Controlling matrix suppression for matrix-assisted laser desorption/ionization analysis of small molecules

被引:31
作者
Donegan, M [1 ]
Tomlinson, AJ [1 ]
Nair, H [1 ]
Juhasz, P [1 ]
机构
[1] Appl Biosyst Inc, Framingham, MA 01701 USA
关键词
D O I
10.1002/rcm.1568
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The need for high-throughput methodologies providing both qualitative and quantitative information has grown substantially in the pharmaceutical laboratory in recent years. Currently, tandem mass spectrometry (MS/MS) using quadrupole technology offers analysis in the minutes time scale. The use of matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) offers the advantage of speed and automation and enables analysis in the seconds time scale with accurate mass capabilities that are not typically found in quadrupole MS/MS. However, one of the limitations of MALDI for the analysis of small molecules is the abundance of interfering matrix peaks in the low molecular weight region of the mass spectrum. Described herein is an evaluation of a pre-prepared MALDI target plate that has been coated with a thin layer of alpha-cyano-4-hydroxycinnamic acid (CHCA) and nitrocellulose. This modified plate has been shown to suppress or eliminate CHCA matrix signals without any significant loss of analyte sensitivity when compared with analysis of the same sample using an unmodified target plate. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:1885 / 1888
页数:4
相关论文
共 13 条
[1]   Practical quantitative biomedical applications of MALDI-TOF mass spectrometry [J].
Bucknall, M ;
Fung, KYC ;
Duncan, MW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2002, 13 (09) :1015-1027
[2]   Small molecule analysis by MALDI mass spectrometry [J].
Cohen, LH ;
Gusev, AI .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (07) :571-586
[3]   Quantitative analysis with desorption/ionization on silicon mass spectrometry using electrospray deposition [J].
Go, EP ;
Shen, ZX ;
Harris, K ;
Siuzdak, G .
ANALYTICAL CHEMISTRY, 2003, 75 (20) :5475-5479
[4]   Quantitative analysis of small pharmaceutical drugs using a high repetition rate laser matrix-assisted laser/desorption ionization source [J].
Hatsis, P ;
Brombacher, S ;
Corr, J ;
Kovarik, P ;
Volmer, DA .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (20) :2303-2309
[5]   Simultaneous measurement of drug metabolic stability and identification of metabolites using ion-trap mass spectrometry [J].
Kantharaj, E ;
Tuytelaars, A ;
Proost, PEA ;
Ongel, Z ;
van Assouw, HP ;
Gilissen, RAHJ .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (23) :2661-2668
[6]  
Knochenmuss R, 1996, RAPID COMMUN MASS SP, V10, P871, DOI 10.1002/(SICI)1097-0231(19960610)10:8<871::AID-RCM559>3.0.CO
[7]  
2-R
[8]  
Knochenmuss R, 1998, RAPID COMMUN MASS SP, V12, P529, DOI 10.1002/(SICI)1097-0231(19980515)12:9<529::AID-RCM188>3.0.CO
[9]  
2-E
[10]   Ready-made matrix-assisted laser desorption/ionization target plates coated with thin matrix layer for automated sample deposition in high-density array format [J].
Miliotis, T ;
Kjellström, S ;
Nilsson, J ;
Laurell, T ;
Edholm, LE ;
Marko-Varga, G .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (02) :117-126