Decreased Infarct Volume and Intracranial Hemorrhage Associated with Intra-Arterial Nonionic Iso-Osmolar Contrast Material in an MCA Occlusion/Reperfusion Model

被引:7
作者
Morales, H. [1 ]
Lu, A. [2 ]
Kurosawa, Y. [2 ]
Clark, J. F. [2 ]
Leach, J. [1 ]
Weiss, K. [3 ]
Tomsick, T. [1 ]
机构
[1] Univ Cincinnati, Dept Radiol, Cincinnati, OH 45219 USA
[2] Univ Cincinnati, Dept Neurol, Cincinnati, OH 45219 USA
[3] Univ Mississippi, Dept Radiol, Oxford, MS USA
关键词
BLOOD-BRAIN-BARRIER; ACUTE ISCHEMIC-STROKE; CEREBRAL-ARTERY OCCLUSION; INTRACEREBRAL HEMORRHAGE; THROMBOEMBOLIC STROKE; FOCAL ISCHEMIA; RAT-BRAIN; IN-VITRO; MEDIA; TRANSFORMATION;
D O I
10.3174/ajnr.A3953
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Infarct volume and intracranial hemorrhage after reperfusion with nonionic low-osmolar and iso-osmolar iodinated IRCM has not been previously compared. We postulated that iso-osmolar and low-osmolar iodinated contrast media exert varied effects on cerebral infarct after intra-arterial injection. We compared infarct volume and hemorrhagic changes following intra-arterial infusion of iodixanol, iopamidol, or normal saline in a rat MCA occlusion/reperfusion model. MATERIALS AND METHODS: Infarct was induced in 30 rats by a previously validated method of MCA suture occlusion. Reperfusion was performed after 5 hours with either iodixanol (n = 9), iopamidol (n = 12), or saline (n = 9). MR images were obtained at both 6 and 24 hours after ischemia, followed by sacrifice. Infarct volume was measured with T2WI and DWI by semiautomatic segmentation. Incidence and area of hemorrhage were measured on brain sections postmortem. RESULTS: T2WI mean infarct volumes were 242 +/- 9, 324 +/- 70, and 345 +/- 92 mm(3) at 6 hours, and 341 +/- 147,470 +/- 91, and 462 +/- 71 mm(3) at 24 hours in the iodixanol, iopamidol, and saline groups, respectively. Differences in infarct volume among groups were significant at 6 hours (P < .03) and 24 hours (P < .05). In the iodixanol, iopamidol, and saline groups, mean areas for cortical intracranial hemorrhage were 0.8,18.2, and 25.7 mm(2); and 28, 31, and 56.7 mm(2), respectively, for deep intracranial hemorrhage. The differences in intracranial hemorrhage area among groups were statistically significant for cortical intracranial hemorrhage (P < .01). CONCLUSIONS: Intra-arterial infusion of nonionic iso-osmolar iodixanol showed reduced infarct volume and reduced cortical intracranial hemorrhage areas in comparison with nonionic low-osmolar iopamidol and saline. Our results may be relevant in the setting of intra-arterial therapy for acute stroke in humans, warranting further investigation.
引用
收藏
页码:1885 / 1891
页数:7
相关论文
共 50 条
[1]   Effects of iodinated contrast media on blood and endothelium [J].
Aspelin, P ;
Stacul, F ;
Thomsen, HS ;
Morcos, SK ;
van der Molen, AJ .
EUROPEAN RADIOLOGY, 2006, 16 (05) :1041-1049
[2]   Hemorrhagic Transformation of Ischemic Stroke: Prediction with CT Perfusion [J].
Aviv, Richard I. ;
d'Esterre, Christopher D. ;
Murphy, Blake D. ;
Hopyan, Julia J. ;
Buck, Brian ;
Mallia, Gabriella ;
Li, Vivian ;
Zhang, Liying ;
Symons, Sean P. ;
Lee, Ting-Yim .
RADIOLOGY, 2009, 250 (03) :867-877
[3]   Management of acute ischemic stroke [J].
Caulfield, Anna Finley ;
Wijman, Christine A. C. .
NEUROLOGIC CLINICS, 2008, 26 (02) :345-+
[4]   Osmotic therapy - Fact and fiction [J].
Diringer, MN ;
Zazulia, AR .
NEUROCRITICAL CARE, 2004, 1 (02) :219-233
[5]   GLOBAL CEREBRAL-ISCHEMIA IN THE RAT - ONLINE MONITORING OF OXYGEN-FREE RADICAL PRODUCTION USING CHEMILUMINESCENCE IN-VIVO [J].
DIRNAGL, U ;
LINDAUER, U ;
THEM, A ;
SCHREIBER, S ;
PFISTER, HW ;
KOEDEL, U ;
RESZKA, R ;
FREYER, D ;
VILLRINGER, A .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1995, 15 (06) :929-940
[6]   Are iodinated contrast agents detrimental in acute cerebral ischemia? An experimental study in rats [J].
Doerfler, A ;
Engelhorn, T ;
von Kummer, R ;
Weber, J ;
Knauth, M ;
Heiland, S ;
Sartor, K ;
Forsting, M .
RADIOLOGY, 1998, 206 (01) :211-217
[7]   Iomeprol - A review of its use as a contrast medium [J].
Dooley, M ;
Jarvis, B .
DRUGS, 2000, 59 (05) :1169-1186
[8]  
Edvinsson L., 1993, CEREBRAL BLOOD FLOW, P3
[9]   Safety, tolerance, and pharmacokinetics of iodixanol injection, a nonionic, isosmolar, hexa-iodinated contrast agent [J].
Fountaine, H ;
Harnish, P ;
Andrew, E ;
Grynne, B .
ACADEMIC RADIOLOGY, 1996, 3 :S475-S484
[10]   Influence of various radiographic contrast media on the buckling of endothelial cells [J].
Franke, Ralf-Peter ;
Fuhrmann, Rosemarie ;
Hiebl, Bernhard ;
Jung, Friedrich .
MICROVASCULAR RESEARCH, 2008, 76 (02) :110-113