Validity of apparent diffusion coefficient hyperpolarized 3He-MRI using MSCT and pulmonary function tests as references

被引:45
作者
Diaz, Sandra [1 ]
Casselbrant, Ingrid [2 ]
Piitulainen, Eeva [2 ]
Magnusson, Peter [3 ]
Peterson, Barry [4 ]
Wollmer, Per [5 ]
Leander, Peter [1 ]
Ekberg, Olle [1 ]
Akeson, Per [1 ,3 ]
机构
[1] Malmo Univ Hosp, Dept Radiol, SE-20502 Malmo, Sweden
[2] Malmo Univ Hosp, Dept Resp Med, SE-20502 Malmo, Sweden
[3] Univ Copenhagen, Hvidovre Hosp, DRCMR, DK-2650 Hvidovre, Denmark
[4] Pfizer, New London, CT USA
[5] Dept Clin Physiol, SE-20502 Malmo, Sweden
关键词
Apparent diffusion coefficient; Hyperpolarized He-3; Magnetic resonance imaging; Multislice computed tomography; Pulmonary function test; Emphysema; COMPUTED-TOMOGRAPHY; EMPHYSEMATOUS CHANGES; LUNG DENSITY; CT; MRI; QUANTIFICATION; DENSITOMETRY; MORPHOMETRY; DEFICIENCY; SMOKERS;
D O I
10.1016/j.ejrad.2008.04.013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Purpose: To compare apparent diffusion coefficient (ADC) measurements from hyperpolarized (HP) helium (He-3)-magnetic resonance imaging (MRI) with quantitative data from multislice Computed Tomography (CT) (MSCT) of the whole lungs and pulmonary function tests (PFT). Materials and methods: Twenty-seven subjects, 22 with established emphysema and 5 with preclinical emphysema defined by PFT criteria, were examined with Hp He-3-MRI and MSCT. Mean age was 55 (+/- 12) years, 18 female and 9 male. Mean ADC from He-3-MRI was compared with emphysema index (EI), 15th percentile and mean lung density (MLD) values from MSCT. Both mean ADC and MSCT data were compared to PFT, especially percent of predicted diffusing capacity of carbon monoxide (%predicted DLCO), using Pearson's correlation test. Results: Mean ADC and standard deviation values were 0.392 +/- 0.119 cm(2)/s for the established emphysema group and 0.216 +/- 0.046 for the pre-clinical emphysema group. MSCT values for the established emphysema group and pre-clinical emphysema group were: EI (%) 11 +/- 12 and 0.4 +/- 0.6, respectively; 15th percentile (Hounsfield Units (HU)), -956 +/- 25 and -933 +/- 13, respectively and MLD (HU) -877 +/- 20 and -863 +/- 15, respectively. Correlations between mean ADC and El and 15th percentile were both r=0.90 and for MLD r=0.59. There was higher correlation between mean ADC and %predicted DLCO (r=0.90) than between El and %predicted DLCO (r=0.76). Conclusion: Hp He-3-MRI correlates well with density measurements from MSCT and agrees better than MSCT with %predicted DLCO which is the PFT most related to emphysema. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:257 / 263
页数:7
相关论文
共 23 条
[1]
PERIPHERAL AIRSPACE DIMENSIONS IN PATIENTS WITH COPD [J].
BEINERT, T ;
BRAND, P ;
BEHR, J ;
VOGELMEIER, C ;
HEYDER, J .
CHEST, 1995, 108 (04) :998-1003
[2]
Hyperpolarized 3He apparent diffusion coefficient MRI of the lung:: Reproducibility and volume dependency in healthy volunteers and patients with emphysema [J].
Diaz, Sandra ;
Casselbrant, Ingrid ;
Piitulainen, Eeva ;
Pettersson, Goran ;
Magnusson, Peter ;
Peterson, Barry ;
Wollmer, Per ;
Leander, Peter ;
Ekberg, Olle ;
Akeson, Per .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (04) :763-770
[3]
Dirksen A, 1997, ACTA RADIOL, V38, P826
[4]
Early emphysematous changes in asymptomatic smokers:: Detection with 3He MR imaging [J].
Fain, Sean B. ;
Panth, Shilpa R. ;
Evans, Michael D. ;
Wentland, Andrew L. ;
Holmes, James H. ;
Korosec, Frank R. ;
O'Brien, Matthew J. ;
Fountaine, Harvey ;
Grist, Thomas M. .
RADIOLOGY, 2006, 239 (03) :875-883
[5]
COMPARISON OF COMPUTED DENSITY AND MACROSCOPIC MORPHOMETRY IN PULMONARY-EMPHYSEMA [J].
GEVENOIS, PA ;
DEMAERTELAER, V ;
DEVUYST, P ;
ZANEN, J ;
YERNAULT, JC .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1995, 152 (02) :653-657
[6]
CT MEASUREMENTS OF LUNG DENSITY IN LIFE CAN QUANTITATE DISTAL AIRSPACE ENLARGEMENT - AN ESSENTIAL DEFINING FEATURE OF HUMAN EMPHYSEMA [J].
GOULD, GA ;
MACNEE, W ;
MCLEAN, A ;
WARREN, PM ;
REDPATH, A ;
BEST, JJK ;
LAMB, D ;
FLENLEY, DC .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1988, 137 (02) :380-392
[7]
GOULD GA, 1991, EUR RESPIR J, V4, P141
[8]
POLARIZATION OF THE NUCLEAR SPINS OF NOBLE-GAS ATOMS BY SPIN EXCHANGE WITH OPTICALLY PUMPED ALKALI-METAL ATOMS [J].
HAPPER, W ;
MIRON, E ;
SCHAEFER, S ;
SCHREIBER, D ;
VANWIJNGAARDEN, WA ;
ZENG, X .
PHYSICAL REVIEW A, 1984, 29 (06) :3092-3110
[9]
Assessment of lung volumes using helical CT at inspiration and expiration: Comparison with pulmonary function tests [J].
Kauczor, HU ;
Heussel, CP ;
Fischer, B ;
Klamm, R ;
Mildenberger, P ;
Thelen, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (04) :1091-1095
[10]
Functional evaluation of emphysema using diffusion-weighted 3Helium-magnetic resonance imaging, high-resolution computed tomography, and lung function tests [J].
Ley, S ;
Zaporozhan, J ;
Morbach, A ;
Eberle, B ;
Gast, KK ;
Heussel, CP ;
Biedermann, A ;
Mayer, E ;
Schmiedeskamp, J ;
Stepniak, A ;
Schreiber, WG ;
Kauczor, HU .
INVESTIGATIVE RADIOLOGY, 2004, 39 (07) :427-434