Fetal ventricular mass determination on three-dimensional echocardiography - Studies in normal fetuses and validation experiments

被引:44
作者
Bhat, AH [1 ]
Corbett, V [1 ]
Carpenter, N [1 ]
Liu, N [1 ]
Liu, RL [1 ]
Wu, A [1 ]
Hopkins, G [1 ]
Sohaey, R [1 ]
Winkler, C [1 ]
Sahn, CS [1 ]
Sovinsky, V [1 ]
Li, XK [1 ]
Sahn, DJ [1 ]
机构
[1] Oregon Hlth & Sci Univ, Clin Care Ctr Congenital Heart Dis, Portland, OR 97239 USA
关键词
echocardiography; fetal; imaging; fetus; heart defects; congenital;
D O I
10.1161/01.CIR.0000139848.33468.22
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Estimation of ventricular volume and mass is important for baseline and serial evaluation of fetuses with normal or abnormal hearts. Direct measurement of chamber wall volumes and mass can be made without geometric assumptions by 3D fetal echocardiography. Our goals were to determine the feasibility of using fast nongated 3D echocardiography for fetal volumetric and mass assessments, to validate the accuracy of the ultrasound system and the measurement technique, and if satisfactory, to develop normal values for fetal ventricular mass during the second and third trimesters. Methods and Results-This was a prospective outpatient study of 90 consecutive normal pregnancies during routine obstetric services at Oregon Health & Science University (Portland). Optimized 3D volumes of the fetal thorax and cardiac chambers were rapidly acquired and later analyzed for right and left ventricular mass by radial summation technique from manual epicardial and endocardial traces. Experiments to validate the ultrasound system and measurement technique were performed with modified small balloon models and in vivo and ex vivo small animal experiments. Our study established the feasibility of fetal ventricular mass measurements with 3D ultrasound technology and developed normal values for right and left ventricular mass from 15 weeks' gestation to term. Conclusions-Nongated fast 3D fetal echocardiography is an acceptable modality for determination of cardiac chamber wall volume and mass with good accuracy and acceptable interobserver variability. The method should be especially valuable as an objective serial measurement in clinical fetal studies with structurally or functionally abnormal hearts.
引用
收藏
页码:1054 / 1060
页数:7
相关论文
共 34 条
[1]   Comparison of three-dimensional echocardiographic assessment of volume, mass, and function in children with functionally single left ventricles with two-dimensional echocardiography and magnetic resonance imaging [J].
Altmann, K ;
Shen, ZQ ;
Boxt, LM ;
King, DL ;
Gersony, WM ;
Allan, LD ;
Apfel, HD .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (08) :1060-1065
[2]   Quantitative three dimensional echocardiography in patients with pulmonary hypertension and compressed left ventricles: Comparison with cross sectional echocardiography and magnetic resonance Imaging [J].
Apfel, HD ;
Shen, ZQ ;
Gopal, AS ;
Vangi, V ;
Solowiejczyk, D ;
Altmann, K ;
Barst, RJ ;
Boxt, LM ;
Allan, LD ;
King, DL .
HEART, 1996, 76 (04) :350-354
[3]   In utero programming of cardiovascular disease [J].
Barker, DJP .
THERIOGENOLOGY, 2000, 53 (02) :555-574
[4]   FETAL ORIGINS OF CORONARY HEART-DISEASE [J].
BARKER, DJP .
BRITISH MEDICAL JOURNAL, 1995, 311 (6998) :171-174
[5]   Three-dimensional US assessment of hepatic volume, head circumference, and abdominal circumference in healthy and growth-restricted fetuses [J].
Boito, SME ;
Laudy, JAM ;
Struijk, PC ;
Stijnen, T ;
Wladimiroff, JW .
RADIOLOGY, 2002, 223 (03) :661-665
[6]   Assessment of fetal cerebellar volume using three-dimensional ultrasound [J].
Chang, CH ;
Chang, FM ;
Yu, CH ;
Ko, HC ;
Chen, HY .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (06) :981-988
[7]   Fetal heart volume assessment by three-dimensional ultrasound [J].
Chang, FM ;
Hsu, KF ;
Ko, HC ;
Yao, BL ;
Chang, CH ;
Yu, CH ;
Liang, TI ;
Chen, HY .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1997, 9 (01) :42-48
[8]   ECHOCARDIOGRAPHIC DETERMINATION OF LEFT-VENTRICULAR MASS IN MAN - ANATOMIC VALIDATION OF METHOD [J].
DEVEREUX, RB ;
REICHEK, N .
CIRCULATION, 1977, 55 (04) :613-618
[9]  
DEVORE GR, 1985, J ULTRAS MED, V4, P335
[10]  
Endres LK, 2001, J ULTRAS MED, V20, P1265