Ion implantation by plasma immersion: interest, limitations and perspectives

被引:34
作者
Le Coeur, F [1 ]
Pelletier, J [1 ]
Arnal, Y [1 ]
Lacoste, A [1 ]
机构
[1] CNRS, UMR C5517, Electrostat & Mat Dielect Lab, F-38042 Grenoble 9, France
关键词
high voltage pulse; ion implantation; materials processing; plasma immersion; plasma sheath; pulse generator;
D O I
10.1016/S0257-8972(99)00554-X
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Plasma-based ion implantation (PBII) is a recent method to implant ions into materials for modifying surface properties. Negative high voltage pulses are applied to the substrate to extract ions from the plasma and accelerate them directly onto the substrate surface. The main advantages of PBII over ion beam implantation are its simplicity for processing large surfaces or three-dimensional objects and the possibility of preparing surfaces in situ prior to the implantation process. The two general specifications required for PBII are low pressure, large size plasmas and high voltage-high current pulse generators. Multipolar discharges excited by distributed electron cyclotron resonance, which can operate with reactive gases and can be easily scaled up, are thus well adapted to the PBII process. In order to produce the high voltage-high current pulses with rise and fall times of the order of the inverse ion plasma frequency necessary for PBII processing, generators using pulse transformers, where the voltage at the primary is provided by transistor switches and where the energy is stored at a low voltage level, have been developed. Then, before discussing the various limitations of the process, PBII in plasmas is illustrated through few selected examples. (C) 2000 Published by Elsevier Science S.A. All rights reserved.
引用
收藏
页码:71 / 78
页数:8
相关论文
共 26 条
[1]   A MONTE-CARLO COMPUTER-PROGRAM FOR THE TRANSPORT OF ENERGETIC IONS IN AMORPHOUS TARGETS [J].
BIERSACK, JP ;
HAGGMARK, LG .
NUCLEAR INSTRUMENTS & METHODS, 1980, 174 (1-2) :257-269
[2]   A 100 kV 10 a high-voltage pulse generator for plasma immersion ion implantation [J].
Brutscher, J .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (07) :2621-2625
[4]  
CONRAD JR, 1986, B AM PHYS SOC, V31, P1479
[5]   PRIMARY ELECTRON-DRIFT IN A VOLUME HYBRID MULTICUSP H- ION-SOURCE [J].
COURTEILLE, C ;
BRUNETEAU, J ;
VALCKX, FPG ;
SLEDZIEWSKI, Z ;
BACAL, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (11) :3265-3269
[6]   Influence of Multi-step Cumulative Deformation on Static Recrystallization of Steel 26Cr2Ni4MoV [J].
Ni, L. Y. ;
Kang, P. C. ;
Yu, S. Q. ;
Liu, Z. B. .
ADVANCED MATERIALS SCIENCE AND TECHNOLOGY, PTS 1-2, 2011, 181-182 :78-+
[7]   PRIMARY ELECTRON TRAJECTORIES IN A MULTIPOLAR DISCHARGE [J].
GAUTHEREAU, C ;
MATTHIEUSSENT, G .
JOURNAL DE PHYSIQUE, 1984, 45 (07) :1113-1123
[8]   ION-IMPLANTATION AND SURFACE MODIFICATION IN TRIBOLOGY [J].
HARTLEY, NEW .
WEAR, 1975, 34 (03) :427-438
[9]   Influence of the multipolar magnetic field configuration on the density of distributed electron cyclotron resonance plasmas [J].
Lagarde, T ;
Pelletier, J ;
Arnal, Y .
PLASMA SOURCES SCIENCE & TECHNOLOGY, 1997, 6 (01) :53-60
[10]   Influence of the applied field frequency on the characteristics of Ar and SF6 diffusion plasmas sustained at electron cyclotron resonance above multipolar magnetic field structures [J].
Lagarde, T ;
Arnal, Y ;
Pelletier, J .
PLASMA SOURCES SCIENCE & TECHNOLOGY, 1997, 6 (03) :386-393