Micropreparative ligand fishing with a cuvette-based optical mirror resonance biosensor

被引:33
作者
Catimel, B [1 ]
Weinstock, J [1 ]
Nerrie, M [1 ]
Domagala, T [1 ]
Nice, EC [1 ]
机构
[1] Royal Melbourne Hosp, Melbourne Tumour Biol Branch, Ludwig Inst Canc Res, Parkville, Vic 3050, Australia
关键词
biosensors; ligand fishing; detection; LC; antigens; antibodies;
D O I
10.1016/S0021-9673(99)01098-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We have previously demonstrated the role of an optical biosensor (BIAcore 2000) as a specific detector to monitor chromatographic fractions during the purification and characterisation of ligands for orphan biomolecules. We have now extended this application to perform micropreparative ligand fishing directly on the sensor surface using an automated cuvette-based optical biosensor (Iasys Auto+) equipped with a high-capacity carboxymethyldextran surface (surface area 16 mm(2)). Using a F(ab)(2)' fragment of the A33 monoclonal antibody as bait, we have recovered microgram quantities of essentially homogeneous A33 ligand from the sensor surface in a form suitable for subsequent sensitive and specific down stream analysis (micropreparative HPLC, sodium dodecyl sulphate-polyacrylamide gel electrophoresis and Western blotting). The design of the cuvette-based system facilitates recovery of desorbed material from the constrained workspace in small volumes at high concentration. The use of on-surface detection allows the surface viability to be continuously monitored and permits direct quantitation of both bound and recovered material. (C) 2000 Elsevier Science BN. All rights reserved.
引用
收藏
页码:261 / 273
页数:13
相关论文
共 44 条
  • [1] Radioimmunotherapy of colorectal carcinoma xenografts in nude mice with yttrium-90 A33 IgG and tri-fab (TFM)
    Antoniw, P
    Farnsworth, APH
    Turner, A
    Haines, AMR
    Mountain, A
    Mackintosh, J
    Shochat, D
    Humm, J
    Welt, S
    Old, LJ
    Yarranton, GT
    King, DJ
    [J]. BRITISH JOURNAL OF CANCER, 1996, 74 (04) : 513 - 524
  • [2] Barendswaard EC, 1998, INT J ONCOL, V12, P45
  • [3] B61 IS A LIGAND FOR THE ECK RECEPTOR PROTEIN-TYROSINE KINASE
    BARTLEY, TD
    HUNT, RW
    WELCHER, AA
    BOYLE, WJ
    PARKER, VP
    LINDBERG, RA
    LU, HS
    COLOMBERO, AM
    ELLIOTT, RL
    GUTHRIE, BA
    HOLST, PL
    SKRINE, JD
    TOSO, RJ
    ZHANG, M
    FERNANDEZ, E
    TRAIL, G
    VARNUM, B
    YARDEN, Y
    HUNTER, T
    FOX, GM
    [J]. NATURE, 1994, 368 (6471) : 558 - 560
  • [4] Proteomics: quantitative and physical mapping of cellular proteins
    Blackstock, WP
    Weir, MP
    [J]. TRENDS IN BIOTECHNOLOGY, 1999, 17 (03) : 121 - 127
  • [5] OPTICAL PROBES AND TRANSDUCERS
    BRECHT, A
    GAUGLITZ, G
    [J]. BIOSENSORS & BIOELECTRONICS, 1995, 10 (9-10) : 923 - 936
  • [6] BUCKLE PE, 1993, BIOSENS BIOELECTRON, V8, P365
  • [7] Kinetic analysis of the interaction between the monoclonal antibody A33 and its colonic epithelial antigen by the use of an optical biosensor - A comparison of immobilisation strategies
    Catimel, B
    Nerrie, M
    Lee, FT
    Scott, AM
    Ritter, G
    Welt, S
    Old, LJ
    Burgess, AW
    Nice, EC
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1997, 776 (01) : 15 - 30
  • [8] Purification and characterization of a novel restricted antigen expressed by normal and transformed human colonic epithelium
    Catimel, B
    Ritter, G
    Welt, S
    Old, LJ
    Cohen, L
    Nerrie, MA
    White, SJ
    Heath, JK
    Demediuk, B
    Domagala, T
    Lee, FT
    Scott, AM
    Tu, GF
    Ji, H
    Moritz, RL
    Simpson, RJ
    Burgess, AW
    Nice, EC
    [J]. JOURNAL OF BIOLOGICAL CHEMISTRY, 1996, 271 (41) : 25664 - 25670
  • [9] THE RESONANT MIRROR - A NOVEL OPTICAL BIOSENSOR FOR DIRECT SENSING OF BIOMOLECULAR INTERACTIONS .1. PRINCIPLE OF OPERATION AND ASSOCIATED INSTRUMENTATION
    CUSH, R
    CRONIN, JM
    STEWART, WJ
    MAULE, CH
    MOLLOY, J
    GODDARD, NJ
    [J]. BIOSENSORS & BIOELECTRONICS, 1993, 8 (7-8) : 347 - 353
  • [10] DAVIES RJ, 1994, TECHNIQUES PROTEIN C, V5, P285