Stabilizing potential of anterior cervical plates in multilevel corpectomies

被引:60
作者
Isomi, T
Panjabi, MM
Wang, JL
Vaccaro, AR
Garfin, SR
Patel, T
机构
[1] Yale Univ, Sch Med, Dept Orthopaed & Rehabil, Biomech Lab, New Haven, CT 06520 USA
[2] St Marianna Univ, Sch Med, Dept Orthopaed, Kanagawa, Japan
[3] Thomas Jefferson Univ, Dept Orthopaed Surg, Philadelphia, PA 19107 USA
[4] Univ Calif San Diego, Med Ctr, Dept Orthopaed, San Diego, CA 92103 USA
关键词
anterior plate surgery; biomechanics; cervical spine; spinal instrumentation; spinal stability;
D O I
10.1097/00007632-199911010-00008
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. An in vitro investigation of three-dimensional kinematics of cervical spine models of one- and three level corpectomy with anterior plate fixation. Objectives. To evaluate the capability of an anterior plate to stabilize the reconstructed cervical spine under simulated physiologic motions, and to study the effects of fatigue loading. Summary of Background Data. Clinical studies have found high failure rates of multilevel anterior cervical plate fusions, indicating suboptimal stabilization. However, no biomechanical studies have been done to investigate the stabilizing capabilities of long-plate instrumentations in corpectomy models. Methods. Seven fresh human cadaveric cervical spine specimens (C2-T1) were used. Flexibility tests consisted of flexion, extension, and bilateral torsion, and lateral bending, each with a pure moment of 0.25, 0.5, 0.75, and 1.0 Nm. Stabilizing potential indices [(Motion(Intact) - Motion(Instrumented))/Motion(Intact)] for ranges of motion and neutral zones obtained from the flexibility tests, were measured when the specimen was intact and after one-level (C5) and three-level (C4, C5, and C6) corpectomies and anterior plate stabilizations). The stabilizing potential indices were re-measured after a 1000-cycle fatigue loading (1 Nm flexion and extension moments at C5 vertebra at 0.14 Hz). Results. The differences in stabilizing potential indices of range of motion and neutral zone between one-level and three-level plates were not significant before fatigue. However, after fatigue, the stabilizing potential indices significantly decreased (P < 0.05) for the three-level model, but not for the one-level plate model. Conclusions. The capability of an anterior cervical plate to stabilize the spine after three-level corpectomy was significantly reduced with fatigue loading.
引用
收藏
页码:2219 / 2223
页数:5
相关论文
共 26 条
[1]
Anterior cervical fusion using Caspar plating: Analysis of results and review of the literature [J].
Bose, B .
SURGICAL NEUROLOGY, 1998, 49 (01) :25-31
[2]
CERVICAL STABILIZATION BY PLATE AND BONE FUSION [J].
BROWN, JA ;
HAVEL, P ;
EBRAHEIM, N ;
GREENBLATT, SH ;
JACKSON, WT .
SPINE, 1988, 13 (03) :236-240
[3]
CINE RADIOGRAPHY IN CERVICAL SPONDYLOSIS AS A MEANS OF DETERMINING THE LEVEL FOR ANTERIOR FUSION [J].
BRUNTON, FJ ;
WILKINSON, JA ;
WISE, KSH ;
SIMONIS, RB .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1982, 64 (04) :399-404
[4]
Biomechanical evaluation of subcortical versus bicortical screw purchase in anterior cervical plating [J].
Chen, IH .
ACTA NEUROCHIRURGICA, 1996, 138 (02) :167-173
[5]
Biomechanical evaluation of Caspar and Cervical Spine Locking Plate systems in a cadaveric model [J].
Clausen, JD ;
Ryken, TC ;
Traynelis, VC ;
Sawin, PD ;
Dexter, F ;
Goel, VK .
JOURNAL OF NEUROSURGERY, 1996, 84 (06) :1039-1045
[6]
Connolly PJ, 1996, J SPINAL DISORD, V9, P202
[7]
ANTERIOR PLATE FIXATION OF TRAUMATIC LESIONS OF THE LOWER CERVICAL-SPINE [J].
DEOLIVEIRA, JC .
SPINE, 1987, 12 (04) :324-329
[8]
PSEUDARTHROSIS OF THE CERVICAL-SPINE AFTER ANTERIOR ARTHRODESIS - TREATMENT BY POSTERIOR NERVE-ROOT DECOMPRESSION, STABILIZATION, AND ARTHRODESIS [J].
FAREY, ID ;
MCAFEE, PC ;
DAVIS, RF ;
LONG, DM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (08) :1171-1177
[9]
GALLAGHER MR, 1993, NEUROSURGERY, V33, P1045
[10]
Reoperation in patients after anterior cervical plate stabilization in degenerative disease [J].
Geisler, FH ;
Caspar, W ;
Pitzen, T ;
Johnson, TA .
SPINE, 1998, 23 (08) :911-920