In vivo study of approximal caries depth on storage phosphor plate images compared with dental x-ray film

被引:20
作者
Versteeg, KH
Sanderink, GCH
Velders, XL
vanGinkel, FC
vanderStelt, PF
机构
[1] Department of Oral Radiology, ACTA, Acad. Ctr. for Dentistry Amsterdam, Amsterdam
[2] Netherlands Inst. for Dent. Sciences, Acad. Ctr. for Dentistry Amsterdam, Amsterdam
[3] Acad. Center for Dentistry Amsterdam, Department of Oral Radiology, 1066 EA Amsterdam
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS | 1997年 / 84卷 / 02期
关键词
D O I
10.1016/S1079-2104(97)90071-8
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this in vivo study was to compare approximal caries depth on storage phosphor plate images to conventional film, A Soredex Digora imaging plate was placed in a film bite-wing positioner behind a Kodak Ektaspeed Plus film package without lead foil. The effect of scattered radiation on film without lead foil with a storage phosphor plate at the back was studied in a separate in vitro experiment, Compared with film protected by lead foil, the film showed higher density, but comparable contrast, For the in vivo study, clinical bite-wing exposures were made with the setup described above, with exposure settings for Ektaspeed Plus film. A four-point scale was chosen for approximal caries depth: 0 = no caries; 1 = caries in enamel: ? = caries reaching dentino-enamel junction; 3 = caries into dentin, The bite-wing film images were shown to a panel of lour experts. Sixty surfaces were selected for observer performance, based on identical scorings of the experts consensus classification. Next, six dentists evaluated both film and storage phosphor plate images with the same four point scale. Analysis of variance revealed a significant observer and image modality effect without an interaction effect. In conclusion, caries depth on storage phosphor plate images was underestimated compared with film-based images.
引用
收藏
页码:210 / 213
页数:4
相关论文
共 21 条
[1]   OBJECTIVE AND SUBJECTIVE EVALUATIONS OF KODAK EKTASPEED-PLUS DENTAL-X-RAY FILM [J].
CONOVER, GL ;
HILDEBOLT, CF ;
ANTHONY, D .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1995, 79 (02) :246-250
[2]  
CURRY TS, 1990, CHRISTENSENS PHYSICS
[3]   CONCURRENT VALIDITY OF AN EPIDEMIOLOGICAL DIAGNOSTIC SYSTEM FOR CARIES WITH HISTOLOGICAL APPEARANCE OF EXTRACTED TEETH AS VALIDATING CRITERION [J].
DOWNER, MC .
CARIES RESEARCH, 1975, 9 (03) :231-246
[4]   VARIATIONS AMONG DENTISTS IN RADIOGRAPHIC DETECTION OF OCCLUSAL CARIES [J].
ESPELID, I ;
TVEIT, AB ;
FJELLTVEIT, A .
CARIES RESEARCH, 1994, 28 (03) :169-175
[5]  
Firestone A R, 1994, Schweiz Monatsschr Zahnmed, V104, P719
[6]  
GRONDAHL HG, 1979, SWED DENT J, V3, P101
[7]  
GRONDAHL HG, IN PRESS DENT UPDATE
[8]   In vitro comparison of Kodak Ultra-speed, Ektaspeed, and Ektaspeed Plus, and Agfa M2 comfort dental x-ray films for the detection of caries [J].
Hintze, H ;
Christoffersen, L ;
Wenzel, A .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1996, 81 (02) :240-244
[9]   CLINICALLY UNDETECTED DENTAL-CARIES ASSESSED BY BITEWING SCREENING IN CHILDREN WITH LITTLE CARIES EXPERIENCE [J].
HINTZE, H ;
WENZEL, A .
DENTOMAXILLOFACIAL RADIOLOGY, 1994, 23 (01) :19-23
[10]   A LABORATORY EVALUATION OF EKTASPEED PLUS DENTAL-X-RAY FILM [J].
HORNER, K ;
RUSHTON, VE ;
SHEARER, AC .
JOURNAL OF DENTISTRY, 1995, 23 (06) :359-363