No significant translocation of inhaled 35-nm carbon particles to the circulation in humans

被引:87
作者
Wiebert, Pernilla [1 ]
Sanchez-Crespo, Alejandro
Falk, Rolf
Philipson, Klas
Lundin, Anders
Larsson, Stig
Moeller, Winfried
Kreyling, Wolfgang G.
Svartengren, Magnus
机构
[1] Karolinska Hosp, Dept Environm & Occupat Hlth, Stockholm Cty Council, SE-17176 Stockholm, Sweden
[2] Karolinska Inst, Dept Publ Hlth Sci, Stockholm, Sweden
[3] Karolinska Hosp, Dept Nucl Med, SE-17176 Stockholm, Sweden
[4] Swedish Radiat Protect Author, Stockholm, Sweden
[5] Karolinska Inst, Inst Environm Med, Stockholm, Sweden
[6] GSF, Natl Res Ctr, Inst Inhalat Biol, Neuherberg, Germany
关键词
D O I
10.1080/08958370600748455
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
Human pulmonary retention of 35 nm 99m Tc-labeled carbonaceous particles, produced with a modified Technegas generator, was followed for 24 h using a gamma camera imaging technique. Nine healthy subjects and four asthmatics inhaled the test particles. Particle labeling stability was tested in vitro during 48 h. We also measured in vivo leaching in blood and in urine for 24 h. One additional subject was exposed to particles with unstable labeling. There were no significant differences between healthy and asthmatic subjects in any of the parameters studied. Particle retention after 24 h was 102% (SD +/- 4.7). Cumulative in vitro leaching of 99m Tc activity from the particles was 1.7% (1.1) after 24 h. In blood samples, 80 min after exposure, 1.1% ( 0.4) of initially deposited activity was detected and 91% of the activity was not bound to particles. In urine sampled during the first 24 h after exposure, 3.6% ( 0.9) of lung deposited activity was detected. Lung retention was 30% after 1 h in the subject exposed to the leaching aerosol (n = 1). Thirty-one percent of the deposited activity was detected in the blood after 80 min and 80% was not bound to particles. Fifty percent of the activity was excreted with urine within 24 h. On gamma camera images the activity visibly translocated from lungs to thyroid and gastrointestinal tract. In conclusion, over a 24-h period there was no significant translocation of inhaled 35-nm particles to the systemic circulation.
引用
收藏
页码:741 / 747
页数:7
相关论文
共 23 条
[1]  
Areskoug H, 2000, SCAND J WORK ENV HEA, V26, P1
[2]   Acute effects of particulate air pollution on respiratory admissions - Results from APHEA 2 project [J].
Atkinson, RW ;
Anderson, HR ;
Sunyer, J ;
Ayres, J ;
Baccini, M ;
Vonk, JM ;
Boumghar, A ;
Forastiere, F ;
Forsberg, B ;
Touloumi, G ;
Schwartz, J ;
Katsouyanni, K .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 164 (10) :1860-1866
[3]   DISTRIBUTION AND EXCRETION OF TECHNETIUM IN HUMANS [J].
BEASLEY, TM ;
PALMER, HE ;
NELP, WB .
HEALTH PHYSICS, 1966, 12 (10) :1425-+
[4]   Ultrafine particle deposition and clearance in the healthy and obstructed lung [J].
Brown, JS ;
Zeman, KL ;
Bennett, WD .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2002, 166 (09) :1240-1247
[5]   AN ASSOCIATION BETWEEN AIR-POLLUTION AND MORTALITY IN 6 UNITED-STATES CITIES [J].
DOCKERY, DW ;
POPE, CA ;
XU, XP ;
SPENGLER, JD ;
WARE, JH ;
FAY, ME ;
FERRIS, BG ;
SPEIZER, FE .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 329 (24) :1753-1759
[6]   Ultrafine particles [J].
Donaldson, K ;
Stone, V ;
Clouter, A ;
Renwick, L ;
MacNee, W .
OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2001, 58 (03) :211-+
[7]   TECHNETIUM ABSORPTION AND TURNOVER IN MONOGASTRIC AND POLYGASTRIC ANIMALS [J].
GERBER, GB ;
VANHEES, M ;
GARTEN, CT ;
VANDECASTEELE, CM ;
VANKERKOM, J ;
VANBRUWAENE, R ;
KIRCHMANN, R ;
COLARD, J ;
COGNEAU, M .
HEALTH PHYSICS, 1989, 57 (02) :315-319
[8]   Cause-specific mortality and the extended effects of particulate pollution and temperature exposure [J].
Goodman, PG ;
Dockery, DW ;
Clancy, L .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2004, 112 (02) :179-185
[9]   INHALATION OF PERTECHNEGAS - SIMILAR CLEARANCE FROM THE LUNGS TO THAT OF INHALED PERTECHNETATE AEROSOL [J].
ISAWA, T ;
TESHIMA, T ;
ANAZAWA, Y ;
MIKI, M ;
MAHMUD, AM .
NUCLEAR MEDICINE COMMUNICATIONS, 1995, 16 (09) :741-746
[10]   Comparative measurement of lung deposition of inhaled fine particles in normal subjects and patients with obstructive airway disease [J].
Kim, CS ;
Kang, TC .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1997, 155 (03) :899-905