Rapid on-chip genetic detection microfluidic platform for real world applications

被引:38
作者
Senapati, Satyajyoti [1 ]
Mahon, Andrew R. [2 ]
Gordon, Jason [3 ]
Nowak, Carsten [4 ,5 ]
Sengupta, Shramik [6 ]
Powell, Thomas H. Q. [2 ]
Feder, Jeffrey [2 ]
Lodge, David M. [2 ]
Chang, Hsueh-Chia [1 ]
机构
[1] Univ Notre Dame, Dept Chem & Biomol Engn, Notre Dame, IN 46556 USA
[2] Univ Notre Dame, Dept Biol Sci, Ctr Aquat Conservat, Notre Dame, IN 46556 USA
[3] Midwest Res Inst, Special Programs Div, Kansas City, MO 64110 USA
[4] Senckenberg Res Inst, Conservat Genet Grp, D-63571 Gelnhausen, Germany
[5] Res Stn Gelnhausen, Nat Hist Museum, D-63571 Gelnhausen, Germany
[6] Univ Missouri, Dept Biol Engn, Columbia, MO 65211 USA
关键词
biosensors; DNA; lab-on-a-chip; microfluidics; TOTAL ANALYSIS SYSTEMS; DNA HYBRIDIZATION; PLANKTON SAMPLES; DISCRIMINATION; LARVAE; BEADS;
D O I
10.1063/1.3127142
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The development of genetic detection protocols for field applications is an important aspect of modern medical diagnostic technology and environmental monitoring. In this paper, we report a rapid, portable, and inexpensive DNA hybridization technique using a bead-based microfluidic platform that functions by passing fluorescently labeled target DNA through a chamber packed with functionalized beads within a microfluidic channel. DNA hybridization is then assessed using a digital camera attached to a Clare Chemical DR-45M dark reader non-UV transilluminator that uses visible light as an excitation source and a blue and amber filter to reveal fluorescence. This microfluidic approach significantly enhances hybridization by reducing the diffusion time between target DNA and the silica surface. The use of probe-functionalized beads as solid support also enhances the sensitivity and limit of detection due to a larger surface area per unit volume. This platform could be adapted for use in medical applications and environmental monitoring, including the detection of harmful organisms in the ballast water of ships.
引用
收藏
页数:7
相关论文
共 22 条
  • [1] DNA hybridization and discrimination of single-nucleotide mismatches using chip-based microbead arrays
    Ali, MF
    Kirby, R
    Goodey, AP
    Rodriguez, MD
    Ellington, AD
    Neikirk, DP
    McDevitt, JT
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (18) : 4732 - 4739
  • [2] Advances in nucleic acid-based diagnostics of bacterial infections
    Barken, Kim B.
    Haagensen, Janus A. J.
    Tolker-Nielsen, Tim
    [J]. CLINICA CHIMICA ACTA, 2007, 384 (1-2) : 1 - 11
  • [3] Gene expression analysis by massively parallel signature sequencing (MPSS) on microbead arrays
    Brenner, S
    Johnson, M
    Bridgham, J
    Golda, G
    Lloyd, DH
    Johnson, D
    Luo, SJ
    McCurdy, S
    Foy, M
    Ewan, M
    Roth, R
    George, D
    Eletr, S
    Albrecht, G
    Vermaas, E
    Williams, SR
    Moon, K
    Burcham, T
    Pallas, M
    DuBridge, RB
    Kirchner, J
    Fearon, K
    Mao, J
    Corcoran, K
    [J]. NATURE BIOTECHNOLOGY, 2000, 18 (06) : 630 - 634
  • [4] Development and evaluation of a PCR-based test for detection of Asterias (Echinodermata: Asteroidea) larvae in Australian plankton samples from ballast water
    Deagle, BE
    Bax, N
    Hewitt, CL
    Patil, JG
    [J]. MARINE AND FRESHWATER RESEARCH, 2003, 54 (06) : 709 - 719
  • [5] Dynamic DNA hybridization on a chip using paramagnetic beads
    Fan, ZH
    Mangru, S
    Granzow, R
    Heaney, P
    Ho, W
    Dong, QP
    Kumar, R
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (21) : 4851 - 4859
  • [6] Electrochemical microfluidic biosensor for the detection of nucleic acid sequences
    Goral, VN
    Zaytseva, NV
    Baeumner, AJ
    [J]. LAB ON A CHIP, 2006, 6 (03) : 414 - 421
  • [7] Hybridization reaction kinetics of DNA probes on beads arrayed in a capillary enhanced by turbulent flow
    Kohara, Y
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (13) : 3079 - 3085
  • [8] Hybridization enhancement using cavitation microstreaming
    Liu, RH
    Lenigk, R
    Druyor-Sanchez, RL
    Yang, JN
    Grodzinski, P
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (08) : 1911 - 1917
  • [9] Capture of DNA in microfluidic channel using magnetic beads: Increasing capture efficiency with integrated microfluidic mixer
    Lund-Olesen, T.
    Dufva, M.
    Hansen, M. F.
    [J]. JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2007, 311 (01) : 396 - 400
  • [10] Beads arraying and beads used in DNA chips
    Marquette, CA
    Blum, LJ
    [J]. IMMOBILISATION OF DNA ON CHIPS II, 2005, 261 : 113 - 129