Suppression of physiological eye movement artifacts in functional MRI using slab presaturation

被引:12
作者
Chen, W
Zhu, XH
机构
[1] Ctr. for Magnetic Resonance Research, Radiology Department, Univ. of Minnesota Sch. of Medicine, Minneapolis, MN
[2] Ctr. for Magnetic Resonance Research, Radiology Department, University of Minnesota, Minneapolis, MN 55455
关键词
fMRI; presaturation; motion artifacts; eye movements;
D O I
10.1002/mrm.1910380407
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Reduction of image-to-image signal fluctuations and imaging artifacts is important for fMRI studies. The imaging artifacts caused by respiration, cardiac pulsation, and gross head motion and the suppression of these artifacts have been studied for many years. However, the artifacts caused by eye movement and their effects on fMRI mapping are not well known. It is demonstrated in this report that involuntary eye movements during resting conditions can cause substantial signal fluctuations in the phase-encoding direction even for a fast echo-planar imaging sequence. An oblique slab presaturation technique is proposed for saturating the magnetization of eyes and suppressing the artifacts from eye movements with minimal signal loss of other brain tissues. The results show that the technique significantly reduces signal fluctuations and improves fMRI reliability for mapping functional activation in the human brain.
引用
收藏
页码:546 / 550
页数:5
相关论文
共 14 条
[1]   PROCESSING STRATEGIES FOR TIME-COURSE DATA SETS IN FUNCTIONAL MRI OF THE HUMAN BRAIN [J].
BANDETTINI, PA ;
JESMANOWICZ, A ;
WONG, EC ;
HYDE, JS .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (02) :161-173
[2]   ANALYSIS OF FLOW EFFECTS IN ECHO-PLANAR IMAGING [J].
BUTTS, K ;
RIEDERER, SJ .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (03) :285-293
[3]  
CHEN W, 1995, P SMR 3 ANN M NIC, P747
[4]  
Chen W, 1995, P SMR 3 ANN M NIC, P1016
[5]   THEORETICAL ASPECTS OF MOTION SENSITIVITY AND COMPENSATION IN ECHO-PLANAR IMAGING [J].
DUERK, JL ;
SIMONETTI, OP .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (06) :643-650
[6]   RETROSPECTIVE ESTIMATION AND CORRECTION OF PHYSIOLOGICAL FLUCTUATION IN FUNCTIONAL MRI [J].
HU, XP ;
LE, TH ;
PARRISH, T ;
ERHARD, P .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (02) :201-212
[7]  
LUO Y, 1995, P SMR 3 ANN M NIC, P1017
[8]   MULTI-PLANAR IMAGE-FORMATION USING NMR SPIN ECHOES [J].
MANSFIELD, P .
JOURNAL OF PHYSICS C-SOLID STATE PHYSICS, 1977, 10 (03) :L55-L58
[9]   BRAIN MAGNETIC-RESONANCE-IMAGING WITH CONTRAST DEPENDENT ON BLOOD OXYGENATION [J].
OGAWA, S ;
LEE, TM ;
KAY, AR ;
TANK, DW .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1990, 87 (24) :9868-9872
[10]  
PREVIC FH, 1996, 26 ANN M SOC NEUR WA, P1857