Trends in Total Hip Arthroplasty Implant Utilization in the United States

被引:142
作者
Lehil, Mandeep S. [1 ]
Bozic, Kevin J. [2 ,3 ]
机构
[1] Univ Calif San Francisco, Sch Med, San Francisco, CA 94143 USA
[2] Univ Calif San Francisco, Dept Orthopaed Surg, San Francisco, CA 94143 USA
[3] Univ Calif San Francisco, Philip R Lee Inst Hlth Policy Studies, San Francisco, CA 94143 USA
关键词
THA; implant; trend; total hip arthroplasty; utilization; ACETABULAR COMPONENTS; WEAR; HEADS; REVISION; OUTCOMES; BEARING;
D O I
10.1016/j.arth.2014.05.017
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Total hip arthroplasty (THA) implant usage has evolved as experience has been gained with newer implant designs. The purpose of this study was to characterize trends in THA implant usage between 2001 and 2012. The Orthopedic Research Network, which includes 174 hospitals and similar to 105,000 THA, was used to evaluate trends in fixation, bearings, acetabular cup and liner, and femoral head usage. In 2012, 93% of THAs were cementless; 56% of THA bearings were metal-HXLPE; and 35% were ceramic-HXLPE. 99% of acetabular cups were modular. 61% of femoral heads were metal, 39% were ceramic, 51% were 36 mm, and 28% were 32 mm. THA implant usage trends favor cementless fixation, metal-on-polyethylene or ceramic-on-polyethylene bearings, modular acetabular cups, and large diameter femoral heads. (c) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:1915 / 1918
页数:4
相关论文
共 32 条
[1]
Retrieval analysis of three generations of Biolox® femoral heads: Spectroscopic and SEM characterisation [J].
Affatato, S. ;
Modena, E. ;
Toni, A. ;
Taddei, P. .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2012, 13 :118-128
[2]
Wear of 36-mm BIOLOX® delta ceramic-on-ceramic bearing in total hip replacements under edge loading conditions [J].
Al-Hajjar, Mazen ;
Fisher, John ;
Tipper, Joanne L. ;
Williams, Sophie ;
Jennings, Louise M. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (H5) :535-542
[3]
Comparison of Surgical Outcomes and Implant Wear Between Ceramic-Ceramic and Ceramic-Polyethylene Articulations in Total Hip Arthroplasty [J].
Amanatullah, Derek F. ;
Landa, Joshua ;
Strauss, Eric J. ;
Garino, Jonathan P. ;
Kim, Sunny H. ;
Di Cesare, Paul E. .
JOURNAL OF ARTHROPLASTY, 2011, 26 (06) :72-77
[4]
Current Practice Patterns in Primary Hip and Knee Arthroplasty Among Members of the American Association of Hip and Knee Surgeons [J].
Berry, Daniel J. ;
Bozic, Kevin J. .
JOURNAL OF ARTHROPLASTY, 2010, 25 (06) :2-4
[5]
High Prevalence of Pseudotumors in Patients with a Birmingham Hip Resurfacing Prosthesis A Prospective Cohort Study of One Hundred and Twenty-nine Patients [J].
Bisschop, R. ;
Boomsma, M. F. ;
Van Raay, J. J. A. M. ;
Tiebosch, A. T. M. G. ;
Maas, M. ;
Gerritsma, C. L. E. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2013, 95A (17) :1554-1560
[6]
Modern Metal-on-Metal Hip Implants [J].
Bozic, Kevin J. ;
Browne, James ;
Dangles, Chris J. ;
Manner, Paul A. ;
Yates, Adolph J., Jr. ;
Weber, Kristy L. ;
Boyer, Kevin M. ;
Zemaitis, Paul ;
Woznica, Anne ;
Turkelson, Charles M. ;
Wies, Janet L. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2012, 20 (06) :402-406
[7]
Centers for Disease Control Prevention, 2013, INP SURG
[8]
Corten Kristoff, 2009, Orthopedics, V32, DOI 10.3928/01477447-20090728-10
[9]
Elkins JM, 2013, CLIN ORTHOP RELAT R, V472, P529
[10]
Total hip arthroplasty with a cemented, polished, collared femoral stem and a cementless acetabular component - A follow-up study at a minimum of ten years [J].
Firestone, Daniel E. ;
Callaghan, John J. ;
Liu, Steve S. ;
Goetz, Devon D. ;
Sullivan, Patrick M. ;
Vittetoe, David A. ;
Johnston, Richard C. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (01) :126-132