Review of in vitro studies on the biocompatibility of NiTi alloys

被引:14
作者
Ponsonnet, L. [1 ]
Treheux, D.
Lissac, M.
Jaffrezic, N.
Grosgogeat, B.
机构
[1] Ecole Cent Lyon, CEGELY, UMR 5005, F-69134 Ecully, France
[2] Ecole Cent Lyon, LTDS, UMR 5513, F-69134 Ecully, France
[3] UFR Odontol, LEIBO, EA 637, F-69008 Lyon, France
关键词
corrosion; biocompatibility; alloys (NiTi); orthodontic wires;
D O I
10.3233/JAE-2006-733
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Nickel-Titanium (NiTi) alloys exhibit special mechanical properties known as shape memory effect and superelasticity. The first effect relates to the fact that after deformation at low temperature, the material regains its original shape after heating. The second effect denotes an unusual flexibility of the material that is far greater than the flexibility of common metallic materials. These properties can be put to excellent use in various biomedical applications, such as orthodontic wires, orthopaedic implants for osteosynthesis, stents for various applications, bone substitution materials and experimental systems for scoliosis correction. The purpose of the present review is to analyze in vitro NiTi biocompatibility compared to other titanium alloys. The problem of Ni's possible toxicity is discussed. Corrosion properties in an oral environment are investigated. The effect of surface chemical composition and surface roughness on cell adhesion, morphology and proliferation is shown as an example. Sterilization is taken into account and its influence on roughness and mechanical properties, chemical composition, wettability and bacterial adhesion inhibition is evaluated. The conclusion is that NiTi is at least as biocompatible as conventional titanium due to the TiO2 oxide layer, and that only in special chemical conditions can Ni diffuse out of the NiTi material.
引用
收藏
页码:147 / 151
页数:5
相关论文
共 43 条
[1]  
Al-Waheidi E M, 1995, Quintessence Int, V26, P385
[2]  
ASSAD M, 1994, ANN CHIRURG, V48, P8
[3]   Electrochemical studies on the stability and corrosion resistance of titanium-based implant materials [J].
Aziz-Kerrzo, M ;
Conroy, KG ;
Fenelon, AM ;
Farrell, ST ;
Breslin, CB .
BIOMATERIALS, 2001, 22 (12) :1531-1539
[4]   BIODEGRADATION OF ORTHODONTIC APPLIANCES .1. BIODEGRADATION OF NICKEL AND CHROMIUM INVITRO [J].
BARRETT, RD ;
BISHARA, SE ;
QUINN, JK .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1993, 103 (01) :8-14
[5]   NICKEL HYPERSENSITIVITY IN THE ORTHODONTIC PATIENT [J].
BASS, JK ;
FINE, H ;
CISNEROS, GJ .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1993, 103 (03) :280-285
[6]  
BERTRAND AL, IN PRESS EUR CELLS M
[7]   BIODEGRADATION OF ORTHODONTIC APPLIANCES .2. CHANGES IN THE BLOOD LEVEL OF NICKEL [J].
BISHARA, SE ;
BARRETT, RD ;
SELIM, MI .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1993, 103 (02) :115-119
[8]   On the transformation behaviour, mechanical properties and biocompatibility of two NiTi-based shape memory alloys: NiTi42 and NiTi42Cu7 [J].
Es-Souni, M ;
Es-Souni, M ;
Brandies, HF .
BIOMATERIALS, 2001, 22 (15) :2153-2161
[9]  
Heintz C, 2001, J ENDOVASC THER, V8, P248, DOI 10.1583/1545-1550(2001)008<0248:CNWIEA>2.0.CO
[10]  
2