Patch test reactions to Biobans in metalworkers are often weak and not reproducible

被引:18
作者
Brinkmeier, T
Geier, J
Lepoittevin, JP
Frosch, PJ
机构
[1] Klinikum Dortmund gGmbH, Hautklin, Dept Dermatol, D-44137 Dortmund, Germany
[2] Univ Strasbourg 1, Lab Dermatochim, Strasbourg, France
关键词
allergic contact dermatitis; antibacterials; Biobans; biocides; formaldehyde-releasers; metalworkers; occupational; patch testing technique; preservatives; reproducibility;
D O I
10.1034/j.1600-0536.2002.470106.x
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Contact allergy to the industrial preservative group of Biobans has been reported in individual cases. We have performed a prospective study on 408 metalworkers who were tested with 6 different Biobans, formaldehyde and 5 other preservatives. Furthermore, retesting was performed after a time interval of 6 months to 4 years. The test results were also compared with those of the multicentric data provided by the Information Network of Departments of Dermatology in Germany and Austria (IVDK), particularly with regard to cross-reactivity between the various Biobans and formaldehyde. In 408 metalworkers 14 (3.4%) showed positive reactions to Biobans (2.2% P 1487, 2.0% CS 1246, 1.5% CS 1135), the majority being + reactions. On retesting 10 patients, the reactions were confirmed in only 2 cases (P 1487 and CS 1135). 4 patients showed positive reactions to 3 Biobans (P 1487, CS 1135, CS 1246), while 9 patients had only solitary sensitizations. Concomitant sensitization to formaldehyde was present in 5 out of 10 patients, being reproducible in 3 of them. In the IVDK data, sensitization prevalence in 3400 patients ranged from 1.8% (P 1487) to 0.8% (CS 1246). A high proportion of doubtful or irritant reactions as well as weak + reactions was observed. Cross-reactivity between the various Biobans was low, moderate agreement being calculated for CS 1135 and CS 1246 (kappa coefficient 0.43). The consensus pattern between formaldehyde and the tested Biobans was even lower. In conclusion, patch test reactions to Biobans are not rare among metalworkers but are often weak and not reproducible. Simultaneous reactivity to various Biobans and formaldehyde may be due to cross-reactivity or cosensitization from common exposure.
引用
收藏
页码:27 / 31
页数:5
相关论文
共 14 条
[1]   REPRODUCIBILITY OF PATCH TESTS - A MULTICENTER STUDY OF SYNCHRONOUS LEFT-SIDED VERSUS RIGHT-SIDED PATCH TESTS BY THE GERMAN-CONTACT-DERMATITIS-RESEARCH-GROUP [J].
BRASCH, J ;
HENSELER, T ;
ABERER, W ;
BAUERLE, G ;
FROSCH, PJ ;
FUCHS, T ;
FUNFSTUCK, V ;
KAISER, G ;
LISCHKA, GG ;
PILZ, B ;
SAUER, C ;
SCHALLER, J ;
SCHEUER, B ;
SZLISKA, C .
JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 1994, 31 (04) :584-591
[2]  
BREHLER R, 1995, DTSCH DERMATOLOGE, V43, P688
[3]   ALLERGIC CONTACT-DERMATITIS FROM BIOBANS IN SPANISH METAL WORKERS [J].
CAMARASA, JG ;
ROMAGUERA, C ;
SERRABALDRICH, E ;
VILAPLANA, J .
CONTACT DERMATITIS, 1993, 29 (02) :98-98
[4]   CONTACT ALLERGY TO THE CUTTING OIL PRESERVATIVES BIOBAN CS-1246 AND P-1487 [J].
DAHLQUIST, I .
CONTACT DERMATITIS, 1984, 10 (01) :46-46
[5]   CONTACT ALLERGY TO PRESERVATIVES .1. [J].
DEGROOT, AC ;
WEYLAND, JW ;
BOS, JD ;
JAGTMAN, BA .
CONTACT DERMATITIS, 1986, 14 (02) :120-122
[6]   CONTACT ALLERGY TO BRONOPOL [J].
FROSCH, PJ ;
WHITE, IR ;
RYCROFT, RJG ;
LAHTI, A ;
BURROWS, D ;
CAMARASA, JG ;
DUCOMBS, G ;
WILKINSON, JD .
CONTACT DERMATITIS, 1990, 22 (01) :24-26
[7]  
Geier J, 1997, ALLERGOLOGIE, V20, P215
[8]  
Geier J., 2000, DERMATOL BERUF UMWEL, V48, P232
[9]   Contact allergy to the active ingredients of Bioban P 1487 [J].
Gruvberger, B ;
Bruze, M ;
Zimerson, E .
CONTACT DERMATITIS, 1996, 35 (03) :141-145
[10]   PATCH TESTING WITH PRESERVATIVES AT ST-JOHNS FROM 1982 TO 1993 [J].
JACOBS, MC ;
WHITE, IR ;
RYCROFT, RJG ;
TAUB, N .
CONTACT DERMATITIS, 1995, 33 (04) :247-254