Effect of femoral component position on biomechanical outcomes of unicompartmental knee arthroplasty

被引:32
作者
Kang, Kyoung-Tak [1 ]
Son, Juhyun [1 ]
Koh, Yong-Gon [2 ]
Kwon, Oh-Ryong [2 ]
Kwon, Sae Kwang [2 ]
Lee, Yong Jun [3 ]
Park, Kwan Kyu [3 ]
机构
[1] Yonsei Univ, Dept Mech Engn, Seoul, South Korea
[2] Yonsei Sarang Hosp, Joint Reconstruct Ctr, Dept Orthopaed Surg, Seoul, South Korea
[3] Yonsei Univ, Dept Orthoped Surg, Coll Med, 50-1 Yonsei Ro, Seoul 03722, South Korea
关键词
Contact stress; Finite element analysis; Malalignment; Unicompartmental knee arthroplasty; FINITE-ELEMENT-ANALYSIS; ANTERIOR CRUCIATE LIGAMENT; MOBILE-BEARING; IN-VIVO; UNICONDYLAR ARTHROPLASTY; REPLACEMENT; JOINT; INCLINATION; ALIGNMENT; MODEL;
D O I
10.1016/j.knee.2018.03.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Background: The positions of unicompartmental femoral components do not always follow the neutral center of the medial distal femoral condyle. The biomechanical effect of the center of the distal femoral condyle has not yet been evaluated, and the optimal femoral position in unicompartmental knee arthroplasty (UKA) is yet to be biomechanically justified. The purpose of this study was to evaluate, using finite element analysis, the effect of the center of the distal femoral component on the biomechanical outcomes of UKA with respect to the contact stresses in the polyethylene (PE) insert and articular cartilage. Methods: Five models in which the centers of the distal femoral components were translated by three millimeters and five millimeters to the medial and lateral sides, respectively, from the neutral position were modeled and analyzed in a gait loading condition. Results: The contact stresses on the PE insert increased as the center of the femoral component translated to the lateral side and, in contrast, the contact stresses decreased as it translated to the medial side. For the articular cartilage the contact stresses increased and decreased as the center of the femoral component translated to the medial and lateral sides. Conclusion: This study implied that the best position for the femoral component in UKA could be the center of the distal femoral condyle. Femoral component position could be one of the sensitive factors that influenced the contact stresses on the PE insert and articular cartilage, and the postoperative significance of the femoral component position in UKA. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:491 / 498
页数:8
相关论文
共 56 条
[31]
LAURENCIN CT, 1991, CLIN ORTHOP RELAT R, P151
[32]
Does 3-Dimensional In Vivo Component Rotation Affect Clinical Outcomes in Unicompartmental Knee Arthroplasty? [J].
Liow, Ming Han Lincoln ;
Tsai, Tsung-Yuan ;
Dimitriou, Dimitris ;
Li, Guoan ;
Kwon, Young-Min .
JOURNAL OF ARTHROPLASTY, 2016, 31 (10) :2167-2172
[33]
Is Recovery Faster for Mobile-bearing Unicompartmental than Total Knee Arthroplasty? [J].
Lombardi, Adolph V., Jr. ;
Berend, Keith R. ;
Walter, Christopher A. ;
Aziz-Jacobo, Jorge ;
Cheney, Nicholas A. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (06) :1450-1457
[34]
Deviation between navigated and final 3-dimensional implant position in mini-invasive unicompartmental knee arthroplasty A pilot study in 13 patients [J].
Martinez-Carranza, Nicolas ;
Weidenhielm, Lars ;
Crafoord, Joakim ;
Hedstrom, Margareta .
ACTA ORTHOPAEDICA, 2012, 83 (06) :625-628
[35]
McAuley JP, 2001, CLIN ORTHOP RELAT R, P279
[36]
Biomechanics of the knee joint in flexion under various quadriceps forces [J].
Mesfar, W ;
Shirazi-Adl, A .
KNEE, 2005, 12 (06) :424-434
[37]
Effects of radial tears and partial meniscectomy of lateral meniscus on the knee joint mechanics during the stance phase of the gait cycleA 3D finite element study [J].
Mononen, Mika E. ;
Jurvelin, Jukka S. ;
Korhonen, Rami K. .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2013, 31 (08) :1208-1217
[38]
Unicompartmental or total knee replacement THE 15-YEAR RESULTS OF A PROSPECTIVE RANDOMISED CONTROLLED TRIAL [J].
Newman, J. ;
Pydisetty, R. V. ;
Ackroyd, C. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (01) :52-57
[39]
The Repicci II® Unicondylar Knee Arthroplasty 9-year Survivorship and Function [J].
O'Donnell, Turlough ;
Neil, Michael J. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (11) :3094-3102
[40]
Park KK, 2017, ISTA 2017