (TC) revealed significant reduction in the mu TBS, except in GOA2 specimens, which showed comparable outcomes among TC and non-TC specimens (p > 0.05). DC was significantly higher in control adhesive [46.8 (3.6)%] compared to GOA2 [37.7 (4.2)%] specimens, however DC was comparable among GOA1 [42.3 (2.9)%] and GOA2 [37.7 (4.2)%] specimens (p > 0.05) respectively. GO exhibited interaction within adhesive and tooth dentin comparable to control adhesive. Increasing GO content showed increase in mu TBS of adhesive to dentin, but a decrease in degree of conversion. Under ideal conditions, experimental adhesive with 2% GO content showed acceptable bond strength and DC; and should be further assessed under dynamic conditions to recommend clinical use.
引用
收藏
页数:13
相关论文

