A magnetically suspended and hydrostatically stabilized centrifugal blood pump

被引:15
作者
Hart, RM [1 ]
Filipenco, VG [1 ]
Kung, RTV [1 ]
机构
[1] CARRIER CORP,UNITED TECHNOL,SYRACUSE,NY
关键词
magnetic suspension; magnetic bearings; hydrostatic bearings; centrifugal blood pump; ventricular assist device;
D O I
10.1111/j.1525-1594.1996.tb04487.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A magnetically suspended centrifugal blood pump intended for application as a long-term implantable ventricular assist device has been built and tested. The rotor is freely suspended in the blood by magnetic and hydrostatic restoring forces, This design obviates the need for bearings and shaft seals, and eliminates the problems of reliability and thrombogenicity associated with them. The positional stability and hydrodynamic performance of the pump has been characterized in vitro at flows of up to 10 L/min at physiologic pressures. Radial position control is realized by an analog electronic feedback control system. The pressure distribution in the fluid surrounding the rotor provides dynamic control in the axial direction with no active feedback. Rotor excursion is less than 50 microns (mu) when the housing receives an impulse peaking at an acceleration of 40 g or upon sudden blockage of the flow. In vitro blood measurements indicate an acceptable level of hemolysis compared with that of a standard centrifugal pump.
引用
收藏
页码:591 / 596
页数:6
相关论文
共 9 条
[1]   RECENT STUDIES OF THE CENTRIFUGAL BLOOD PUMP WITH A MAGNETICALLY SUSPENDED IMPELLER [J].
AKAMATSU, T ;
TSUKIYA, T ;
NISHIMURA, K ;
PARK, CH ;
NAKAZEKI, T .
ARTIFICIAL ORGANS, 1995, 19 (07) :631-634
[2]   A FREE-FLOATING BODY AS THE ROTOR OF A CENTRIFUGAL BLOOD PUMP FOR LVAD OR TAH [J].
BRAMM, G ;
NOVAK, P ;
OLSEN, DB .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1982, 5 (03) :161-162
[3]   FREQUENCY OF SEAL DISRUPTION WITH THE SARNS CENTRIFUGAL PUMP IN POSTCARDIOTOMY CIRCULATORY ASSIST [J].
CURTIS, JJ ;
BOLEY, TM ;
WALLS, JT ;
DEMMY, TL ;
SCHMALTZ, RA .
ARTIFICIAL ORGANS, 1994, 18 (03) :235-237
[4]  
GOLDING LAR, 1979, ASSISTED CIRCULATION
[5]  
Massey B.S., 1989, MECH FLUIDS, Vsixth
[6]  
*PHILL SEM, 1994, DAT SHEETS FULL WAV
[7]  
SCHIMA H, 1993, ARTIF ORGANS, V17, P164
[8]   THE EFFECTS OF PRESSURE AND FLOW ON HEMOLYSIS CAUSED BY BIO-MEDICUS CENTRIFUGAL PUMPS AND ROLLER-PUMPS - GUIDELINES FOR CHOOSING A BLOOD PUMP [J].
TAMARI, Y ;
LEESENSIBA, K ;
LEONARD, EF ;
PARNELL, V ;
TORTOLANI, AJ .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1993, 106 (06) :997-1007
[9]  
1995, ARTIF ORGANS, V19, P565