Ratio of Tumor to Normal Prostate Tissue Apparent Diffusion Coefficient as a Method for Quantifying DWI of the Prostate

被引:59
作者
Barrett, Tristan [1 ,2 ]
Priest, Andrew N. [1 ,2 ]
Lawrence, Edward M. [1 ,2 ]
Goldman, Debra A. [3 ]
Warren, Anne Y. [2 ,4 ]
Gnanapragasam, Vincent J. [5 ,6 ]
Sala, Evis [1 ,2 ]
Gallagher, Ferdia A. [1 ,2 ]
机构
[1] Addenbrookes Hosp, Dept Radiol, Cambridge CB2 0QQ, England
[2] Univ Cambridge, Cambridge CB2 0QQ, England
[3] Mem Sloan Kettering Canc Ctr, Dept Biostat & Epidemiol, New York, NY 10021 USA
[4] Addenbrookes Hosp, Dept Histopathol, Cambridge CB2 2QQ, England
[5] Addenbrookes Hosp, Dept Urol, Cambridge CB2 2QQ, England
[6] Univ Cambridge, Translat Prostate Canc Grp, Hutchinson MRC Res Ctr, Dept Oncol, Cambridge, England
基金
英国工程与自然科学研究理事会;
关键词
DWI; Gleason score; MRI; prostate cancer; CANCER AGGRESSIVENESS; B VALUES; RADICAL PROSTATECTOMY; GLEASON GRADE; WEIGHTED MRI; DIAGNOSIS; PATHOLOGY; BIOMARKER; FEATURES; UTILITY;
D O I
10.2214/AJR.15.14338
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
OBJECTIVE. The purpose of this study was to investigate the ability of the apparent diffusion coefficient (ADC) ratio of tumor to normal prostate tissue to overcome inherent variability based on choice of b values, with whole-mount histopathologic analysis as the reference standard for tumor identification. MATERIALS AND METHODS. Thirty-nine patients with prostate cancer underwent 3-T MRI, including DWI with b values of 0, 150, 750, and 1000 s/mm(2). ADC maps were derived from four b value combinations. Histologically derived ROIs were defined for prostate tumor and benign prostate tissue to generate a ratio. The concordance correlation coefficient was used to evaluate agreement and reproducibility at different b values. Bland-Altman plots were used to evaluate the pattern of relative measurement difference between b value combinations. The relationship between ADC values and Gleason score was tested by Spearman rank correlation. RESULTS. ADC values varied depending on the b value combination selected. The concordance correlation coefficient was higher for ADC ratios (0.883; 95% CI, 0.816-0.927) compared with absolute ADC values for normal tissue (0.873; 95% CI, 0.799-0.921) and tumor (0.792; 95% CI, 0.688-0.864). The ADC ratio concordance correlation coefficient for transition zone tumors was considerably higher than that for the peripheral zone in all cases. Bland-Altman analysis showed higher variation for ADC maps incorporating a b value of zero for both ratio and absolute values. There was a stronger inverse relationship to Gleason score for ADC ratios (rho, -0.354 to -0.456) compared with absolute ADC values (rho, -0.117 to -0.379). CONCLUSION. The use of a simple ratio of prostate tumor ADC to normal tissue ADC improved the concordance between different b value combinations and could provide a more robust means of assessing restricted diffusion in the prostate.
引用
收藏
页码:W585 / W593
页数:9
相关论文
共 29 条
[1]
Apparent diffusion coefficient value as a biomarker reflecting morphological and biological features of prostate cancer [J].
Bae, Hyeyeol ;
Yoshida, Soichiro ;
Matsuoka, Yoh ;
Nakajima, Hiroshi ;
Ito, Eisaku ;
Tanaka, Hiroshi ;
Oya, Miyako ;
Nakayama, Takayuki ;
Takeshita, Hideki ;
Kijima, Toshiki ;
Ishioka, Junichiro ;
Numao, Noboru ;
Koga, Fumitaka ;
Saito, Kazutaka ;
Akashi, Takumi ;
Fujii, Yasuhisa ;
Kihara, Kazunori .
INTERNATIONAL UROLOGY AND NEPHROLOGY, 2014, 46 (03) :555-561
[2]
ESUR prostate MR guidelines 2012 [J].
Barentsz, Jelle O. ;
Richenberg, Jonathan ;
Clements, Richard ;
Choyke, Peter ;
Verma, Sadhna ;
Villeirs, Geert ;
Rouviere, Olivier ;
Logager, Vibeke ;
Futterer, Jurgen J. .
EUROPEAN RADIOLOGY, 2012, 22 (04) :746-757
[3]
Value of the Hemorrhage Exclusion Sign on T1-weighted Prostate MR Images for the Detection of Prostate Cancer [J].
Barrett, Tristan ;
Vargas, Hebert Alberto ;
Akin, Oguz ;
Goldman, Debra A. ;
Hricak, Hedvig .
RADIOLOGY, 2012, 263 (03) :751-757
[4]
Apparent diffusion coefficient ratio correlates significantly with prostate cancer gleason score at final pathology [J].
Boesen, Lars ;
Chabanova, Elizaveta ;
Logager, Vibeke ;
Balslev, Ingegerd ;
Thomsen, Henrik S. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (02) :446-453
[5]
Short- and Midterm Reproducibility of Apparent Diffusion Coefficient Measurements at 3.0-T Diffusion-weighted Imaging of the Abdomen [J].
Braithwaite, Adam C. ;
Dale, Brian M. ;
Boll, Daniel T. ;
Merkle, Elmar M. .
RADIOLOGY, 2009, 250 (02) :459-465
[6]
Estimating the generalized concordance correlation coefficient through variance components [J].
Carrasco, JL ;
Jover, L .
BIOMETRICS, 2003, 59 (04) :849-858
[7]
Chawalparit Orasa, 2013, Journal of the Medical Association of Thailand, V96, P1365
[8]
DeLano MC, 2000, AM J NEURORADIOL, V21, P1830
[9]
Prostate Cancer Aggressiveness: Assessment with Whole-Lesion Histogram Analysis of the Apparent Diffusion Coefficient [J].
Donati, Olivio F. ;
Mazaheri, Yousef ;
Afaq, Asim ;
Vargas, Hebert A. ;
Zheng, Junting ;
Moskowitz, Chaya S. ;
Hricak, Hedvig ;
Akin, Oguz .
RADIOLOGY, 2014, 271 (01) :143-152
[10]
Utility of diffusion-weighted MRI in the diagnosis of bladder carcinoma [J].
Halefoglu, Ahmet Mesrur ;
Sen, Evren Yildiz ;
Tanriverdi, Orhan ;
Yilmaz, Fikriye .
CLINICAL IMAGING, 2013, 37 (06) :1077-1083