Posterior percutaneous spine instrumentation

被引:58
作者
Lowery, GL [1 ]
Kulkarni, SS [1 ]
机构
[1] Res Inst Int Inc, Gainesville, FL 32608 USA
关键词
minimally invasive; posterior instrumentation; percutaneous; suprafascial; pedicle screw;
D O I
10.1007/PL00008318
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Eighty consecutive cases of suprafascial pedicle screw stabilization were reviewed. Intraoperative fluoroscopy aided the percutaneous screw placement after structural anterior interbody graft(s) were placed. During routine outpatient hardware removal, all intradiscal fusions were stressed via the Shanz screws under fluoroscopy. Anterior reconstruction via a mini open approach coupled with this minimally invasive posterior approach led to a 96% successful fusion rate.
引用
收藏
页码:S126 / S130
页数:5
相关论文
共 21 条
  • [1] AEBI M, 1988, CLIN ORTHOP RELAT R, P30
  • [2] Airaksinen O, 1996, Eur Spine J, V5, P193, DOI 10.1007/BF00395513
  • [3] A CARBON-FIBER IMPLANT TO AID INTERBODY LUMBAR FUSION - 2-YEAR CLINICAL-RESULTS IN THE 1ST 26 PATIENTS
    BRANTIGAN, JW
    STEFFEE, AD
    [J]. SPINE, 1993, 18 (14) : 2106 - 2117
  • [4] The use of bone allografts in the spine
    Buttermann, GR
    Glazer, PA
    Bradford, DS
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1996, (324) : 75 - 85
  • [5] THE FIXATUER-INTERNE AS A VERSATILE IMPLANT FOR SPINE SURGERY
    DICK, W
    [J]. SPINE, 1987, 12 (09) : 882 - 900
  • [6] A MODIFIED MUSCLE-SPLITTING APPROACH TO THE LUMBOSACRAL SPINE
    FRASER, RD
    GOGAN, WJ
    [J]. SPINE, 1992, 17 (08) : 943 - 948
  • [7] Haaker R G, 1997, Eur Spine J, V6, P125
  • [8] JEANNERET B, 1994, CLIN ORTHOP RELAT R, P130
  • [9] KAMBIN P, 1995, ROLE MINIMALLY INVAS, V3, P147
  • [10] INTERSPACE DISTRACTION AND GRAFT SUBSIDENCE AFTER ANTERIOR LUMBAR FUSION WITH FEMORAL STRUT ALLOGRAFT
    KUMAR, A
    KOZAK, JA
    DOHERTY, BJ
    DICKSON, JH
    [J]. SPINE, 1993, 18 (16) : 2393 - 2400