Evaluation of different keV-settings in dual-energy CT angiography of the aorta using advanced image-based virtual monoenergetic imaging

被引:72
作者
Beeres, Martin [1 ]
Trommer, Jesko [1 ]
Frellesen, Claudia [1 ]
Nour-Eldin, Nour-Eldin A. [1 ,3 ]
Scholtz, Jan E. [1 ]
Herrmann, Eva [2 ]
Vogl, Thomas J. [1 ]
Wichmann, Julian L. [1 ]
机构
[1] Clin Goethe Univ, Dept Diagnost & Intervent Radiol, D-60590 Frankfurt, Germany
[2] Clin Goethe Univ, Dept Biostat, D-60590 Frankfurt, Germany
[3] Cairo Univ Hosp, Dept Diagnost & Intervent Radiol, Cairo, Egypt
关键词
CT angiography; Aorta; Dual energy CT; Virtual monoenergetic imaging; Image noise; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; CONTRAST-MEDIA; QUALITY; OPTIMIZATION; PHANTOM;
D O I
10.1007/s10554-015-0728-5
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
To compare quantitative image quality in dual-energy CT angiography (DE-CTA) studies of the aorta using different virtual monoenergetic imaging (MEI) and advanced image-based virtual monoenergetic (MEI+) settings at varying kiloelectron volt (keV) levels. Fifty consecutive patients with clinically-indicated CT of the whole aorta to evaluate suspected aortic disease underwent DE-CTA on a third-generation dual-source CT scanner. Quantitative image quality indices were assessed. Contrast material, saline flush and flow rate were kept equal for optimum comparability. DE-CTA MEI and MEI+ series ranging from 40 to 100 keV (10-keV intervals) were reconstructed. Signal intensity, noise, signal-to-noise ratio and contrast-to-noise ratio (CNR) of multiple aortic segments were evaluated. Comparisons between the different MEI and MEI+ datasets were performed. Three-hundred aortic segments total were evaluated. In the MEI+ series the 40, 50 and 100 keV MEI+ showed superior noise and CNR levels (+84, +58, +103 % on average; all p < 0.05) compared to MEI. However, signal intensity between MEI+ and MEI at nearly all aortic segments showed no significant difference (p > 0.1). MEI+ shows lower image noise compared to MEI, resulting in superior quantitative image quality, in particular at low keV levels (40 or 50 keV).
引用
收藏
页码:137 / 144
页数:8
相关论文
共 17 条
[1]
Assessment of an Advanced Monoenergetic Reconstruction Technique in Dual-Energy Computed Tomography of Head and Neck Cancer [J].
Albrecht, Moritz H. ;
Scholtz, Jan-Erik ;
Kraft, Johannes ;
Bauer, Ralf W. ;
Kaup, Moritz ;
Dewes, Patricia ;
Bucher, Andreas M. ;
Burck, Iris ;
Wagenblast, Jens ;
Lehnert, Thomas ;
Kerl, J. Matthias ;
Vogl, Thomas J. ;
Wichmann, Julian L. .
EUROPEAN RADIOLOGY, 2015, 25 (08) :2493-2501
[2]
Value of monoenergetic low-kV dual energy CT datasets for improved image quality of CT pulmonary angiography [J].
Apfaltrer, Paul ;
Sudarski, Sonja ;
Schneider, David ;
Nance, John W., Jr. ;
Haubenreisser, Holger ;
Fink, Christian ;
Schoenberg, Stefan O. ;
Henzler, Thomas .
EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (02) :322-328
[3]
Noise-optimized virtual monoenergetic images and iodine maps for the detection of venous thrombosis in second-generation dual-energy CT (DECT): an ex vivo phantom study [J].
Bongers, Malte N. ;
Schabel, Christoph ;
Krauss, Bernhard ;
Tsiflikas, Ilias ;
Ketelsen, Dominik ;
Mangold, Stefanie ;
Claussen, Claus D. ;
Nikolaou, Konstantin ;
Thomas, Christoph .
EUROPEAN RADIOLOGY, 2015, 25 (06) :1655-1664
[4]
Substantial iodine volume load reduction in CT angiography with dual-energy imaging: insights from a pilot randomized study [J].
Carrascosa, Patricia ;
Capunay, Carlos ;
Rodriguez-Granillo, Gaston A. ;
Deviggiano, Alejandro ;
Vallejos, Javier ;
Leipsic, Jonathon A. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (08) :1613-1620
[5]
Spectral Optimization of Chest CT Angiography with Reduced Iodine Load: Experience in 80 Patients Evaluated with Dual-Source, Dual-Energy CT [J].
Delesalle, Marie-Aurelie ;
Pontana, Francois ;
Duhamel, Alain ;
Faivre, Jean-Baptiste ;
Flohr, Thomas ;
Tacelli, Nunzia ;
Remy, Jacques ;
Remy-Jardin, Martine .
RADIOLOGY, 2013, 267 (01) :256-266
[6]
Assessment of an Advanced Image-Based Technique to Calculate Virtual Monoenergetic Computed Tomographic Images From a Dual-Energy Examination to Improve Contrast-To-Noise Ratio in Examinations Using Iodinated Contrast Media [J].
Grant, Katharine L. ;
Flohr, Thomas G. ;
Krauss, Bernhard ;
Sedlmair, Martin ;
Thomas, Christoph ;
Schmidt, Bernhard .
INVESTIGATIVE RADIOLOGY, 2014, 49 (09) :586-592
[7]
Dual-energy CT angiography of abdomen with routine concentration contrast agent in comparison with conventional single-energy CT with high concentration contrast agent [J].
He, Jingzhen ;
Wang, Qing ;
Ma, Xiangxing ;
Sun, Zhiyuan .
EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (02) :221-227
[8]
Low kV settings CT angiography (CTA) with low dose contrast medium volume protocol in the assessment of thoracic and abdominal aorta disease: a feasibility study [J].
Ippolito, D. ;
Franzesi, C. Talei ;
Fior, D. ;
Bonaffini, P. A. ;
Minutolo, O. ;
Sironi, S. .
BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1049)
[9]
Coronary computed tomography angiography using ultra-low-dose contrast media: radiation dose and image quality [J].
Komatsu, Sei ;
Kamata, Teruaki ;
Imai, Atsuko ;
Ohara, Tomoki ;
Takewa, Mitsuhiko ;
Ohe, Ryoko ;
Miyaji, Kazuaki ;
Yoshida, Junichi ;
Kodama, Kazuhisa .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (06) :1335-1340
[10]
State of the Art: Dual-Energy CT of the Abdomen [J].
Marin, Daniele ;
Boll, Daniel T. ;
Mileto, Achille ;
Nelson, Rendon C. .
RADIOLOGY, 2014, 271 (02) :327-342