Spatiotemporal correlation analyses:: a new procedure for standardisation of DC magnetocardiograms

被引:3
作者
Goernig, Matthias
Tute, Christian
Liehr, Mario
Lau, Stephan
Haueisen, Jens
Figulla, Hans R.
Leder, Uwe
机构
[1] Univ Jena, Dept Med 1, D-07747 Jena, Germany
[2] Univ Jena, Dept Neurol, Biomagnet Ctr, D-07747 Jena, Germany
[3] Univ Technol, Inst Biomed Engn & Informat, Ilmenau, Germany
来源
BIOMEDIZINISCHE TECHNIK | 2006年 / 51卷 / 04期
关键词
electrocardiography; magnetocardiography; myocardial infarction; repolarization; spatiotemporal analyses;
D O I
10.1515/BMT.2006.036
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
There is a lack of standard methods for the analysis of magnetocardiograms (MCGs). MCG signals have a shape similar to the ECG (P wave, QRS complex, T wave). High-quality multichannel recordings can indicate even slight disturbances of de- and repolarisation. The purpose of our study was to apply a new approach in the analysis of signal-averaged DC-MCGs. DC-MCGs (31-channel) were recorded in 182 subjects: 110 patients after myocardial infarction and 72 controls. Spatiotemporal correlation analysis of the QRS complex and T wave patterns throughout the entire heart cycle was used to analyse homogeneity of de- and repolarisation. These plots were compared to standard ECG analyses (electrical axis, Q wave, ST deviation, T polarity and shape). Spatiotemporal correlation analyses seem to be applicable in assessing the course of electrical repolarisation with respect to homogeneity. MCG provided all diagnostic information contained in common ECG recordings at high significance levels. The ECG patterns were included in 5/8 of our parameters for electrical axis, 6/8 for Q-wave, 7/8 for ST deviation and 5/8 for T-polarity based on two time series of correlation coefficients. We conclude that our spatiotemporal correlation approach provides a new tool for standardised analysis of cardiac mapping data such as MCG.
引用
收藏
页码:198 / 200
页数:3
相关论文
共 6 条
[1]   A MODULAR APPROACH TO MULTICHANNEL MAGNETOMETRY [J].
DOSSEL, O ;
DAVID, B ;
FUCHS, M ;
KRUGER, J ;
KULLMANN, WH ;
LUDEKE, KM .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1991, 12 :75-79
[2]   Clinical application of magnetocardiography [J].
Fenici, R ;
Brisinda, D ;
Meloni, AM .
EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2005, 5 (03) :291-313
[3]   QRS amplitude and shape variability in magnetocardiograms [J].
Huck, M ;
Haueisen, J ;
Hoenecke, O ;
Fritschi, T ;
Leder, U ;
Nowak, H .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (02) :234-242
[4]   Measurement and reproducibility of magnetocardiographic filtered atrial signal in patients with paroxysmal lone atrial fibrillation and in healthy subjects [J].
Koskinen, R ;
Lehto, M ;
Väänänen, H ;
Rantonen, J ;
Voipio-Pulkki, LM ;
Mäkijärvi, M ;
Lehtonen, L ;
Montonen, J ;
Toivonen, L .
JOURNAL OF ELECTROCARDIOLOGY, 2005, 38 (04) :330-336
[5]   Magnetocardiography predicts coronary artery disease in patients with acute chest pain [J].
Park, JW ;
Hill, PM ;
Chung, N ;
Hugenholtz, PG ;
Jung, F .
ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2005, 10 (03) :312-323
[6]   Active shielding to reduce low frequency disturbances in direct current near biomagnetic measurements [J].
Platzek, D ;
Nowak, H ;
Giessler, F ;
Röther, J ;
Eiselt, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (05) :2465-2470