Serum levels of cobalt and chromium in a complex modular total hip arthroplasty system

被引:21
作者
Harding, I
Bonomo, A
Crawford, R
Psychoyios, V
Delves, T
Murray, D
McLardy-Smith, P
机构
[1] Southampton Gen Hosp, SAS Trace Element Unit, Southampton SO9 4XY, Hants, England
[2] Nuffield Orthopaed Ctr, Oxford, England
关键词
hip; arthroplasty; corrosion; periprosthetic fracture; metal ions;
D O I
10.1054/arth.2002.34539
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
There is concern that modularity in a total hip arthroplasty system increases serum cobalt and chromium ion levels. This study measures the serum cobalt and chromium levels in patients with an Oxford Universal Hip (Corin, Cirencester, United Kingdom), which has a modular sliding mechanism; patients with a similarly manufactured hip with no sliding mechanism; and a control group. Loosening was excluded clinically and radiologically. Arthroplasty patients had statistically higher levels of serum cobalt and chromium than controls, but there was no significant difference in levels between the implanted groups.
引用
收藏
页码:893 / 895
页数:3
相关论文
共 15 条
[1]
ALFAROADRIAN J, 1998, HIP INT, V8, P62
[2]
BLACK J, 1988, J BONE JOINT SURG BR, V70, P515
[3]
FRETTING CORROSION ACCELERATES CREVICE CORROSION OF MODULAR HIP TAPERS [J].
BROWN, SA ;
FLEMMING, CAC ;
KAWALEC, JS ;
PLACKO, HE ;
VASSAUX, C ;
MERRITT, K ;
PAYER, JH ;
KRAAY, MJ .
JOURNAL OF APPLIED BIOMATERIALS, 1995, 6 (01) :19-26
[4]
CONCENTRATION OF WEAR PRODUCTS IN HAIR, BLOOD, AND URINE AFTER TOTAL HIP REPLACEMENT [J].
COLEMAN, RF ;
HERRINGTON, J ;
SCALES, JT .
BMJ-BRITISH MEDICAL JOURNAL, 1973, 1 (5852) :527-529
[5]
CORROSION BETWEEN THE COMPONENTS OF MODULAR FEMORAL HIP PROSTHESES [J].
COLLIER, JP ;
SURPRENANT, VA ;
JENSEN, RE ;
MAYOR, MB ;
SURPRENANT, HP .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (04) :511-517
[6]
CRAWFORD RW, 1998, J BONE JOINT SURG S, V80, P55
[7]
IN-VIVO CORROSION OF MODULAR HIP-PROSTHESIS COMPONENTS IN MIXED AND SIMILAR METAL COMBINATIONS - THE EFFECT OF CREVICE, STRESS, MOTION, AND ALLOY COUPLING [J].
GILBERT, JL ;
BUCKLEY, CA ;
JACOBS, JJ .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (12) :1533-1544
[8]
THE INCIDENCE OF CANCER FOLLOWING TOTAL HIP-REPLACEMENT [J].
GILLESPIE, WJ ;
FRAMPTON, CMA ;
HENDERSON, RJ ;
RYAN, PM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (04) :539-542
[9]
Metal release in patients who have has a primary total hip arthroplasty - A prospective, controlled, longitudinal study [J].
Jacobs, JJ ;
Skipor, AK ;
Patteson, LM ;
Hallab, NJ ;
Paprosky, WG ;
Black, J ;
Galante, JO .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (10) :1447-1458
[10]
Systemic release of cobalt and chromium after uncemented total hip replacement [J].
Kreibich, DN ;
Moran, CG ;
Delves, HT ;
Owen, TD ;
Pinder, IM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (01) :18-21