Electrocardiogram-gated single-photon emission computed tomography versus cardiac magnetic resonance imaging for the assessment of left ventricular volumes and ejection fraction - A meta-analysis

被引:90
作者
Ioannidis, JPA
Trikalinos, TA
Danias, PG
机构
[1] Beth Israel Deaconess Med Ctr, Div Cardiol, Dept Med, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Univ Ioannina, Sch Med, Dept Hyg & Epidemiol, Clin Trials & Evidence Based Med Unit, GR-45110 Ioannina, Greece
[4] Univ Ioannina, Sch Med, Dept Hyg & Epidemiol, Clin & Mol Epidemiol Unit, GR-45110 Ioannina, Greece
[5] Tufts Univ, Sch Med, Dept Med, Boston, MA 02111 USA
关键词
D O I
10.1016/S0735-1097(02)01882-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The purpose of this study was to evaluate the accuracy of electrocardiogram (ECG)-gated single-photon emission computed tomography (SPECT) for assessment of left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) compared with the gold standard of cardiac magnetic resonance imaging (MRI). BACKGROUND Several comparisons of ECG-gated SPECT with cardiac MRI have been performed for evaluation of LV volumes and EF, but each has considered few subjects, thus leaving uncertainty about the frequency of discrepancies between the two methods. METHODS We performed a meta-analysis of data on 164 subjects from nine studies comparing ECG-gated SPECT versus cardiac MRI. Data were pooled in correlation and regression analyses relating ECG-gated SPECT and cardiac MRI measurements. The frequency of discrepancies of at least 30 ml in EDV, 20 ml in ESV and 5% or 10% in EF and concordance for EF less than or equal to40% versus >40% were determined. RESULTS There was an overall excellent correlation between ECG-gated SPECT and cardiac MRI for EDV (r = 0.89), ESV (r = 0.92) and EF (r = 0.87). However, rates of discrepancies for individual subjects were considerable (37% [95% confidence interval [CI], 26% to 50%] for at least 30 ml in EDV; 35% [95% CI, 23% to 49%] for at least 20 ml in ESV; 52% [95% CI, 37% to 63%] for at least 5% in EF; and 23% [95% CI, 11% to 42%] for at least 10% in EF). The misclassification rate for the 40% EF cutoff was 11%. CONCLUSIONS Electrocardiogram-gated SPECT measurements of EDV, ESV and EF show high correlation with cardiac MRI measurements, but substantial errors may occur in individual patients. Electrocardiogram-gated SPECT offers useful functional information, but cardiac MRI should be used when accurate measurement is required.
引用
收藏
页码:2059 / 2068
页数:10
相关论文
共 35 条
[11]  
Fleiss JL, 1981, STAT METHODS RATES P
[12]  
GERMANO G, 1995, J NUCL MED, V36, P1107
[13]   Is the addition of ECG gating to technetium-99m sestamibi SPET of value in the assessment of myocardial viability? An evaluation based on two-dimensional echocardiography following revascularization [J].
Gonzalez, P ;
Massardo, T ;
Munoz, A ;
Jofre, J ;
Rivera, A ;
Yovanovich, J ;
Maiers, E ;
Ayala, F ;
Humeres, P ;
Ramirez, A ;
Arriagada, M ;
Zavala, A .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1996, 23 (10) :1315-1322
[14]  
Gunning MG, 1997, J NUCL MED, V38, P438
[15]   Simultaneous assessment of myocardial viability and function for the detection of hibernating myocardium using ECG-gated 99Tcm-tetrofosmin emission tomography:: A comparison with 201Tl emission tomography combined with cine magnetic resonance imaging [J].
Gunning, MG ;
Anagnostopoulos, C ;
Davies, G ;
Knight, CJ ;
Pennell, DJ ;
Fox, KM ;
Pepper, J ;
Underwood, SR .
NUCLEAR MEDICINE COMMUNICATIONS, 1999, 20 (03) :209-214
[16]   Reproducibility of Tl-201 and Tc-99m sestamibi gated myocardial perfusion SPECT measurement of myocardial function [J].
Hyun, IY ;
Kwan, J ;
Park, KS ;
Lee, WH .
JOURNAL OF NUCLEAR CARDIOLOGY, 2001, 8 (02) :182-187
[17]   LEFT-VENTRICULAR DILATATION AND PULMONARY THALLIUM UPTAKE AFTER SINGLE-PHOTON EMISSION COMPUTER-TOMOGRAPHY USING TL-201 DURING ADENOSINE-INDUCED CORONARY HYPEREMIA [J].
ISKANDRIAN, AS ;
HEO, J ;
THACH, NY ;
LYONS, E ;
PAUGH, E .
AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (10) :807-811
[18]   Functional assessment with electrocardiographic gated single-photon emission computed tomograph improves the ability of technetium-99m sestamibi myocardial perfusion imaging to predict myocardial viability in patients undergoing revascularization [J].
Levine, MG ;
McGill, CC ;
Ahlberg, AW ;
White, MP ;
Giri, S ;
Shareef, B ;
Waters, D ;
Heller, GV .
AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (01) :1-5
[19]   Transient left ventricular dilation at quantitative stress-rest sestamibi tomography: Clinical, electrocardiographic, and angiographic correlates [J].
Marcassa, C ;
Galli, M ;
Baroffio, C ;
Campini, R ;
Giannuzzi, P .
JOURNAL OF NUCLEAR CARDIOLOGY, 1999, 6 (04) :397-405
[20]  
Mochizuki T, 1997, J NUCL MED, V38, P53