Adaptive optical three-dimensional measurement with structured light

被引:92
作者
Kowarschik, R [1 ]
Kuhmstedt, P
Gerber, J
Schreiber, W
Notni, G
机构
[1] Univ Jena, Inst Appl Opt, D-07743 Jena, Germany
[2] Fraunhofer Inst Appl Opt & Precis Engn, D-07745 Jena, Germany
关键词
adaptive optical three-dimensional measurement system; structured light; gray code; uniform scale representation; phase measurement; calibration method development;
D O I
10.1117/1.602346
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The described 3-D measurement system with fringe projection applies the principle of uniform scale representation by the exclusive use of phase measurement values for the coordinates of each point. The test object is successively illuminated with a grating structure from at least three different directions with a telecentric system, where gray code is combined with five 90-deg phase shifts. A CCD camera records the intensity distribution of the fringes that appear as intersection lines on the surface of the object. This provides the linearly independent absolute phase values that are necessary for the calculation of the coordinates. Note that all coordinates (x,y,z) are determined with the same accuracy. To compensate the influence of specular reflections or shadowed areas up to 15 light projection directions can be used. Moreover, the object can be rotated around a second axis, yielding other views of the object. Thus we acquire different patches of the object that are transformed into a global coordinate system without any interactive user help. During this procedure, correlation methods or special points are not necessary. The calibration of the 3-D orientation of the second axis is realized with a special calibration body. (C) 2000 Society of Photo-Optical Instrumentation Engineers. [S0091-3286(00)01701-3].
引用
收藏
页码:150 / 158
页数:9
相关论文
共 19 条
[11]  
KUHMSTEDT P, 1997, P SOC PHOTO-OPT INS, V3100, P261
[12]  
Malz R. W., 1995, OPTICAL 3D MEASUREME, VIII, P194
[13]  
MARK RP, 1997, OPTICAL 3D MEASUREME, V4
[14]  
NADEBORN W, 1993, P SOC PHOTO-OPT INS, P928
[15]   STATISTICAL-ANALYSIS OF ERRORS IN HOLOGRAPHIC-INTERFEROMETRY [J].
NOBIS, D ;
VEST, CM .
APPLIED OPTICS, 1978, 17 (14) :2198-2204
[16]   MEASURES OF FEELING-OF-KNOWING ACCURACY - A NEW LOOK AT AN OLD PROBLEM [J].
SCHRAW, G .
APPLIED COGNITIVE PSYCHOLOGY, 1995, 9 (04) :321-332
[17]  
SCHREIBER W, 1996, P SOC PHOTO-OPT INS, V2782, P600
[18]   ADVANCED EVALUATION TECHNIQUES IN INTERFEROMETRY [J].
SCHWIDER, J .
PROGRESS IN OPTICS, 1990, 28 :271-359
[19]  
STEINBICHLER H, 1994, P SOC PHOTO-OPT INS, V2249, P130