Helical (spiral) CT of the upper airway with three-dimensional imaging: Technique and clinical assessment

被引:78
作者
Zeiberg, AS
Silverman, PM
Sessions, RB
Troost, TR
Davros, WJ
Zeman, RK
机构
[1] GEORGETOWN UNIV HOSP,DEPT OTOLARYNGOL,WASHINGTON,DC 20007
[2] CLEVELAND CLIN FDN,DEPT RADIOL,CLEVELAND,OH 44195
关键词
D O I
10.2214/ajr.166.2.8553933
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE, The purpose of this study was to evaluate the application of helical CT-generated three-dimensional images of the upper airway. MATERIALS AND METHODS, Thirty patients, 10 healthy and 20 with upper-airway disease, were studied with helical CT (5-mm collimation). Overlapping images at 2-mm intervals were retrospectively generated, In the group of healthy patients, two radiologists independently compared overlapping with nonoverlapping images, ranked confidence in identifying small airway structures on a scale of 1-5, and tabulated the number of images demonstrating these structures. In the 20 patients with disease, three-dimensional (3D) surface models were rendered on an independent workstation and were reviewed by two radiologists and one otolaryngologist for image quality, appreciation of lesion morphology, and ability to judge lesion extent, using a similar scale, A phantom was used to optimize parameters for the 3D reconstructions. RESULTS, Viewing of the retrospectively generated overlapping images increased by 122% the number of images in which laryngeal and hypopharyngeal structures could be identified (p < .01), Image confidence scores for the radiologists averaged 3.3 for nonoverlapping and 4.0 for overlapping (p < .05). Radiologists and otolaryngologist rated the quality of the 3D images equally, The otolaryngologist's assessment of the value of the models for understanding the lesion morphology was 3.5 compared with the radiologists assessment of 2.5; and for judging the lesion extent, the otolaryngologist's assessment was 3.8 compared with 2.7 for the radiologists, a statistical significance of p < .01. CONCLUSION. Helical CT with the application of overlapping images and 3D reconstructions significantly assists the understanding of upper-airway disease.
引用
收藏
页码:293 / 299
页数:7
相关论文
共 14 条
[1]   SPIRAL CT OF THE THORAX [J].
COSTELLO, P .
SEMINARS IN ULTRASOUND CT AND MRI, 1994, 15 (02) :90-106
[2]  
CURTIN HD, 1989, RADIOLOGY, V173, P1
[3]  
HEIKEN JP, 1993, RADIOLOGY, V189, P649
[4]   TECHNICAL FOUNDATIONS OF SPIRAL CT [J].
KALENDER, WA .
SEMINARS IN ULTRASOUND CT AND MRI, 1994, 15 (02) :81-89
[5]   A COMPARISON OF CONVENTIONAL AND SPIRAL CT - AN EXPERIMENTAL-STUDY ON THE DETECTION OF SPHERICAL LESIONS [J].
KALENDER, WA ;
POLACIN, A ;
SUSS, C .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (02) :167-176
[6]   PLEURAL INVASION BY PERIPHERAL BRONCHOGENIC-CARCINOMA - ASSESSMENT WITH 3-DIMENSIONAL HELICAL CT [J].
KURIYAMA, K ;
TATEISHI, R ;
KUMATANI, T ;
KODAMA, K ;
DOI, O ;
HOSOMI, N ;
SAWAI, Y ;
INOUE, E ;
KADOTA, T ;
NARUMI, Y ;
FUJITA, M ;
KURODA, C .
RADIOLOGY, 1994, 191 (02) :365-369
[7]   PULMONARY NODULES - DETECTION WITH THICK-SECTION SPIRAL CT VERSUS CONVENTIONAL CT [J].
REMYJARDIN, M ;
REMY, J ;
GIRAUD, F ;
MARQUETTE, CH .
RADIOLOGY, 1993, 187 (02) :513-520
[8]   HELICAL CT - PRACTICAL CONSIDERATIONS AND POTENTIAL PITFALLS [J].
SILVERMAN, PM ;
COOPER, CJ ;
WELTMAN, DI ;
ZEMAN, RK .
RADIOGRAPHICS, 1995, 15 (01) :25-36
[9]   3-DIMENSIONAL IMAGING OF THE HYPOPHARYNX AND LARYNX BY MEANS OF HELICAL (SPIRAL) COMPUTED-TOMOGRAPHY - COMPARISON OF RADIOLOGICAL AND OTOLARYNGOLOGICAL EVALUATION [J].
SILVERMAN, PM ;
ZEIBERG, AS ;
SESSIONS, RB ;
TROOST, TR ;
ZEMAN, RK .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1995, 104 (06) :425-431
[10]   CARCINOMA OF THE LARYNX AND HYPOPHARYNX - COMPUTED TOMOGRAPHIC-HISTOPATHOLOGIC CORRELATIONS [J].
SILVERMAN, PM ;
BOSSEN, EH ;
FISHER, SR ;
COLE, TB ;
KOROBKIN, M ;
HALVORSEN, RA .
RADIOLOGY, 1984, 151 (03) :697-702